INSTRUCTIONS FOR USE
Translation of the original instructions
20
TABLE OF ERRORS DUE TO THE GENERATOR (E1)
ERROR
NO.
DESCRIPTION
CAUSE
CORRECTIVE ACTION
E1
1
Too much current on the
hardware
1 - Use of unsuitable pots
2 - Inductance broken or defective
1 - Use a suitable pot
2 - Check the inductance
E1
2
No current on the inductor Connection interrupted
Reconnect the inductor
E1
3
Temperature on the IGBT
too high
Ventilation ducts obstructed, fan
clogged, IGBT sensor defective
Clean the ventilation ducts, clean the
fan, check that the fan rotates
correctly
E1
4
Temperature in the cooking
area too high or too low
1 - Pot empty
2 - Temperature sensor defective
3 - Power supply board defective
1 - Remove the pot, turn off the
appliance and wait a few minutes until
the cooking area has cooled down
2 - Replace the temperature sensor
3 - Replace the generator
E1
5
Control unit not functioning
1- Defective wiring
2 - The ID of the digital control is
defective
3 - Control unit defective
1 - Check the wiring of the control unit
2 - Turn off the generator, adjust the
DIP switch correctly
3 - Replace the control unit
E1
6
Temperature in the
electronics too high
Ventilation ducts obstructed, fan
clogged, temperature sensor
defective
Clean the ventilation ducts, clean the
fan, check that the fan rotates
correctly
E1
7
Winding temperature
1 - Winding temperature too high
2 - Temperature sensor defective
1 - Remove the pot, turn off the
appliance and wait a few minutes until
the cooking area has cooled down
2 - Replace the temperature sensor
E1
8
No mains phase
Insufficient quality of mains phase
distribution
Control the main power supply
E1
10
Communication error
No LIN or CAN-Bus, no connection
between the keyboard and generator
Disconnect the power supply mains
and check the connections
E1
11
Initialisation error
1 - No control unit connected
2 - The ID of the digital control is
defective
3 - Error during hardware initialisation
1 - Correctly connect the control unit
2 - Turn off the generator, correctly
regulate the DIP switch
3 - Wait, the device is reset every 30
sec. approx.
E1
13
Power supply mains
connection error
The mains voltage is too high or too
low
Check the mains connection
E1
14
Mains adaptor error
The mains voltage is too high or too
low
Check the mains connection
E1
15
Empty pot protection
1 - Mains error
2 - Pot empty
3 - Inductor temperature sensor
defective
1 - Turn off the appliance, wait a few
seconds and turn it back on
2 - Remove the pot, turn off the
appliance and wait a few minutes until
the cooking area has cooled down
3 - Replace the inductor temperature
sensor