background image

INSTALLATION

Translation of the original instructions

16

Warning

 

Installation  operations,  any  conversion  to  other  types  of  gas  and  start-up  must  only  be
performed by qualified personnel, in accordance with current regulations.

 

Gas systems, electrical connections and premises where the appliances are installed must comply with
current regulations in the country of installation; in particular, the appliance must be installed in a room with
good ventilation, if possible under a suction hood to ensure complete evacuation of the exhaust gases
formed during combustion. The air required for combustion is 2 m3/h per kW of installed power. The
appliance can be installed alone or in series with other appliances in our production range. A minimum
distance of 10 cm between appliances must be respected to prevent contact with any walls made of
flammable material; furthermore, appropriate measures should also be adopted to ensure the thermal
insulation of flammable parts, such as the installation of heat shields; take special care to ensure that
appliances are installed in an appropriate and safe manner. The support feet can be adjustable in height and
any unevenness can therefore be eliminated.
 

ELECTRICAL CONNECTION

Caution

 

In accordance with international provisions, when connecting the appliance an automatic
device must be installed up-line of it so that the device can be fully disconnected from the
mains; this device must have a contact aperture of at least 3 mm.

The connection terminal is located behind the rear wall. Proceed as follows to install the power supply cable:
 

·

Remove the rear panel.

·

Pass the new connection cable through the cable gland, connect the leads to the corresponding terminal

on the terminal block and fasten them securely.

·

Lock the cable with the cable gland and refit the panel. The earth/ground lead must be longer than the

others so that if the cable gland breaks it is disconnected after the power cables.

 

Note

 

Make sure that the mains voltage complies with the data on the appliance's ID plate and that there is
good conductivity to earth/ground. Pay attention when inserting leads to ensure they do not obstruct
the normal course of work and routine appliance cleaning operations. Also make sure that the power
cable is never pulled taut and is not placed in contact with sources of heat.

Note

 

The connection cable must have the following characteristics: it must be silicone type (to
withstand temperatures of 180 °C), and must have an appropriate cross-section for the power
of the appliance (see technical data table).

 

EQUIPOTENTIAL

 
The appliance must be connected to an equipotential system. The connecting screw is located on the rear of
the appliance and is marked by the yellow symbol above it.
 

Warning

 

The manufacturer is not liable for and does not indemnify damages caused by incorrect
inadequate installations that do not comply with these instructions.

GAS CONNECTION

The gas connection (see installation drawing) must be implemented using steel or copper pipes or steel
hoses, in compliance with applicable national standards. All appliances must be equipped with a gas shut-off

Содержание 08270450

Страница 1: ...tions GAS PASTA COOKER FOR PROFESSIONAL USE CP 74G CP 76G CP 78G CPA 74G CPA 76G CPA 78G CPT 74G CPT 76G Model LIBR ISTR CP70G CON SIC Code 563006602 Review 1 Edition date 19 11 2018 Language English LOTUS S p A Via Calmaor 46 31020 San Vendemiano 39 0438 778020 39 0438 778277 ...

Страница 2: ... 3 5 Water connection and drainage 19 4 BURNERS TECHNICAL DATA TABLE ITGB 20 4 1 Burners technical data table 20 5 INSTRUCTIONS FOR USE 21 5 1 General information 21 5 2 Switching the pilot burner on 21 5 3 Starting the main burner and adjusting the temperature 22 5 4 Switching the main burner off 22 5 5 Switching the appliance off 22 5 6 Emptying the tank 22 5 7 Top appliances bowl emptying 23 5 ...

Страница 3: ...anslation of the original instructions 3 1 INTRODUCTION 1 1 Installation drawing FIG 1 CP 74G CP 78G CPA 74G CPA 78G A Data Plate B Electrical connection C Gas connection D Water connection R 3 4 M E Water drain R 1 M ...

Страница 4: ...INTRODUCTION Translation of the original instructions 4 FIG 2 CP 76G CPA 76G A Data Plate B Electrical connection C Gas connection D Water connection R 3 4 M E Water drain R 1 M ...

Страница 5: ...INTRODUCTION Translation of the original instructions 5 CPT A Data Plate C Gas connection ...

Страница 6: ...INTRODUCTION Translation of the original instructions 6 1 2 Components FIG A 1 Tap knob 2 Red indicator light 3 Power button 4 On off switch 5 Hole for indicator light 6 Water discharge ...

Страница 7: ...INTRODUCTION Translation of the original instructions 7 FIG C 1 By pass FIG B CP Water filling tap FIG D 1 Bracket 2 Pilot light nozzle 3 Ignition spark plug 4 Extends drainage 5 Injector ...

Страница 8: ...nal instructions 8 WIRING DIAGRAM CP 74G CP 76G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Gas solenoid 5 Power button 6 Bipolar switch 7 Power supply terminal board 8 Level probe 9 Red warning light ...

Страница 9: ...AGRAM CPA 74G CPA 76G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Bipolar diverter 5 Water solenoid 6 Gas solenoid 7 Bipolar switch 8 Illuminated bipolar switch 9 Power supply terminal board 10 Level probe 11 Red indicator light ...

Страница 10: ...iginal instructions 10 WIRING DIAGRAM CP 78G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Gas solenoid 5 Power button 7 Power supply terminal board 6 Bipolar switch 8 Level probe 9 Red warning light ...

Страница 11: ...NG DIAGRAM CPA 78G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Bipolar diverter 5 Water solenoid 6 Gas solenoid 7 Bipolar switch 8 Illuminated bipolar switch 9 Power supply terminal board 10 Level probe 11 Red indicator light ...

Страница 12: ...INTRODUCTION Translation of the original instructions 12 1 3 Example installation of the appliance ...

Страница 13: ...e electrical safety of this equipment is only ensured when it is correctly connected to an effective ground earth system as required by current electrical safety standards The manufacturer cannot be held liable for any damage caused if the system is not connected to ground earth Before carrying out any cleaning or maintenance tasks on the equipment unplug it from the electricity mains In the event...

Страница 14: ...collection The penalties provided for in the event of improper disposal of RAEE Waste Electrical and Electronic Equipment are those provided for by the national transpositions of European Directives 2012 19 EU 2 3 Technical data table Electrical technical data table CP S70G MODEL POWER SUPPLY MAXIMUM ABSORPTION A MAXIMUM ELECTRIC POWER kW POWER SUPPLY CABLE silicon type CP 74G 230V 50 60 Hz 0 1 0 ...

Страница 15: ... not install the appliance near equipment machines used in cold processes If the appliance has to be installed close to cold process equipment it is advisable to install non combustible thermal insulating material and or neutral elements between them 3 4 Electrical gas connections Before being offered for sale on the market the appliance was subjected to gas and electrical testing as required The ...

Страница 16: ...t least 3 mm The connection terminal is located behind the rear wall Proceed as follows to install the power supply cable Remove the rear panel Pass the new connection cable through the cable gland connect the leads to the corresponding terminal on the terminal block and fasten them securely Lock the cable with the cable gland and refit the panel The earth ground lead must be longer than the other...

Страница 17: ...eplace the screw firmly tighten and check the seal Liquid gas connection G30 G31 The liquid gas connection pressure is 30 mbar for butane and 37 mbar for propane Check the data plate measure the pressure and verify that the description of the nozzle installed matches the information provided by the manufacturer Methane gas connection H G20 The methane gas connection pressure is 20 mbar Check the d...

Страница 18: ...andard Resetting the gas supply to the appliance must be possible only by hand 1 Extractor hood 2 Servo system B11 type devices See data plate Natural evacuation fig 3 Connection to an efficient natural draft fume stack by means of a windproof connection with discharge of combustion products directly to the outside Forced evacuation fig 4 The gas supply to the appliance must be directly servo cont...

Страница 19: ... to a suitable drain in compliance with applicable legislation It is advisable to connect pipes without bends to avoid bottlenecks or siphon effects Water is drained by gravity Inasmuch it is essential that the drain is below the exit point of the pipe Commissioning before using the appliance clean it carefully especially the tank see the cleaning and care section Check the appliance s water conne...

Страница 20: ...235 Minimum adjustment 1 100 mm 100 100 adjustable Pilot injector 25 25 41 Consumption kg h 1 498 kg h 1 476 m st h 2 010 CP 76G Burner 13 95 kW min 7 kW Burner injector 1 100 mm 2 x 130 2 x 130 2 x 205 Minimum adjustment 1 100 mm 130 130 adjustable Pilot injector 25 25 41 Consumption kg h 1 100 kg h 1 084 m st h 1 476 CPT 74G Burner 6 kW min 2 75 kW Burner injector 1 100 mm 1 x 125 1 x 125 1 x 18...

Страница 21: ...re carrying out any cleaning or maintenance operation Do not operate the appliance without water in the tank 5 2 Switching the pilot burner on The corresponding burner marked on the index is indicated above each knob on the front panel When the appliance is powered up the red indicator light flashes briefly for about 1 2 second If there is no water in the tank the red indicator light continues fla...

Страница 22: ...nto position The burner turns OFF and only the pilot flame remains ON 5 5 Switching the appliance off Press and turn the gas cock knob to position 0 This control blocks the gas supply to both the main burner and the pilot burner 5 6 Emptying the tank To perform this operation open the drain tap lever in vertical position which can only be reached from the door of the cabinet underneath the applian...

Страница 23: ...the lever B Warning Pay close attention to the distance between the appliance and the edges of the support 5 8 Pasta cooker with automatic loading If the probe does not detect water in the tank the system resets the correct level and after 15 sec disables the heating element an alarm is signalled by the red indicator light flashing When the probe detects water again the heating element is immediat...

Страница 24: ...ates an internal timer for the duration of this stage If the filling lasts continuously for more than 350 seconds the system blocks the operation of the device and an alarm is signalled by the red indicator light ON steady To reset the alarm condition first eliminate the fault that caused it to trip broken or disconnected level probes water system problems drain tap open and then switch the system...

Страница 25: ...ndicated on the component itself The appliance does not require any special maintenance but during the use of the equipment it is advisable to check the following at least once a year possibly increasing the frequency depending on the degree of use The status of connections especially on the terminal board and the power supply cable as well as the status of the gas connections The operating condit...

Страница 26: ...ace such parts proceed as follows GAS TAP after disassembling the front panel unscrew the gas connection screw couplings remove the coupling replace the faulty parts and install the new ones in sequence THERMOCOUPLE unscrew the pilot burner coupling unscrew the gas tap coupling in the same way and replace the element SPARK PLUG unscrew the coupling remove the damaged one and replace it SOLENDOID U...

Страница 27: ...s are available commercially but a diluted solution of acetic acid can also be used To clean STAINLESS STEEL appliances it is advisable to use detergents specifically formulated for this material For minor cleaning a mild washing up liquid solution may also be used Do not wash the appliance with jets of water under pressure Avoid using detergents containing abrasive powders or bleaches of any kind...

Отзывы: