![Lowara e-LNEEE Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/lowara/e-lneee/e-lneee_installation-operation-and-maintenance-manual_1942484038.webp)
en
– Original instructions
38
code Description
Cause
Remedy
E04
Rotor blocked
Motor stall
Loss of rotor synchronism or
rotor blocked by external
materials
Check that there are no foreign bodies
preventing the pump from turning
Stop the pump for 5 minutes and then start it
again
If the problem continues, contact Xylem or the
Authorised Distributor
E05
EEPROM Data
memory error
EEPROM Data memory corrupted Stop the pump for 5 minutes and then restart it
again; if the problem continues, contact Xylem or
the Authorised Distributor
E06
Grid voltage error
Voltage supply out of operating
range
Check:
the voltage
the connection of the electric system
E07
Motor winding
temperature error
Motor thermal protection trip
Check for impurities near the impeller and rotor.
Remove them if necessary
Check the conditions of installation,and the
water and air temperature
Wait for the motor to cool down
If the error persists, stop the pump for 5
minutes and then start it again
If the problem continues, contact Xylem or the
Authorised Distributor
E08
Power module
temperature error
Frequency converter thermal
protection trip
Check the conditions of installation,and the air
temperature
E09
Generic hardware
error
Hardware error
Stop the pump for 5 minutes and then restart it
again; if the problem continues, contact Xylem or
the Authorised Distributor
E10
Dry-run error
Dry run detection
Check if there are any leaks in the system and refill
the system
E11
LOW error
Lack of water detection (if P48=
ERR)
Check the water level in the system
E12
Pressure sensor
error
Missing pressure sensor (not
present in ACT mode)
Check the condition of the sensor connection
cables
E14
Low pressure error
Pressure below minimum
threshold (not present in ACT
mode)
Check the settings of parameters P45 and P46
E15
Loss of phase error
One of the three power supply
phases is missing (three-phase
versions only)
Check the connection to the power supply network
E31
Pressure sensor
error 1
No pressure sensor 1 detected
Check the condition of the sensor connection
cables
E32
Pressure sensor
error 2
No pressure sensor 2 detected
Check the condition of the sensor connection
cables
See also Par. 6.3.2 and Par. 6.4.3.