Page
17
/
25
Operating Instructions
LTS 140 / 138 / 150
slide
All rights reserved, all indications without engagement, subject to modifications.
LOTUS TRANSFERS PRESS SOLUTIONS GMBH & CO. KG
Errors and possible causes
ERROR MESSAGE
POSSIBLE CAUSE
TROUBLESHOOTING
The main switch is not lit
- Lamp defective
- Power cable defective
Replace the part
The heating plate does not
go down
- Control board defective
- Electric valve defective
- Start-Knop defective
- Hands safety system defect
Replace the part
The heating plate moves
down independently
No pneumatic connection available
(machine does not get air supply)
Checking the air system
The display shows "000"
and there is an acoustic
signal
- Control board defective
- The temperature is 20°C above
the set temperature
Replace the part
The display shows "111"
Temperature sensor defective
Replace the part
The display does not
count the seconds, the
heating plate does not
stay down
Pressure regulator defective
Clean or replace the
pressure regulator
The heating plate does not
heat up
- Wiring heating plate defective
- Heating rod/heating rods defective
Replace the part
Air escapes from the pres-
sure filter
(on the back of the press)
- Electric valve defective
- Pressure cylinder defective
Replace the part
The printing cylinder
moves slowly downwards
The pressure regulator is clogged
Clean the pressure reg-
ulator or replace the
part
Display is not lit
- Control board defective
- Power cord defective
- Fuse defective
Replace the part