Lowenstein Medical 200-0902 Скачать руководство пользователя страница 14

10.  

EC-Declaration of conformity

- 12 -

Содержание 200-0902

Страница 1: ......

Страница 2: ......

Страница 3: ...ax and abdominal movement 5 3 1 6 Sensor for body position 5 3 1 7 Sensor for leg movement 5 3 1 8 Sensor for ECG 5 3 1 9 Sensor for Snoring external 5 3 1 10 Sensors for EEG EOG EMG 6 3 2 Preparing f...

Страница 4: ...thorax effort to fasten the MiniScreen Pro unit to the patient Flexible belt with integrated pressure transducer to record abdominal effort Battery charger Shoulder bag for storing the MiniScreen Pro...

Страница 5: ...more than one patient at any one time is not allowed Warning When applying sensors to the patient please ensure that no electrical line of the device is in contact with any other electrical conductive...

Страница 6: ...arties LM shall not be liable for damages arising from non observance of this instruction manual The actual guarantee and warranty condi tions in the LM terms of sale delivery are not exten dable 3 Re...

Страница 7: ...hing of the belts may result in poor signals and possible loss of data 3 1 6 Sensor for body position The position sensor integrated in the MiniScreen Pro displays information related to the patient s...

Страница 8: ...switch the unit on before going to bed by sliding the switch to the right 7 The MiniScreen Pro is now ready for use The unit can now be disconnected from the PC Note remove cable by pulling on the plu...

Страница 9: ...onnection tab followed by Read measurement from device or select the following tab button 3 4 Online Measurements Inpatient Please adhere to the following steps when perfor ming an online measurement...

Страница 10: ...orage are between 5 C and 45 C The maximal humidity may not exceed 95 condensation has to be avoided 5 Evaluation software for PC 5 1 Installing the software To install the MiniScreen Pro software pla...

Страница 11: ...ly on the patient and remove any nail polish that may be present A small red light should be present in the sensor when the finger is inserted If the light doesn t switch on when the sensor is applied...

Страница 12: ...metric measurement and light Intensity display CPAP Bi level Differential pressure measurement directly on CPAP mask Measurement range 0cmH2O 45cmH2O 5 Leg movement Two leg sensors EMG for measurement...

Страница 13: ...4 Information 3 Installing the software 8 Leg movement 5 Maintenance 8 Optical isolator 3 Pacemaker 3 Position sensor 5 Preparing for measurement 6 Pressure pads 5 Safety related information 3 Selecti...

Страница 14: ...10 EC Declaration of conformity 12...

Страница 15: ......

Страница 16: ......

Отзывы: