LOVATO ELECTRIC PMVFUPS01 Скачать руководство пользователя страница 2

2

 

 

 

INDEX 
 
INTRODUCTION ................................................................................................................. 2 

DESCRIPTION ................................................................................................................... 2 

FRONTAL INDICATIONS ....................................................................................................... 2 

INSTALLATION ................................................................................................................... 2 

MECHANICAL DIMENSIONS [mm] 

± WIRING DIAGRAMS ............................................................... 2 

SUGGESTED LOVATO ELECTRIC CONTACTORS ....................................................................... 3 

TECHNICAL CHARACTERISTICS ............................................................................................ 4 

 

INDICE 
 
INTRODUZIONE ................................................................................................................. 2 

DESCRIZIONE ................................................................................................................... 2 

INDICAZIONI FRONTALI ....................................................................................................... 2 

INSTALLAZIONE................................................................................................................. 2 

DIMENSIONI MECCANICHE [mm] 

± SCHEMI DI COLLEGAMENTO ................................................... 2 

CONTATTORI LOVATO ELECTRIC SUGGERITI .......................................................................... 3 

CARATTERISTICHE TECNICHE.............................................................................................. 4 

 

0B

INTRODUCTION

 

The CEI 0-21 and CEI 0-16 standards require an auxiliary power supply that supports the interface 
protection (IP), the interface switch (IS) and a back-up switch (if any) in the event of a power failure. 
PMVFUPS01 guarantees the necessary energy by accumulating it in capacitors, thus avoiding the 
use of batteries which require maintenance.

 

7B

INTRODUZIONE 

Le norme CEI 0-21 e CEI 0-

ULFKLHGRQRXQ¶DOLPHQWD]LRQHDXVLOLDULDFKHsostenga per almeno 5 

secondi la protezione di interfaccia (PI), il dispositivo di interfaccia (DDI) ed un 
HYHQWXDOHULQFDO]RLQFDVRGLPDQFDQ]DGHOODUHWHGLDOLPHQWD]LRQH309)836JDUDQWLVFHO¶HQHUJLD
necessaria accumulandola in condensatori, evitando 

TXLQGLO¶XWLOL]]RGL batterie che richiedono 

manutenzione. 

1B

DESCRIPTION 

±  power supply: 230VAC, 50Hz 
±  output voltage: 230VAC, 50Hz 
±  output power: 250VA 
±  storable energy: 200Ws 
±  accumulation time: 15s 
±  9U modular housing 
±  working temperature: -5 ... + 55 ° C 
±  degree of protection IP20. 
 

8B

DESCRIZIONE 

±  alimentazione: 230VAC, 50Hz 
±  tensione di uscita: 230VAC, 50Hz 
±  potenza di uscita: 250VA 
±  energia accumulabile: 200Ws 
±  tempo di accumulo: 15s 
±  contenitore modulare 9U 
±  temperatura di esercizio: -5...+55°C 
±  grado di protezione IP20.

 

2B

FRONTAL INDICATIONS 

9B

INDICAZIONI FRONTALI 

 

 

 

 
 

 
 
 

 

 

 

 
 
 
 

 

Attention! Voltage on terminals even if the device is switched off. The device remains 
charged approximately 2 hours without power supply. A red LED close to CAP terminal 
indicates the voltage presence. 

 

Attenzione!! Tensione presente sui terminali anche a dispositivo spento. Il dispositivo 
rimane carico approssimativamente per 2 ore senza alimentazione. Un LED rosso vicino al 
morsetto CAP indica la presenza di tensione.

 

3B

INSTALLATION 

±  Connect the auxiliary power supply of the interface protection (IP) to the "IP power supply" terminal. 
±  Connect the coil of the interface switch (ISWRWKH³,6´WHUPLQDOLQVHULHVZLWKWKH relevant control 

contact of the IP. 

±  Connect the coil of the backup device to the "Backup" terminal in series with the relevant control 

contact of the IP. 

±  Leave the CAP terminal not connected. 
±  Connect the auxiliary power supply of PMVFUPS01
±  Fuses are internally installed for the auxiliary power supply and for the power output. 
±  The device requires 15s to be charged again. 

10B

INSTALLAZIONE 

±  &ROOHJDUHO¶DOLPHQWD]LRQHDXVLOLDULDGHOODprotezione di interfaccia (PI) DOWHUPLQDOH³,3SRZHUVXSSO\´

 

±  Collegare la bobina del disSRVLWLYRGLLQWHUIDFFLD'',DOWHUPLQDOH³,6´LQVHULHDOrelativo contatto di 

comando della PI.

 

±  &ROOHJDUHODERELQDGHOGLVSRVLWLYRGLULQFDO]RDOWHUPLQDOH³%DFNXS´LQVHULHDOUHODWLYRFRQWDWWRGL

comando della PI.

 

±  Lasciare non collegato il terminale CAP.

 

±  &ROOHJDUHO¶DOLPHQWD]LRQHDXVLOLDULDGHO309)836

 

±  SonRSUHVHQWLIXVLELOLLQWHUQLVXOO¶DOLPHQWD]LRQHDXVLOLDULDHVXLPRUVHWWLGLXVFLWD

 

±  Il dispositivo richiede 15s di ricarica dopo ogni suo intervento.

 

 

4B

MECHANICAL DIMENSIONS [mm] 

± WIRING DIAGRAMS 

11B

DIMENSIONI MECCANICHE [mm] 

± SCHEMI DI COLLEGAMENTO 

                          

 

                

 

 
 

Alimentazione 

Power supply 

Alimentazione PI 

IP power supply 

Alimentazione DDI 

IS power supply 

Alimentazione Rincalzo 

Backup device power supply 

Bus DC 

DC bus 

LED segnalazione condensatori carichi 

Charged capacitor indication LEDs 

I6

5

3

 GB

 I

 06

 2

1

    

   

  

   

   

   

   

  

   

   

   

   

   

  

   

   

3

1

10

0

48

9

 

    

   

 

 

Отзывы: