R1912 AND R1918 MOTOR FOR USE WITH R1932 WALL TIMER EMITTER
Operating Instructions
KEY FEATURES
DC power supply with energy saving patented design, 7.4V 3000mAh Lithium
battery built-in (1.8Nm). 7.4V 2600mAh Lithium battery built-in (1.2Nm).
Setting limits by remote control. Up to 6 limits, including Upper/Lower limit and 4
intermediate limit positions.
433.92MHz Radio Control.
Short/Open Circuit Protection.
Automatic alarm buzzer for low battery, then the motor will enter into jog mode.
Patented helical gear design, noise level lowered to 30dB.
POWER SOURCE
THE CHARGING OPTIONS
Built-in Li-ion battery power supply. Recharged using an external charger. On a full charge can be
used for 3-6 months. Charging time is 6-8 hours.
DC8.4V Power Input
LEFT
RIGHT
DOWN
SET
Time Status
Battery Staus
UP
STOP
PROGRAM
CR2450 Battery
Weekday
Channel
1
2
3
4
5
6
REAR VIEW
SUN MON TUE WED FUR FRI SAT
PROGRAM / POWER BUTTON
CHARGE PORT
SETTING
THE BLIND
PROGRAM / POWER BUTTON
CHARGE PORT
MOTOR HEAD
WALL TIMER EMITTER
PROGRAM
POWER ON/OFF
THE BLIND
After switching off power the motor will not be able to receive remote signals.
Press the PROG button on the
motor head for 1 second until
the motor beeps once.
The motor is now ON.
Power ON
Press the PROG button on the
motor head for 7 seconds, the
motor will oscillate for 1 second.
After a long beep the
motor is now OFF.
Power OFF
PAIRING WALL EMITTER
Multiple controllers can be linked to one blind
Press the PROG button until
the motor oscillates
1
2
3
4
5
6
SUN MON TUE WED FUR FRI SAT
Press the UP button on the wall emitter once.
The blind oscillates. Test UP/STOP/DOWN
buttons once each
CHANGE DIRECTION
If there is a need polarity can be reversed.
Wait 30 seconds since last command.
1
2
3
4
5
6
SUN MON TUE WED FUR FRI SAT
Press and hold the STOP
button for 5 seconds until
the blind oscillates.
1
2
3
4
5
6
SUN MON TUE WED FUR FRI SAT
Press the DOWN button
once. The blind oscillates to
signal the direction is changed.
LIMIT POSITION
1) .The first and second positions are Upper/Lower limit positions. The other four are inter
mediate positions.
2) .After the Upper/Lower limit positions are set, all the intermediate positions must be set between
the Upper and Lower limit.
3).The Upper and Lower limit position can be fine-tuned once set. The Upper Limit can only be
removed by deleting all the motor memory.
4) .Press the UP or DOWN button once and the motor will move to the next pre-set limit position.
When the upper position has been reached the UP button will be unresponsive. When the lower
position has been reached the down button will become unresponsive.
5) .Press and hold the UP or DOWN button until the indicator on the programmed channel flashes
twice, release, then the motor will move to the Upper or Lower limit position without stopping
at any intermediate position.
1
2
3
4
5
6
SUN MON TUE WED FUR FRI SAT
1
2
3
4
5
6
SUN MON TUE WED FUR FRI SAT
SETTING UPPER AND LOWER LIMIT
Once the limits are set the system will exit the command automatically.
Both limits must be set to exit mode.
The motor is now ON.
Press SET on the programmed
remote for 1 second.
1
2
3
4
5
6
SUN MON TUE WED FUR FRI SAT
Press UP to the desired upper
limit position then press STOP.
The motor oscillates once,
the upper limit is now set.
1
2
3
4
5
6
SUN MON TUE WED FUR FRI SAT
Press DOWN to the desired lower
limit position then press STOP.
Press SET for 1 second again.
Press SET to confirm
The motor will oscillate,
the lower limit is now set.
MOTOR HEAD
Press SET to confirm
WALL TIMER EMITTER
THE LAYOUT
LEFT/RIGHT: channel shift, current system time /working mode setting shift, days selection
UP/DOWN: motor direction changing, figures selection, channel selection
SET: long press 3s to get into setting mode, long press 3s to save setting
STOP: stop, change setting items in setting page, long press 3s to exit setting mode (won’t save setting)
The user can start to set timing point until the system time of the timer is set.
THE THIRD LIMIT POSITION
THE UPPER LIMIT POSITION
THE THIRD LIMIT POSITION
THE LOWER LIMIT POSITION
THE THIRD LIMIT POSITION
ALL THE
INTERMEDIATE LIMIT
POSITIONS MUST BE
SET BETWEEN THE
UPPER AND LOWER
LIMIT POSITIONS.
Issue: MAY20