Страница 1: ...MEA 2000 network LowranceNet All Lowrance NMEA 2000 capable devices are either NMEA 2000 certified or certification is pending CAUTION Installing LowranceNET NMEA 2000 devices is significantly different from installing earlier Lowrance components without NMEA 2000 features You should read all of the installation instructions before proceeding Decide where you want to install all components before ...

Страница 2: ...work or it WILL NOT function The NMEA 2000 red female to blue female adapter cable allows users to add red connector devices to a blue connector network Tools and Supplies Your EP sensor packs with a T connector needed to attach it to a LowranceNET NMEA 2000 network If this is the first sensor you are connecting you may also need a one time purchase of a LowranceNET Node Kit The following tools an...

Страница 3: ...ssure level is exceeded you not only risk damaging the EP 90R but could also suffer bodily injury Pitot Tube Water Speed We recommend installing the EP 90R near the boat s original speedometer NOTE If your engine does not have a speedometer hose you will have to purchase a pitot tube kit to use the EP 90R Pressure sensor For pitot tube installation instructions refer to your pitot tube installatio...

Страница 4: ...ine Water Pressure Fuel Pressure and Transmission Oil Pressure NOTE Make sure the pressure hose has enough slack to be attached to the pressure sensor when the EP 90R is connected to the NMEA 2000 backbone 1 Slide the Atmospheric Engine Boost Engine Oil Engine Water Fuel or Transmission Oil pressure hose onto the EP 90R hose barb attachment Attach a zip tie or hose clamp at the base of the hose ba...

Страница 5: ...he sockets on the sides and attaching any network device to the bottom of the T Staying with the previous phone wiring example T connectors on the backbone are the equivalent of phone jacks spread throughout a house To pick up a phone and be able to hear a conversation from another phone in the house both phones have to be connected to the main phone line In similar fashion only sensors and displa...

Страница 6: ...ector Adding a Network Node You can add a node to any existing connection anywhere along the network backbone This connection could be between a T connector and a terminator between two T connectors between a T connector and a backbone extension cable or between two extension cables Wherever you want to add the new node separate the sockets of the existing connection and install the T connector be...

Страница 7: ...Information For more information on creating or expanding a network refer to the NMEA 2000 network setup booklet part number 988 0154 173 which came packed with this document Existing network node Attach terminator at end of bus Use T connector or double T connector to add device to bus maintaining linear architecture Backbone cable to rest of bus Devices connect to double T connector ...

Страница 8: ...8 Notes ...

Страница 9: ...rst time you have turned on your LMF 200 you will have to complete Boat Setup before you will be able to configure your pressure sensor To execute Boat Setup 1 With Boat Setup highlighted on the screen press MENU The Boat Setup menu will appear allowing you to select an engine tank configuration that matches the number of engines and fuel tanks on your vessel Boat Setup options include 1 En 1 Tk 1...

Страница 10: ...ollowing data types Pitot Speed PTT S Water Pressure WTR P Engine Oil Pressure Eng O P Fuel Pressure FUL P Boost Pressure BST P Transmission Oil Pressure Trn O P and Atmospheric Pressure ATM P To configure the EP 90R 1 Press MENU select SYSTEM SETUP and press MENU 2 Highlight BUS DEVICES and press MENU Select an unconfigured pressure sensor UNCFG PRES and press MENU The following message will appe...

Страница 11: ...nd press MENU The Select Engine menu will appear with up to three options If your unit is set to a single tank configuration or if you chose Pitot Speed or Atmospheric Pressure you will be directed to the Bus Devices list 4 Select the desired engine and press MENU You will be taken back to the Bus Devices list Displaying Pressure Sensor Data You can display pressure data on the Gauge Single Digita...

Страница 12: ...UP and DOWN keys to display it on the screen 2 Press MENU select CUSTOMIZE and press MENU 3 Highlight PTT S Pitot Speed WTR P Engine Water Pressure ENG O P Engine Oil Pressure FUL P Fuel Pressure BST P Boost Pressure TRN O P Transmission Oil Pressure or ATM P Atmospheric Pressure and press MENU If your unit is configured for multiple tanks the Select Engine menu will appear with up to three option...

Страница 13: ... will appear with up to three options If your unit is configured for one engine or if you chose Pitot Speed or Atmospheric Pressure you will be directed back to the main display 5 Select the desired engine and press MENU You will be taken back to the main display To customize Fuel Manager page 1 After the Fuel Manager page has been added to the page screen rotation use the UP and DOWN keys to disp...

Страница 14: ...EVICES and press MENU 3 Select the desired pressure sensor and press MENU Highlight WRNING TRHLD and press MENU 4 Use the UP and DOWN keys to select the desired PSI level Depress the DOWN key to turn off a warning threshold The threshold will be set to Off by default 5 When the threshold is set to the desired level press MENU Reset The reset command switches pressure sensor settings alarms and con...

Страница 15: ...e 1 Eng 1 Tank 1 Eng 2 Tank 2 Eng 1 Tank 2 Eng 2 Tanks 3 Eng 1 Tank or 3 Eng 3 Tanks 2 Use the UP and DOWN keys to select the engine tank configuration that applies to your vessel and press ENTER After setting the engine tank configuration the Tank Size menu will appear with up to three options Port Tank Center Tank and Starboard Tank depending on the engine tank configuration you chose If you sel...

Страница 16: ...e and Atmospheric Pressure To configure the EP 90R 1 Press MENU select SYSTEM SETUP and press ENTER 2 Highlight BUS DEVICES and press ENTER Select an unconfigured pressure sensor and press ENTER The following message will appear Press Enter to Configure Pressure Snsr 3 Select PITOT SPEED ENG BST PRESS ENG OIL PRESS ENG WTR PRESS FUEL PRESSURE TRNS OIL PRESS or ATM PRESSURE and press ENTER 4 The Se...

Страница 17: ...ages Page Screen Rotation The Page Screen Rotation consists of multiple pages that have been set up for display Once pages have been added to the page screen rotation they can be set to scroll across the screen automatically or manually Use the ENTER and EXIT keys to manually scroll pages across the screen Pressing the ENTER key moves the scroll in one direction Pushing the EXIT key moves the scro...

Страница 18: ... Devices list 5 Select the desired engine and press ENTER You will be taken back to the Bus Devices list Press EXIT repeatedly to return to the main display To customize Dual Analog page 1 Make sure the Dual Analog page has been added to the page screen rotation 2 Use the ENTER and EXIT keys to scroll the Dual Analog page onto the main display 3 Press MENU use the UP and DOWN keys to select CUSTOM...

Страница 19: ...to the main display To customize Single Digital page 1 After the Single Digital page has been added to the page screen rotation use the ENTER and EXIT keys to display it on the main screen 2 Press MENU use the UP and DOWN keys to select CUSTOMIZE and press ENTER The data menu will appear 3 Highlight PITOT SPEED ENG BST PRESS ENG OIL PRESS ENG WTR PRESS FUEL PRESSURE TRNS OIL PRESS or ATM PRESSURE ...

Страница 20: ...ht PITOT SPEED ENG BST PRESS ENG OIL PRESS ENG WTR PRESS FUEL PRESSURE TRNS OIL PRESS or ATM PRESSURE and press ENTER The Select Engine menu will appear with up to three options If your unit is set to a single engine configuration or if you chose Pitot Speed or ATM Pressure you will be taken back to the Position menu 6 Select the desired engine and press ENTER You will be directed to the Position ...

Страница 21: ...SI range and press ENTER Warning Threshold When you set a Warning Threshold for a pressure sensor a pop up window will appear and an alarm will sound when pressure exceeds a preset pressure level of your choosing NOTE Warning Thresholds may be set to monitor Boost Pressure Engine Water Pressure Oil Pressure Fuel Pressure and Transmission Oil Pressure To set a warning threshold 1 Press MENU select ...

Страница 22: ...hlight BUS DEVICES and press ENTER 3 Select the desired pressure sensor and press ENTER 4 Highlight RESET VALUES and press ENTER The following message will appear Press Enter to Reset Values 5 You will be taken back to the Bus Devices list Press EXIT repeatedly to return to the main display ...

Страница 23: ...me NMEA 2000 related functions Bus Setup Selecting Bus Setup from the NMEA 2000 or Networking menu will open the Bus Configuration menu giving you access to the Engine Tank Configuration menu and the NMEA 2000 Devices list The list located in the top half of the Bus Configuration menu shows all devices connected to the network The Engine Tank Configuration menu is located in the bottom half of the...

Страница 24: ...agement NMEA 2000 Alarms Waypoint Sharing and Backlight Synchronization Choose BUS SETUP and press ENTER 3 Select ENGINE TANK CONFIG and press ENTER which will open the Engine Tank Configuration menu with the following configuration options 1 Engine 1 Tank 1 Engine 2 Tanks 2 Engines 1 Tank 2 Engines 2 Tanks 3 Engines 1 Tank 3 Engine 3 Tanks and Unconfigured Bus 4 Choose the configuration that matc...

Страница 25: ... to return to the main display EP 90R Pressure Sensor Configuration The Location and Pressure Type menus will be used when configuring you EP 90R You can also change the sensor s Device Name Device Name You can change how your pressure sensor will be displayed on your unit s NMEA 2000 Devices list by inputting a customized device name in the Device Name dialog box NOTE Changing the Device Name onl...

Страница 26: ... disappears Press ENTER then press EXIT to return to the NMEA 2000 menu 5 Highlight the device and press ENTER The Device Configuration menu will open The device name will be reset to its default setting Press EXIT repeatedly to return to the main display To select Location 1 Press MENU twice select NMEA 2000 or NETWORKING and press ENTER A menu will appear with five options Bus Setup Fuel Managem...

Страница 27: ... device s configuration 6 Highlight YES and press ENTER Press EXIT repeatedly to return to the main display NOTE You can unconfigure your EP 90R by setting the Location and Pressure Type to Unknown You also can use the Restore Defaults command Restore Defaults The Restore Defaults command will reset your pressure sensor to default settings To restore default settings 1 Press MENU twice select NMEA...

Страница 28: ...aced in the Enabled Box 5 To set the PSI level for an alarm press to highlight VALUE and press ENT 6 Use the arrow keys to input the desired PSI and press ENTER Repeat Steps 3 4 to set the other alarm 7 Highlight SET CONFIGURATION and press ENTER to finalize alarm settings Press EXIT repeatedly to get back to the main display NOTE To turn off uncheck an alarm select its ENABLED BOX and press ENTER...

Страница 29: ...29 Notes ...

Страница 30: ...30 Notes ...

Страница 31: ...EMENT OR REFUND AS JUST DESCRIBED IS THE EXCLUSIVE REMEDY AVAILABLE TO YOU AGAINST US FOR ANY DEFECT MALFUNCTION OR NON CONFORMITY CONCERNING THE PRODUCT OR FOR ANY LOSS OR DAMAGE RESULTING FROM ANY OTHER CAUSE WHATSOEVER WE WILL NOT UNDER ANY CIRCUMSTANCES BE LIABLE TO ANYONE FOR ANY SPECIAL CONSEQUENTIAL INCIDENTAL OR OTHER INDIRECT DAMAGE OF ANY KIND Some states do not allow the exclusion or li...

Страница 32: ...for sonar and GPS products manufactured by Lowrance Electronics and Eagle Electronics To order Lowrance or Eagle accessories please contact 1 Your local marine dealer or consumer electronics store To locate a Lowrance dealer visit the web site www lowrance com and look for the Dealer Locator To locate an Eagle dealer visit the web site www eaglesonar com and look for the Dealer Locator Or consult ...