background image

INSTALLATION

Translation of the original instructions

13

valve and fast-closing valve. Once installation is complete, make sure that there are no gas leaks from the
fittings; to do this, do not use a naked flame but substances that do not cause corrosion, such as solutions of
soapy water or leak detectors. All our appliances are subjected to detailed examination: the type of gas,
pressure in use and the pertinent category are indicated on the data plate (see attachment).
 

Note

 

The year of construction of the appliance is indicated under "N" on the data plate. The first 2 digits
indicate the year of construction.

 

·

THERMAL OUTPUT CONTROL

 
The appliances must be checked in order to verify that their thermal output is correct:
 

·

Thermal output is indicated on the appliance's data plate;

·

Firstly, make sure that appliance is set for the type of gas used and then make sure that the indication on

the data plate matches this gas. To adapt the appliance to another type of gas, make sure that the type of
gas in question complies with the information in this instruction manual.

 

Warning

 

Pressure is measured with a pressure gauge (minimum resolution of 0.1 mbar) mounted on
the appropriate socket. Remove the M6 locking screw and insert the pressure gauge tube.
The test must be performed with all the burners on the appliance switched on and all the
appliances in the same line switched on. After taking the measurement, replace the screw,
firmly tighten and check the seal.

 

Liquid gas connection G30 / G31
 
The liquid gas connection pressure is 30 mbar for butane and 37 mbar for propane. Check the data plate,
measure the pressure and verify that the description of the nozzle installed matches the information provided
by the manufacturer.
 
Methane gas connection H G20
 
The methane gas connection pressure is 20 mbar. Check the data plate, measure the pressure and verify
that the description of the nozzle installed matches the information provided by the manufacturer.
 

·

CHECKING THE PRIMARY AIR FOR MAIN BURNERS AND PILOT NOZZLE

 
For burners equipped with air adjustment, set the adjustable bushing and lock it with a screw. The "Burner
technical data" table shows approximate values for the "h" parameter (primary air). The primary air flow
volume must be adjusted to avoid a flame cut-off when the burner is cold and a flame blowback when the
burner is hot. The pilot air adjustment is set testing for the gas which the appliance will use. In the event of
conversion to other types of gas, adjust the air using the adjustment bush until the pilot flame is steady and
has an intense blue colour.
 
Disposition for conversion and installation for other types of gas:
 
Our appliances are tested and set for liquid gas or natural gas (see attached data plate). Conversion or
adaptation to another type of gas must be performed by a specialist technician. The nozzles for the various
types of gas are contained in a bag included in the supply and are marked in hundredths of mm (see
"Burners" technical data table).
 

·

INSTRUCTIONS FOR EVACUATING EXHAUST GASES

 

Содержание F13T-94G

Страница 1: ...tions GAS FRYERS FOR PROFESSIONAL USE F18 94G F2 18 98G F25 94G F2 25 98G F13T 94G F2 13T 98G F2 8 94G F2 8T 94G Model LIBR ISTR F90G Code 563008802 Review 1 Edition date 10 09 2018 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Страница 2: ...ackaging 11 3 3 Mechanical installation 11 3 4 Electrical gas connections 11 4 BURNERS TECHNICAL DATA TABLE ITGB 16 5 INSTRUCTIONS FOR USE 17 5 1 General information 17 5 2 Switching the pilot burner on 17 5 3 Starting the main burner and adjusting the temperature 17 5 4 Switching the main burner off 18 5 5 Switching the appliance off 18 5 6 Safety thermostat 18 5 7 Emptying the tank 18 5 8 Top ap...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 F 9G A Data Plate B Electrical connection C Gas connection ...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 F T A Data Plate C Gas connection ...

Страница 5: ... of the original instructions 5 1 2 Components FIG B 1 Thermostat knob 2 Green indicator light 3 White indicator light 4 Hole for indicator light 5 Oil drain 6 Drain extension 7 Power button 8 Valve 9 Safety thermostat 10 Cap ...

Страница 6: ...INTRODUCTION Translation of the original instructions 6 FIG C MOD F T F2 8 94G A Piezoelectric FIG D 1 Bracket 2 Pilot light nozzle 3 Extends drainage 4 Ignition spark plug FIG E Burner air adjustment ...

Страница 7: ...94G F2 18 98G F25 94G F2 25 98G 1 Ignition spark plug 2 Burner ignition control unit 3 Switch 4 Power supply terminal board WIRING DIAGRAM F18 94G F2 18 98G F25 94G F2 25 98G 1 Thermostat 2 Green indicator light 4 Power supply terminal board 3 White indicator light 5 Switch 6 Solenoid ...

Страница 8: ...INTRODUCTION Translation of the original instructions 8 1 3 Example installation of the appliance ...

Страница 9: ... electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event ...

Страница 10: ...ential effects on the environment and human health may be due to the misuse of the same equipment or parts of it The symbol next to the rating plate indicates the obligation of separate collection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 2012 19 EU 2 3 ...

Страница 11: ... not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The ...

Страница 12: ...t least 3 mm The connection terminal is located behind the rear wall Proceed as follows to install the power supply cable Remove the rear panel Pass the new connection cable through the cable gland connect the leads to the corresponding terminal on the terminal block and fasten them securely Lock the cable with the cable gland and refit the panel The earth ground lead must be longer than the other...

Страница 13: ...eplace the screw firmly tighten and check the seal Liquid gas connection G30 G31 The liquid gas connection pressure is 30 mbar for butane and 37 mbar for propane Check the data plate measure the pressure and verify that the description of the nozzle installed matches the information provided by the manufacturer Methane gas connection H G20 The methane gas connection pressure is 20 mbar Check the d...

Страница 14: ...andard Resetting the gas supply to the appliance must be possible only by hand 1 Extractor hood 2 Servo system B11 type devices See data plate Natural evacuation fig 3 Connection to an efficient natural draft fume stack by means of a windproof connection with discharge of combustion products directly to the outside Forced evacuation fig 4 The gas supply to the appliance must be directly servo cont...

Страница 15: ...f the original instructions 15 1 Windproof fume stack fig 3 Extractor hood fig 4 2 Servo system B11 type appliances are supplied on request with a hood or a hood and windproof fume stack to be assembled and delivered separately ...

Страница 16: ...mm 25 25 25 F2 25 98G Burner injector 1 100 mm 8 x 115 8 x 115 8 x 170 Pilot injector 1 100 mm 30 30 51 Consumption kg h 3 155 kg h 3 108 m3 st h 4 233 Primary air H mm 25 25 25 F13T 94G Burner injector 1 100 mm 3 x 100 3 x 100 3 x 180 Pilot injector 1 100 mm 1 x 30 1 x 30 1 x 51 Consumption kg h 0 946 kg h 0 932 m3 st h 1 269 Primary air H mm max max max F2 13T 98G Burner injector 1 100 mm 6 x 10...

Страница 17: ...BURNS Do not touch hot surfaces floor with your hands or other parts of the body to avoid burns caused by high temperatures After switching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation Fill the tank with oil up to the lower reference mark 5 2 Switching the pilot burner on Press and turn the valve knob Fig B Pos 8 into positio...

Страница 18: ...ervention is signalled by the main burner and the pilot burner both switching off If this happens operations can be reset by fully pressing the red button on the safety thermostat If the problem occurs again call the assistance service so that the causes can be eliminated Warning If using the fryer with products other than oil lard for example that have considerable thermal inertia it is necessary...

Страница 19: ...quired to have a suitable recipient for emptying the water oil Insert the drain tube as shown on the drawing position the container Push the safety device upwards against the involuntary openings A and move the lever B Warning Pay close attention to the distance between the appliance and the edges of the support ...

Страница 20: ...ated on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasing the frequency depending on the degree of use The status of connections especially on the terminal board and the power supply cable as well as the status of the gas connections The operating condition ...

Страница 21: ...tment thermostat after having removed the dashboard and or front panel unscrew the screw couplings of the gas pipes and disconnect the valve s electrical connections For Top units fitted with a Eurosit valve unscrew the screw fittings of the gas pipes and remove the valve bulb Then replace the damaged parts and install the new ones THERMOCOUPLE fig D pos 3 unscrew the pilot burner coupling unscrew...

Страница 22: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...

Отзывы: