Prevent fluids or other foreign objects from inside of the UPS system.   

 

The EPO and USB circuits are an IEC 60950-1 safety extra low voltage (SELV) circuit. This circuit must 
be separated from any hazardous voltage circuits by reinforced insulation.  

 1-5. Maintenance, service and faults  

 

The  UPS  system  operates  with  hazardous  voltages.  Repairs  may  be  carried  out  only  by  qualified 
maintenance personnel.   

 

Caution - 

risk of electric shock. Even after the unit is disconnected from the mains (building wiring 

outlet), components inside the UPS system are still connected to the battery and electrically live and 
dangerous.   

 

Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that 
no current is present and no hazardous voltage exists in the terminals of high capability capacitor such 
as BUS-capacitors.   

 

To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing the 
battery  

 

Only persons are adequately familiar with batteries and with the required precautionary measures may 
replace batteries and supervise operations. 

Unauthorized persons must be kept well away from 

the batteries.  

 

 

Caution -

 risk of electric shock. The battery circuit is not isolated from the input voltage. Hazardous 

voltages may occur between the battery terminals and the ground. Before touching, please verify that 
no voltage is present!   

 

Caution - 

Do not dispose of batteries in a fire. The batteries may explode.   

 

Caution -

 Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may 

be toxic.  

 

Batteries may cause electric shock and have a high short-circuit current. Please take the precautionary 
measures specified below and any other measures necessary when working with batteries:   

a)

 

Remove watches, rings, or other metal objects.  

b)

 

Use tools with insulated handles.  

c)

 

Wear rubber gloves and boots.  

d)

 

Do not lay tools or metal parts on top of batteries.  

e)

 

Disconnect charging source and load prior to installing or maintaining the battery. 

f)

 

Remove  battery  grounds  during  installation  and  maintenance  to  reduce  likelihood  of  shock. 
Remove the connection from ground if any part of the battery is determined to be grounded.  

 

When changing batteries, install the same number and same type of batteries or battery packs.   

 

Please replace the fuse only with the same type and amperage in order to avoid fire hazards. 

 

Do not dismantle the UPS system.  

Only for 100/110/115/120/125 VAC system: 

 

 

NOTE: 

This equipment has been tested and found to comply with the limits for a Class A digital 

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instruction manual, may cause harmful interference to 
radio communications. Operation of this equipment in a residential area is likely to cause harmful 
interference in which case the user will be required to correct the interference at his own expense.  

 

WARNING: 

Changes or modifications not expressly approved by the party responsible for compliance 

could void the user's authority to operate the equipment.  

 

Содержание UPS9LI-1500

Страница 1: ...Online Uninterruptible Power Supply w Lithium Battery User Manual Lowell Models UPS9LI 1500 UPS9LI 2000 UPS9LI 3000 2022 Lowell Manufacturing Company Version 1 0 8 4 22...

Страница 2: ...View 3 2 2 Operating Principle 4 2 3 Install the UPS 4 2 4 Set up the UPS 5 2 5 Battery Replacement 7 3 Operations 9 3 1 Button Operation 9 3 2 LCD Panel 9 3 3 Audible Alarm 11 3 4 LCD display wording...

Страница 3: ...tested CE marked or UL marked for 100 110 115 120 125 VAC models mains cable e g the mains cable of your computer to connect the UPS system to the building wiring outlet shockproof outlet Please use o...

Страница 4: ...e skin and eyes It may be toxic Batteries may cause electric shock and have a high short circuit current Please take the precautionary measures specified below and any other measures necessary when wo...

Страница 5: ...place for future use 2 1 Rear panel view NEMA Type 1 5K 2K 3K 1 Programmable outlets connect to non critical loads 2 Output receptacles connect to mission critical loads 3 AC input 4 Network Fax Modem...

Страница 6: ...low steps to re connect battery wires first Remove front panel Connect the AC input and Put the front panel back re connect battery wires on the unit This UPS can be either displayed on the desk or mo...

Страница 7: ...PS input connection Plug the UPS into a two pole three wire grounded receptacle only Avoid using extension cords For 100 110 115 120 125 127VAC models The power cord is attached to the UPS The input p...

Страница 8: ...ions Step 4 Network connection Network Fax Phone surge port Connect a single modem phone fax line into surge protected IN outlet on the back panel of the UPS unit Connect from OUT outlet to the equipm...

Страница 9: ...starts the monitoring software will appear as an orange plug icon located in the system tray near the clock 2 5 Battery Replacement When the icons of and are flashing in LCD display and alarm is sound...

Страница 10: ...8...

Страница 11: ...y Press this button to confirm selection in UPS setting mode Select Button Switch LCD message Press this button to change the LCD message for input voltage input frequency input current battery voltag...

Страница 12: ...equency load current and load percent k kilo W watt V voltage A ampere percent centigrade degree Hz frequency Load Information Indicates the load level by 0 24 25 49 50 74 and 75 100 Indicates overloa...

Страница 13: ...Display content Meaning ENA Enable DIS Disable ESC Escape HLS High loss LLS Low loss AO Active open AC Active close EAT Estimated autonomy time RAT Running autonomy time SD Shutdown OK OK ON ON BL Ba...

Страница 14: ...disable Interface Setting Parameter 2 Enable or disable converter mode You may choose the following two options CF ENA converter mode enable CF DIS converter mode disable Default 03 Output frequency...

Страница 15: ...120 Models the setting voltage in parameter 3 is from 3V to 12V of the nominal voltage Default 6V 06 Bypass enable disable when UPS is off Interface Setting Parameter 2 Enable or disable Bypass functi...

Страница 16: ...low loss point from 55Hz to 59Hz Default 57 0Hz 09 Programmable outlets enable disable Interface Setting Parameter 2 Enable or disable programmable outlets ENA Programmable outlets enable DIS Programm...

Страница 17: ...it will activate EPO function with Pin 1 and Pin 2 in open status AC Active Close When AC is selected as EPO logic it will activate EPO function with Pin 1 and Pin 2 in close status 17 Site fault dete...

Страница 18: ...ble range or power failure the UPS will backup power from battery and alarm is sounding every 5 seconds Bypass mode When input voltage is within acceptable range but UPS is overload UPS will enter byp...

Страница 19: ...Sounding every 2 seconds Over temperature Sounding every 2 seconds Charger failure Sounding every 2 seconds Battery fault Sounding every 2 seconds At this time UPS is off to remind users something wr...

Страница 20: ...teries are connected well Fault code is shown as 27 on LCD display and alarm is continuously sounding Battery voltage is too high or the charger is fault Contact your dealer Fault code is shown as 28...

Страница 21: ...load is no longer supplied by power Contact your dealer Battery backup time is shorter than nominal value Batteries are not fully charged Charge the batteries for at least 5 hours and then check capac...

Страница 22: ...eplaced In this case please contact your dealer Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance...

Страница 23: ...ty PHYSICAL Dimensions W x D x H in 17 2 x 15 1 x 3 5 17 2 x 19 x 3 5 17 2 x 23 8 x 3 5 Weight lbs 25 6 33 5 45 2 Line cord 6 ft 5 15P 6 ft 5 20P 6 ft L5 30P Receptacles 8 NEMA 5 15R 8 NEMA 5 15 20R L...

Страница 24: ...Vac input 1350VA 1040W 13 5A 100Vac input UPS9LI 2000 100 125Vac 50 60Hz 16A 1 100 110 115 120 125Vac 50 60Hz 1 2000VA 1800W 16A 125Vac input 2000VA 1800W 16 7A 120Vac input 2000VA 1740W 17 4A 115Vac...

Страница 25: ...well Manufacturing Company approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limi...

Отзывы: