SYSTEM

PUMP ON

OVERLOAD

WELL DRY

TANK FULL

BATTERY LOW IF FLASHES

1 2 3 4 5 6 7

low-wate

r

sensor

pr

obe

s

connect

for battery

mode

remote

float switch

NO

Co

m

NC

Max. 50V

Do not connect

this terminal

www.

LORENTZ

.de

T1

T2

T3

T4

T5

T7

V8

Sun. Water. 

Life.

BERNT LORENTZ GmbH & Co. KG 

Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 7548 - 0, Fax - 29, 

www.lorentz.de

 

Errors excepted and possible alterations without prior notice.

Solar direct system Voltage from panels will read 22 – 45 V 
when disconnected (open circuit). Use the left power termi-
nals to connect the solar array with the controller.

The jumper wire on terminal 6 and 7 must be taken out for 
solar direct mode.

Remote Tank Float Switch 

Connect float switch to ter-

minals 4-5 of the pump controller when it breaks contact 
on rise, to turn the pump OFF. Otherwise use terminals 3-4 
for opposite function.

Solar Tracking 

Use stranded wire for flexibility. Secure 

the wires to tracker with plenty of tape. Leave a good slack 
loop to allow free motion of tracker.

4.3 System Wiring for 12 V – 24 V Systems in PV-direct Operation

4.4 Jumper Setting for PS150C Mode

Before start-up check that jumper Jmp2 
is set to PS150C mode, cf. sketch on the 
right.

4.5 High-run Mode

In order to set the battery high-run mode set the jumper 
Jmp1 as shown in above picture. This will increase the Low 
Voltage Disconnect (LVD) settings to 12.3/24.6 V and the 
re-start voltages to 13.3/26.6 V to allow pumping only 
when the batteries receives charging current from the solar 
array. The lifetime of the battery will be increased consi-
derably as cycling is avoided.

4.6 Power Control for PV-direct Operation

PS150 pumps require different current depending on speed 
and lift. When low light conditions are present, the PV 
array cannot supply the required current. If you dont use 
a controller the voltage will drop to nearly zero, and the 
pump will “stall” (like a truck trying to start in 4th gear). 
The pump controller, also called linear current booster (LCB) 
including Maximum Power Point Tracking (MPPT) acts like 
a “gear box” in your car. This device will match the power 
source to the load by transforming the voltage down while 
increasing the current delivered to the motor (like an auto-
matic transmission).

1 PV module 12 V or  
2 PV modules 12 V in series

Jumper Jmp1 
Set to activate High-run Mode

Jumper Jmp2 
Make sure the two left pins are 
connected for PS150C mode

low water sensor

Содержание PS150C

Страница 1: ...g the same Controller PS150 The solar battery is charged up during daylight hours using a separate charger The charger works effectively during re duced sunlight conditions when direct pump operation...

Страница 2: ...pump owner Please give this ma nual to the pump owner or maintenance personnel when the installation is fini shed 2 Warnings The manual contains basic instructions which must be observed during mounti...

Страница 3: ...gevity and enclosed for cleanliness and safety Connect the battery 12V or 24V directly with the and terminal of the controller Do not use the load terminals of the charge controller as they maybe not...

Страница 4: ...s However the backwards pumping flow will be considerably less and the lift ability lower Make sure that the pump turns counter clockwise as indicated on the pump and motor body If you place it in a w...

Страница 5: ...bility Secure the wires to tracker with plenty of tape Leave a good slack loop to allow free motion of tracker 4 2 24V Battery System 24V system Wiring scheme shows serial wiring for a sys tem of 24V...

Страница 6: ...r Setting for PS150C Mode Before start up check that jumper Jmp2 is set to PS150C mode cf sketch on the right 4 5 High run Mode In order to set the battery high run mode set the jumper Jmp1 as shown i...

Страница 7: ...em or 24V 24V system If the pump was recently connected or reconnected 2 to the controller it may be running in reverse direction due to wiring error See section 4 7 If the motor shaft only vibrates a...

Страница 8: ...p pipe vertical from the pump Size mm2 in Type Length m ft Additional pipe length to tank Size mm2 in Type Length m ft Submersible pump cable Wire size mm2 AWG Length controller to pump m ft Max RPM c...