background image

1

 

Nove

mber 

20

2

1

EM3500FM 280kg Electromagnetic 

Lock Installation Manual

 

Introduction:

 

The EM3500FM is a 280kg flush mount single magnetic lock.

 

 

The 

Lock Status Switch (LSS) 

indicates if the lock is powered and the magnetic bond is active using a Hall 

Effect crystal. The output is an onboard relay, 

the the output requires the lock to be powered

.

Wiring and Power input requirements

:

 

12 VDC

 

0.42 A max

 

24 VDC

 

0.21 A max

 

The (+) lead of the Power Source is connected to RED lead of the PCB and the (

-

) lead is connected to BLACK 

lead of the PCB. The operating switch or controlling contacts must be installed between the power source and 
the Magnetic Lock to reduce operating time of the magnetic lock to a minimum.

 

Dip switch settings: 

 

Switch positions 1 and 2 to ON and switch position 3 to OFF for 12 VDC operation. 
Switch position 3 to ON and switch positions 1 and 2 to OFF for 24 VDC operation 

Installation Tips

 

Armature Plate must remain flexible 

-

 the armature plate must be remained movable to allow surface alignment 

with the magnet face. The magnetic lock will lose holding force without this floating alignment.

 

Do not trim the rubber washer mounted on the head of the armature center bolt. Trimming rubber washers will ad-
versely affect the release of the armature plate from the magnetic lock.

 

Important Safety Requirements

 

Apply thread

-

locker glue (e.g. Loctite) to the thread of the Armature

-

Plate

-

Fixing Screw (Allen

-

Screw) to prevent from 

becoming loose.

 

Locks should be inspected at regular intervals to ascertain the safety functionality.

 

The supplied Allen screws cater for maximum door thickness of 45mm.

 

Отзывы: