S35
Pre-Installation and Site Preparation Guide
Page 10 of 52
Loring Smart Roast Proprietary – This document is controlled by
Document Control. By printing this document, it will become a “Reference” copy.
Users are responsible for verifying that it is the latest revision available.
1006705 Rev B
S35 Specifications
S35 Specification
Value
System Weight (R Cart)
1
2210 lbs (1000 kg) uncrated
System Weight (Destoner)
1
424 lbs (192 kg) uncrated
Maximum Batch Size
77 lbs (35 kg)
Minimum Batch Size
15.4 lbs (7 kg)
Nominal Electrical Power
3.7 kW
Peak Electrical Power
6.6 kW
Maximum BTU Rating
300,000 BTU/h (76 K kcal/h)
Hot Stack Max Continuous Temperature
2
1400 °F (760 °C)
Hot Stack Max Intermittent Temperature
2
1450 °F (788 °C)
Hot Stack Max Flow
3
52 dscfm (88 dsm
3
/hr)
Hot Stack Max Flow (Peak Air Cool)
5
450 dscfm (765 dsm
3
/hr)
Hot Stack Minimum Duct Diameter
4
8 in (203 mm)
Cooling Exhaust Max Flow
5
1560 scfm (2650 sm
3
/hr)
Cooling Duct Diameter
4
8 in (203 mm)
Table 1.
S35 Basic Equipment Specifications
Notes:
1 Exact system weight may depend on options selected.
2 Consult local and regional regulations for air quality, temperature, and emissions restrictions.
3 Dry, or water content of the flue removed, under standard pressure and temperature conditions,
i.e. 29.9 in HG (760 mm HG) and 68°F (20°C).
4 Larger stack diameters or stack openings may be required under some conditions.
5 Add the Hot Stack Max Flow (Peak Air Cool) and Cooling Exhaust Max Flow to obtain the total
air flow out of the building. This may be needed in the event that additional air intake, otherwise
known as makeup air, is needed at the installation site.