Lotus CP-558ET Скачать руководство пользователя страница 17

MAINTENANCE

Translation of the original instructions

17

5.2

Spare parts

It is possible to replace parts such as the valve, the piezoelectric or the ignition control unit (depending on
the type of appliance) or the gas pipes easily and quickly.
To replace such parts, proceed as follows:
 

·

SWITCH: Remove the knob and open the panel, unscrew the two screws that fasten the switch/regulator

to the panel, remove all the electrical connections and proceed with replacement

 

·

LEVEL CONTROL UNIT: disconnect the electrical connections that connect it to the sensor, unscrew the

screws that fasten it to the bottom of the appliance and replace it

 

·

ROTARY HEATING ELEMENT; remove the panel and remove the wires connecting the heating element.

Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket
until it can be removed. At this point, the heating element can be removed from inside the bowl, pushing
it towards the draught diverter. Also replace the 3 o-rings (see point 1 in figure C) and apply a bit of
grease to facilitate the operation.

 
 

Note

 

It  is  recommended  to  replace  the  three  o-rings  once  a  year  as  they  are  subject  to  wear  and,  with
time, can cause leaks

 

Caution

 

WHAT TO DO IN THE EVENT OF FAULTS:

Close the gas connection cock and/or switch off the power using the up-line device. Notify
customer service.

 

Warning

 

MEASURES TO BE TAKEN IF THE APPLIANCE IS NOT TO BE USED FOR A LONG TIME:

Close the gas cock and/or disconnect the power supply. Clean the system as specified above.

Содержание CP-558ET

Страница 1: ...and operating instructions ELECTRIC PASTA COOKER FOR PROFESSIONAL USE CP 558ET CPA 558ET Model LIBR ISTR CP110E Code 5630517A0 Review 1 Edition date 10 06 2022 Language English LOTUS S p A Via Calmaor...

Страница 2: ...table 9 3 INSTALLATION 10 3 1 Delivery checks 10 3 2 Removing the packaging 10 3 3 Mechanical installation 10 3 4 Electrical gas connections 10 3 5 Water connection and drainage 11 4 INSTRUCTIONS FOR...

Страница 3: ...TRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 CP 558ET CPA 558ET A Data Plate B Electrical connection D Water connection R 3 4 M E Water drain R 1...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 1 2 Components FIG B CP Water filling tap FIG C ROTARY RESISTANCE 1 O rings 2 Rotary heating element...

Страница 5: ...nslation of the original instructions 5 WIRING DIAGRAM CP 558ET 1 Switch 2 Power supply terminal board 3 Switching terminal board 4 Heating element 5 White indicator light 6 Green indicator light 7 Sa...

Страница 6: ...PA 558ET 1 Water level control unit 2 Switch 3 Bipolar diverter 4 Water solenoid 5 Bipolar switch 6 Power supply terminal board 7 Switching terminal board 8 Heating element 9 Level probe 10 White indi...

Страница 7: ...INTRODUCTION Translation of the original instructions 7 1 3 Example installation of the appliance...

Страница 8: ...electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be hel...

Страница 9: ...of the use of certain hazardous substances in electrical and electronic equipment the potential effects on the environment and human health may be due to the misuse of the same equipment or parts of i...

Страница 10: ...not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulat...

Страница 11: ...device can be fully disconnected from the mains this device must have a contact aperture of at least 3 mm The connection terminal is located behind the rear wall Proceed as follows to install the pow...

Страница 12: ...d bottlenecks or siphon effects Water is drained by gravity Inasmuch it is essential that the drain is below the exit point of the pipe Commissioning before using the appliance clean it carefully espe...

Страница 13: ...ore carrying out any cleaning or maintenance operation Do not operate the appliance without water in the tank 4 2 Turning on the appliance When the appliance is powered up the red indicator light flas...

Страница 14: ...ove the threaded nut on the front panel of the appliance and use a screwdriver to press the red button on the thermostat for a few seconds If the problem occurs again even if the tank is full of water...

Страница 15: ...ocks the operation of the device and an alarm is signalled by the red indicator light ON steady To reset the alarm condition first eliminate the fault that caused it to trip broken or disconnected lev...

Страница 16: ...e and its safety systems Warning For maintenance replacement of components order and use only original spare parts Replacing parts must exclusively be performed by authorised and or qualified personne...

Страница 17: ...remove the panel and remove the wires connecting the heating element Unscrew the two 8 mm screws that fasten the bracket to the heating element and pull out the bracket until it can be removed At this...

Страница 18: ...are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For m...

Отзывы: