Lotus H370 Petite Скачать руководство пользователя страница 4

 

 

      Pic.2                    

A: Holes used for fastening the insert to the base.                                          
B: Set screws for adjustment of the insert in relation to the base. 
C: Set screws for adjustment of the combustion champer in relation to the cabinet. 

 
 

Pic.2 

 

A: upper smoke turnplate-B: lower smoke turnplate-C: Skamol must be removed 
to gain access to the adjusting/fastening screws. 

 

The potential for the building-in of fireplace inserts is vast; they may be built into the 
wall, on the outside of the wall, and may be suspended on the wall. Building-in shall 
take place in connection with non-inflammable materials only. Virtually all 
installations are designed individually, and in all cases the distance to inflammable 
matter must meet the values stated below.  
 
By setup in connection with inflammable material, you must create a structure to the 
cassette by a steel frame and super isol plates (or plates of equal or better insulation), 
see example with minimum measurements. 
 

The Base 

The base must, of course, be firm and have adequate load-bearing capacity. This will 
usually pose no problem when assembling in an open fireplace. 
 
In case of an inflammable floor, the height of the foundation for the insert must be 
minimum 300mm. 

 

Содержание H370 Petite

Страница 1: ...Assembly and User Instructions Fireplace Insert Lotus H370 Petite Version 1 11 10 2012 ...

Страница 2: ......

Страница 3: ... to many European markets Lotus products are made to a fine Danish tradition serving its owners faithfully for years So once again congratulations on your new Lotus fireplace insert making for a warm and cosy beginning of an all new home life for you Fireplace Insert Assembly Before your new fireplace insert will be ready to exude warmth and a cosy atmosphere you should read these lines thoroughly...

Страница 4: ...wall Building in shall take place in connection with non inflammable materials only Virtually all installations are designed individually and in all cases the distance to inflammable matter must meet the values stated below By setup in connection with inflammable material you must create a structure to the cassette by a steel frame and super isol plates or plates of equal or better insulation see ...

Страница 5: ...ill usually be in order If it is a matter of a new building reference is made to any local regulations on fireproofing etc You may contact your chimney sweeper for clarification of any issues of doubt Wood stove data testing to EN 13 229 CE Model Flue gas Temperature at nominal Output KW Flue gas Mass flow g s Flue Pa Weight Kg Distance to inflammable material Distance behind Structure mm Next to ...

Страница 6: ...eys or chimneys made of ceramic units as their inside surface will frequently be rough and will offer resistance All joints and connecting points shall of course be tight and the chimney shall provide a draught of min 1 2mm water head 12 Pa Register If your chimney has a register this must have a forced opening of min 20cm2 Assembly of Smoke Turn Plates The illustration below shows how to place th...

Страница 7: ...one material This plate should be big enough to reach min 50cm in front of the fireplace insert and 30 cm at each side of the fireplace opening Chimney Sweeper Once your new fireplace insert has been assembled do make a point of registering the installation with the chimney sweeper For one thing the installation is to be inspected and the chimney will also have to be swept by the chimney sweeper i...

Страница 8: ...tart all over from item 4 Refuelling on to a low fire bed If there is insufficient burning material in the firebed to light a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable period If there are too few embers in the fire bed add suitable kindling to prevent ex...

Страница 9: ...ace Insert It is recommended that the maintenance of your stove be performed by a qualified service engineer and that only spares recommended by the manufacturer be used Packings may look neat but they will collapse in the heat and will thus lose their ability to keep the fireplace insert tight Packings should be replaced as required since good combustion and a clean pane will very much depend on ...

Страница 10: ... insert and chimney by way of shining soot and tar encrustation At worst this may cause a chimney fire If your firewood is far too dry it will burn too quickly Frequently the gases in the wood will be released at a rate quicker than they will burn and part of these will in unburned condition pass up through the chimney This will also cause a lower degree of utilization and will harm the environmen...

Страница 11: ...nstructions have been followed In particular the conditions round the chimney may cause trouble Are the diameter and the height OK is it tight and are flues and transitions tight A chimney sweeper may have to be contacted to remedy the problem as the chimney may be blocked Smelling of smoke and soot This may be due to wind down draught in the chimney and would generally occur in particular wind di...

Страница 12: ...Fireplace Insert H370 Petite ...

Страница 13: ......

Страница 14: ...ith the directions for use and if deficiencies or similar are aimed to be are remedied by a person not authorized by Lotus Heating Systems A S This warranty does not cover damage caused by inappropriate non expert incompetent use of the stove If a product is returned to Lotus Heating Systems A S and the damage subsequently turns out not to be covered by this warranty any costs incurred shall be in...

Страница 15: ......

Отзывы: