Lorentz PS600 BADU Top 12 Скачать руководство пользователя страница 6

6

3

OPERATING THE PUMP

This explains the function of the switch and
the indicator lights on the pump controller.

SWITCH

POWER ON/OFF

When switched off/on during operation, it resets all
system logic.

Indicator lights

SYSTEM (green)

The controller is switched on and the power source
is present. In low-power conditions, the light may
show even if there is not enough power to run the
pump.

PUMP ON (green)

Motor is turning. Sequence of flashing indicates
pump speed. See below sequence

PUMP OVERLOAD (green changes to red)

SOURCE LOW (red)

The water source dropped below the level of the low-
water probe. After the water level recovers, the pump
will restart, but this light will slowly flash until the sun
goes down, power is interrupted, or the POWER
switch is reset. This indicates that the water source
ran low at least once since the previous off/on cycle.

TANK FULL (red)

Pump is turned off by action of the remote float
switch (or pressure switch or manual switch,
whichever is wired to the “remote float switch”
terminals.

BATTERY LOW (tank light flashes)

Battery systems only

 – battery voltage fell to 44V,

and has not yet recovered to 48V.

RPM indication:

 Pump speed can be read off by

the flashing sequence of the Pump ON LED.

LED ON >  900
One flash

> 1200

Two flash

> 1600

Three flash

> 2000

Four flash

> 2400

Five flash

> 2800

Manual PS600 BADU Top 12

Содержание PS600 BADU Top 12

Страница 1: ...1 www lorentz de info lorentz de release 050509 PS600 BADU Top 12 INSTRUCTION MANUAL INSTALLATION OPERATION SERVICE Solar operated centrifugal surface pump BERNT LORENTZ GmbH Co KG Germany...

Страница 2: ...Installation Terminals 5 2 5 Battery Based System 5 2 6 Wire Sizing 5 3 OPERATING THE PUMP 6 4 AUTOMATIC CONTROLL FOR FULL TANK SHUT OFF 8 5 TROUBLE SHOOTING 9 6 MAINTENACE 10 7 Warranty 10 8 SYSTEM W...

Страница 3: ...re you begin Check the model numbers of all the components of your system and verify that they are the items that you ordered Also check against the PUMP specifications and performance charts end of t...

Страница 4: ...itches remote control etc 92 max efficiency motor controller Adjustable maximum RPM setting PV max open circuit Voc 150 V DC 4 6 pc of 12V nominal solar panels Input voltage battery 48V DC Input curre...

Страница 5: ...and 5 must remain installed No 6 and 7 Connect these two terminals to switch the controller to battery mode The motor will be switched OFF by the controller if the input voltage is below 11 V for a 12...

Страница 6: ...e level of the low water probe After the water level recovers the pump will restart but this light will slowly flash until the sun goes down power is interrupted or the POWER switch is reset This indi...

Страница 7: ...n sunshine on the array is present but too weak for the pump to run it will attempt to start about every 120 seconds During each attempt you will see the PUMP ON light come on When pump runs slowly PU...

Страница 8: ...switch These allow the use of either a normally open N O or a normally closed N C switch Normal refers to the status of the contacts when the switch is DOWN and calling for water Float switch cable re...

Страница 9: ...ring especially in a new installation 2 Make a visual inspection of the condition of the wires and connections Wires are often chewed by animals if they are not enclosed in conduit pipe 3 Pull wires w...

Страница 10: ...y the removal transportation or reinstallation of any defective product Warranty does not cover damage due to failure to install the device properly mishan dling or abuse failure to protect circuitry...

Страница 11: ...Wiring Diagram for Solar direct non battery System PV Modules Solar Panels Before connecting the array to the controller measure the open circuit voltage It must be within a range of PS600 75 135V DC...