BURNERS TECHNICAL DATA TABLE (ITGB)
Translation of the original instructions
22
4 BURNERS TECHNICAL DATA TABLE (ITGB)
4.1
Burners technical data table
Technical data table - Burners PCCF S70GAE
12.68 kWh/KG
G30
BUTANE
30 mbar
12.87 kWh/KG
G31
PROPANE
37 mbar
9.45 kWh/m3st.
G20
METHANE H
20 mbar
Burner max 3.5 kW-min 1.15 kW
Burner injector 1/100 mm
90
90
145
Minimum adjustment 1/100 mm
50
50
adjustable
Pilot injector 1/100 mm
20
20
35
Consumption
kg/h 0.276
kg/h 0.272
m3 st./h 0.370
Primary air h = mm
open
open
open
Burner max 5.5 kW-min 1.55 kW
Burner injector 1/100 mm
115
115
175
Minimum adjustment 1/100 mm
60
60
adjustable
Pilot injector 1/100 mm
20
20
35
Consumption
kg/h 0.434
kg/h 0.427
m3 st./h 0.582
Primary air h = mm
open
open
20
Burner max 7.5 kW-min 2.5 kW
Burner injector 1/100 mm
135
135
205
Minimum adjustment 1/100 mm
75
75
adjustable
Pilot injector 1/100 mm
20
20
35
Consumption
kg/h 0.591
kg/h 0.582
m3 st./h 0.794
Primary air h = mm
20
20
20
Oven burner max 7.3 kW-min 2.2 kW
Burner injector 1/100 mm
145
145
205
Minimum adjustment 1/100 mm
75
75
adjustable
Pilot injector 1/100 mm
1x19
1x19
1x27
Consumption
kg/h 0.576
kg/h 0.567
m3 st./h 0.772
Primary air h = mm
12
12
12
Oven burner max 11 kW-min 3.5 kW
Burner injector 1/100 mm
175
175
270
Minimum adjustment 1/100 mm
100
100
adjustable
Pilot injector 1/100 mm
1x19
1x19
1x27
Consumption
kg/h 0.867
kg/h 0.855
m3 st./h 1.164
Primary air h = mm
13
13
13