INSTALLATION

Translation of the original instructions

11

 

Installation  operations,  any  conversion  to  other  types  of  gas  and  start-up  must  only  be
performed by qualified personnel, in accordance with current regulations.

 

Gas systems, electrical connections and premises where the appliances are installed must comply with
current regulations in the country of installation; in particular, the appliance must be installed in a room with
good ventilation, if possible under a suction hood to ensure complete evacuation of the exhaust gases
formed during combustion. The air required for combustion is 2 m3/h per kW of installed power. The
appliance can be installed alone or in series with other appliances in our production range. A minimum
distance of 10 cm between appliances must be respected to prevent contact with any walls made of
flammable material; furthermore, appropriate measures should also be adopted to ensure the thermal
insulation of flammable parts, such as the installation of heat shields; take special care to ensure that
appliances are installed in an appropriate and safe manner. The support feet can be adjustable in height and
any unevenness can therefore be eliminated.
 

GAS CONNECTION

The gas connection (see installation drawing) must be implemented using steel or copper pipes or steel
hoses, in compliance with applicable national standards. All appliances must be equipped with a gas shut-off
valve and fast-closing valve. Once installation is complete, make sure that there are no gas leaks from the
fittings; to do this, do not use a naked flame but substances that do not cause corrosion, such as solutions of
soapy water or leak detectors. All our appliances are subjected to detailed examination: the type of gas,
pressure in use and the pertinent category are indicated on the data plate (see attachment).
 

Note

 

The year of construction of the appliance is indicated under "N" on the data plate. The first 2 digits
indicate the year of construction.

 

·

THERMAL OUTPUT CONTROL

 
The appliances must be checked in order to verify that their thermal output is correct:
 

·

Thermal output is indicated on the appliance's data plate;

·

Firstly, make sure that appliance is set for the type of gas used and then make sure that the indication on

the data plate matches this gas. To adapt the appliance to another type of gas, make sure that the type of
gas in question complies with the information in this instruction manual.

 

Warning

 

Pressure is measured with a pressure gauge (minimum resolution of 0.1 mbar) mounted on
the appropriate socket. Remove the M6 locking screw and insert the pressure gauge tube.
The test must be performed with all the burners on the appliance switched on and all the
appliances in the same line switched on. After taking the measurement, replace the screw,
firmly tighten and check the seal.

 

Liquid gas connection G30 / G31
 
The liquid gas connection pressure is 30 mbar for butane and 37 mbar for propane. Check the data plate,
measure the pressure and verify that the description of the nozzle installed matches the information provided
by the manufacturer.
 
Methane gas connection H G20
 
The methane gas connection pressure is 20 mbar. Check the data plate, measure the pressure and verify
that the description of the nozzle installed matches the information provided by the manufacturer.
 

·

CHECKING THE PRIMARY AIR FOR MAIN BURNERS AND PILOT NOZZLE

Содержание 5630518A0

Страница 1: ...nstallation and operating instructions GAS GRILL FOR PROFESSIONAL USE CW 114G Model LIBR ISTR CW110G Code 5630518A0 Review 1 Edition date 14 06 2022 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Страница 2: ... 10 4 BURNERS TECHNICAL DATA TABLE ITGB 14 4 1 Burners technical data table 14 6 INSTRUCTIONS FOR USE 15 6 1 General information 15 6 2 Switching the pilot burner on 15 6 3 Starting the main burner and adjusting the temperature 15 6 4 Switching the main burner off 15 6 5 Switching the appliance off 15 6 6 Emptying the container 16 6 7 Observations and advice 16 7 MAINTENANCE 17 7 1 Routine 17 7 2 ...

Страница 3: ...INTRODUCTION Translation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 CW 114G A Data Plate C Gas connection ...

Страница 4: ...Translation of the original instructions 4 1 2 Components FIG A 1 Injector 2 Extends drainage 3 Pilot 4 Ignition spark plug 5 6 Tap knob 7 Gas pipes 8 Gas tap 9 Piezoelectric 10 Fat collection pan 11 Burner 12 Tank ...

Страница 5: ...INTRODUCTION Translation of the original instructions 5 FIG B A Piezoelectric FIG C 1 Bracket 2 Pilot light nozzle 3 Extends drainage 4 Ignition spark plug FIG D Burner air adjustment ...

Страница 6: ...INTRODUCTION Translation of the original instructions 6 FIG E 1 By pass ...

Страница 7: ...INTRODUCTION Translation of the original instructions 7 1 3 Example installation of the appliance ...

Страница 8: ... electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event ...

Страница 9: ...ORMATION Translation of the original instructions 9 2 2 Technical data table Technical data table CW S110G MODEL DIMENSIONS GAS FITTING ISO 7 1 RATED TOTAL GAS FLOW kW LAVA STONE Kg CW 114G 40x110x90h R 1 2GM 9 9 ...

Страница 10: ... install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The appl...

Страница 11: ...hat do not cause corrosion such as solutions of soapy water or leak detectors All our appliances are subjected to detailed examination the type of gas pressure in use and the pertinent category are indicated on the data plate see attachment Note The year of construction of the appliance is indicated under N on the data plate The first 2 digits indicate the year of construction THERMAL OUTPUT CONTR...

Страница 12: ...ined in a bag included in the supply and are marked in hundredths of mm see Burners technical data table INSTRUCTIONS FOR EVACUATING EXHAUST GASES A type devices see data plate A type appliances must discharge combustion products into appropriate hoods or similar devices connected to an efficient fume stack or directly to the outside Natural evacuation Fig 1 If this is not possible using an air su...

Страница 13: ...liance must be possible only by hand If the installation is under a hood the terminal part of the appliance s exhaust pipe must be at least 1 8 meters from the appliance s support surface ground The outlet section of the exhaust pipes for combustion products must be placed within the perimeter in relation to the hood itself 1 Windproof fume stack fig 3 Extractor hood fig 4 2 Servo system B11 type ...

Страница 14: ...ata table Burner CW S110G 12 68 kWh KG G30 BUTANE 30 mbar 12 87 kWh KG G31 PROPANE 37 mbar 9 45 kWh m3st G20 METHANE H 20 mbar CW 114G Burner max 9 kW min 2 7kW Burner injector 1 100 mm 1 x 150 1 x 150 1 x 220 Minimum adjustment 1 100 mm 70 70 adjustable Pilot injector 30 30 51 Primary air setting h mm 17 17 17 Consumption kg h 0 710 kg h 0 699 m st h 0 952 ...

Страница 15: ...ouch hot surfaces floor with your hands or other parts of the body to avoid burns caused by high temperatures After switching off the appliance wait for a sufficient time for it to cool before carrying out any cleaning or maintenance operation 6 2 Switching the pilot burner on Place gas knob in position and hold it pressed Simultaneously press the piezoelectric button to generate the spark the pil...

Страница 16: ...urner and the pilot burner 6 6 Emptying the container This rack should be checked regularly and emptied before it is full In any case the rack must be cleaned after switching off the appliance 6 7 Observations and advice In the case of appliances with two cooking zones it is possible to set different temperatures on the two halves of the plate or use only one half ...

Страница 17: ...ated on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasing the frequency depending on the degree of use The status of connections especially on the terminal board and the power supply cable as well as the status of the gas connections The operating condition ...

Страница 18: ...e is used For this reason and to facilitate maintenance the burner can be conveniently removed and cleaned as required Additionally meat enzymes salt etc are highly aggressive for burner parts in steel The burner cannot be made of stainless steel since heat deformation of this material would compromise burner operation Some parts of the burner are in AISI 304 others in AISI 316 and others still in...

Страница 19: ...T OF FAULTS Close the gas connection cock and or switch off the power using the up line device Notify customer service Warning MEASURES TO BE TAKEN IF THE APPLIANCE IS NOT TO BE USED FOR A LONG TIME Close the gas cock and or disconnect the power supply Clean the system as specified above ...

Страница 20: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...

Отзывы: