KIT CONTENTS
4 VERIFACT Model A Microphones
Model IF-4 Audio Interface Adapter
Model AD-1 12Vdc power supply
Patch cables for connection to the audio inputs of
DVR’s, IP Network Cameras, Soundcards, etc. as listed
above (RCA to RCA and RCA to 3.5mm Mono adaptors)
(4) VERIFACT A
MICROPHONES
IF-4 AUDIO INTERFACE ADAPTER
AD-1 POWER SUPPLY
AD-1 POWER SUPPLY
DESCRIPTION
WIRING CONNECTIONS
ASK-4 #304 is a four zone audio monitoring system
designed for direct connection to a DVR, PC soundcard or
IP Network Camera. Model IF-4 Interface Adapter (usually
mounted near the recording device) receives the wiring from
the Verifact™ A Microphone, supplies power and drives the
audio signals into the DVR, IP Network Camera, Video
Server or PC Soundcard.
Distance between the Verifact A Microphone and Model IF-
4 Interface Adapter may be up to 1,000 ft.(305m) using
recommended wiring. Each output of the IF-4 has an audio
level control to increase or decrease the level of audio output
going to the receiving device.
2 Conductor
shielded
cable, 22
gauge with a 24 gauge drain wire
WIRING REQUIREMENTS
West Penn 452 or equivalent
MICROPHONE CONNECTIONS
Located at the bottom of the Verifact A microphone is a 3-pin terminal block marked A, B, and C.
A = 12Vdc power
B = Audio output of microphone
C = Ground
If using the recommended wiring (West Penn 452), connect as follows;
Red wire goes to terminal A of microphone
Black wire goes to terminal B of microphone
Bare wire goes to terminal C of microphone
After all microphones have been connected, bring the other end of the cable to the IF-4 location and connect each
microphone to the corresponding terminal block of the unit matching A to A, B to B, and C to C. Be sure to properly match
wire colors. If using cable from other manufacturers, color code may vary.
CONNECTIONS BETWEEN IF-4 AND DVR (OR OTHER AUDIO RECEIVING DEVICE)
Connect the RCA outputs of the IF-4 to the corresponding audio inputs of the receiving device. RCA and RCA to 3.5mm
mono cables are included in the kit.
AUDIO MONITORING SYSTEM
INSTALLATION AND OPERATING INSTRUCTIONS
ASK-4 #304
®
6955 VALJEAN AVE, VAN NUYS, CA 91406
PH: (818)994-6498 / FAX: (818)994-6458
/ www.louroe.com
®
®
®
®
®
®