WIRING CONNECTIONS BETWEEN MODEL TLM-CF SPEAKER/MICROPHONE AND AP-1TB
AUDIO BASE STATION
1) Connect one end of recommended cable to remote speaker/microphone (TLM-CF) as shown in Fig. 4. Connect wires
wrapped with overall shield to terminals “A”, “B”, and “C” of TLM-CF’s terminal block. When using sample cable,
connect
red
wire to terminal “A”;
black
wire to terminal “B” and
bare
wire to terminal “C”.
2) Connect the two speaker wires (twisted pair) green and white to
green
and
white
wires of TLM-CF’s 70V transformer.
Using wire nut connect
green
wire to
green
wire of TLM-CF’s 70V Transformer. Again, using wire nut connect
white
wire to
white
wire of TLM-CF’s 70V Transformer.
3) Connect the other end of the cable to AP-1TB
Mic 6-Pin Terminal Block [12]
. Make sure that wire connected to
terminal “A” of remote TLM-CF connects to terminal “A” of AP-1TB’s
Mic 6-Pin Terminal Block [12]
; wire connected to
terminal “B” of TLM-CF connects to terminal “B” of AP-1TB; “C” to “C”. Observe cable color coding. Terminal “P” of
AP-1TB is not used with this application. Used only when paralleling to a second AP-1TB.
4) For speaker connection, connect
green
speaker wire (positive) to
Mic 6-Pin Terminal Block [12]
terminal “SP”,
connect
white
speaker wire (ground) to “G”.
5) When a recording device is used (DVR,VCR,etc.) connect
Audio-OUT Jack [11]
to recorder’s Audio-IN Jack with the
dual RCA cable (supplied).
6) Connect
Audio-IN Jack [10]
to recorder’s Audio-OUT Jack with the remaining RCA plug.
INSTALLATION AND OPERATING INSTRUCTIONS
Page 5 of 8
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406
TEL (818) 994-6498
FAX
994-6458
website: www.louroe.com e-mail: [email protected]
(818)
®
INSTALLATION OF TLM-CF SPEAKER/MICROPHONE
Model TLM-CF is designed for mounting to a wall or flat surface. Included is a plastic backbox for surface mounting to a
wall. If flush mounting is needed, a 3 gang electrical box (not supplied) maybe used.
1) Drill an opening at top, bottom, side or back of backbox for passing wiring or connecting conduit.
Four small screws are supplied for attaching backbox to a wall.
2) Four screws are also supplied for attaching the TLM faceplate to the backbox. The plastic hole plugs must be place on
the screw holes of the faceplate to cover the screws.