Using the Main Menu
16
3. Check
Enable
to enable video loss events for the selected channel.
4. Configure the following to customize settings for video loss events:
•
Period
: Click
Setup
to configure a schedule for video loss events. It is recom-
mended to leave this on the default setting, so you can be alerted at any time one
of your cameras loses video.
•
Alarm Out
: Select the alarm output devices (not included) that will trigger when
video loss occurs.
•
Latch
: Enter the number of seconds an alarm output device will activate after vid-
eo loss occurs.
•
Show Message
: Check to show a popup message on the monitor if one of your
cameras loses video.
•
Send Email
: Check to enable email alerts. You must configure email alerts before
you will be able to receive them (see 16.3.5
Configuring Email Alerts
, page 58).
•
Channels
: Click the checkbox to enable video recording when video loss occurs.
You can then select the channels the system will record when video loss occurs
on the currently selected channel.
•
PTZ Activation
: Check to enable PTZ actions when video loss occurs (PTZ cam-
era required; not included). Click
Setup
to select which PTZ actions will be taken
by each camera.
•
Post_REC
: Enter the number of seconds the system will record after video loss
occurs.
•
Sequence
: Check to enable a custom sequence mode when motion is detected
on the selected channel. Then click the channels you would like to display in the
custom sequence mode.
•
Snapshot
: Click the box to enable snapshot recording when video loss occurs.
You can then select which channels will save snapshots when video loss occurs
on the currently selected channel.
•
Buzzer
: Check to enable the system buzzer when video loss occurs on the cur-
rently selected channel.
5. Click
OK
to save changes.
16.3.10
Configuring Alarm Input Devices
You can connect alarm input devices such as motion sensors (not included) or glass
break detectors (not included) to the system. The system can be set to trigger recording
or take other actions when these devices are activated.
To configure alarm input devices (not included):
1. From the Main Menu, click
and then click
Event>Local Alarm
.
2. Configure the following to activate an alarm input device:
•
Alarm In
: Select the alarm input port the device is connected to.
•
Enable
: Check to enable the alarm input device connected to the selected port.
•
Type
: Select
NO (Normal Open)
or
NC (Normal Close)
depending on the type
of alarm input device you have.
#LX400021; r. 4.0/30344/30494; en-US
62
Содержание NR800 Series
Страница 1: ...Instruction Manual NR800 Series...
Страница 2: ......
Страница 3: ...Instruction Manual NR800 Series LX400021 r 4 0 30344 30494 en US iii...
Страница 10: ......
Страница 61: ...Using the Main Menu 16 3 Click OK to save changes LX400021 r 4 0 30344 30494 en US 51...
Страница 115: ...Using FLIR Cloud Client for PC or Mac 18 LX400021 r 4 0 30344 30494 en US 105...
Страница 178: ......
Страница 179: ......