13 TROUBLESHOOTING

PUMP WILL NOT FIT INTO YOUR 5" OR 6" DRILLED
WELL CASING: 

Special elbow fittings are required.

Contact dealer or factory.

PUMP DOESN‘T TURN ON/NO POWER: 

(1) CHECK

FUSE or BREAKER and any control or wiring devices in
line.

PUMP SPINS BUT DOESN‘T PUMP WATER: 

(1) CHECK

DIRECTION of rotation. If not clockwise (viewed from
brass front end) reverse any of the three motor phases.
DO NOT CHANGE THE DC INPUT POLARITY! (2)
CHECK PRIME: Open priming plug or valve (see
instructions). Pour water in. LOSS OF PRIME/INTAKE
PIPE LEAKAGE: CHECK ALL FITTINGS  - a pinhole leak
in suction pipe will cause loss. FOOT VALVE may leak.
Inspect, pressure test, clean or replace. Debris may be
stuck in foot valve causing leak ff not protected by fine
screen or intake filter. REGARDING POLYTHYLENE
PIPE FITTINGS: lf pipe does not stretch tightly over
fittings, it may leak. Gently heat with torch or hot water
and retighten hose clamp WITH WRENCH. Replace
stripped clamps. Use ALL STAINLESS clamps.

NOISY PUMP:
NOISE = CAVITATION = RAPID PUMP WEAR
FIX THE PROBLEM!

STEADY SOUND

 Indicates EXCESSIVE SUCTION due

to any combination of (1) HIGH SUCTION LIFT    mount
pump as low as possible, (2) UNDERSIZED SUCTION
PIPE, (3) CLOGGED FILTER    NOTE: Fiber filter
cartridges may be clogged and LOOK CLEAN (fine silt
is hidden within the fibers). (4) CLOGGED INTERNAL
INTAKE SCREEN. See next two entries. (5) SOFT,
FLEXIBLE HOSE used on intake line may be crushed
or kinked by suction  -replace with more rigid pipe
material.

UNSTEADY BUZZING SOUND

 Indicates LEAK IN

SUCTION LINE allowing AIR to enter. (1) Check for
bubbles in inline (transparent) filter or air in outlet
water. (2) See LOSS OF PRIME in above entry. (3) lf you
have INLINE FILTER with red Pressure Relief Valve (red
button) on top, and it is mounted several feet above
water source, air may be drawing in around the valve,
SEAL AROUND THE VALVE with silicone sealant or
epoxy glue OR unscrew the red button and replace it
with a nut, tightened. (4) lf no source of air leakage is
present, water may have high concentration of DIS-
SOLVED GASSES which release as bubbles in suction
pipe. Reduce suction lift if possible. Install air chamber
in intake line, with valve on top. Pour water in to replace
air when problem reappears. (5) Turn filter to a horizon-
tal position. This allows bubbles to get out of the way of
flow. Do NOT turn it upside down, or dirt may fall in
when filter is changed.

NOISE AND VIBRATION IN PIPES (pressure gauge
vibrates wildly): 

One of four vanes in the pump is

broken. Pump head must be rebuilt    See Rebuild/
Exchange Service. (There should be almost no vibra-
tion of pressure gauge needle.)

FILTER CLOGS FREQUENTLY: (1) INTAKE TOO CLOSE

 to

bottom of well, stream, tank etc. Raise it as high as
feasible to reduce intake of dirt. (2) IMPROVE DEVEL-
OPMENT of spring channel water into a settling tank,
clean tank periodically. (3) Install a larger filter, or plumb
two filters parallel to each other.

CLOGGED INTAKE SCREEN:

 Safety screen is located at

the pump intake. Remove large nut (1300 series) to
inspect and clean screen. (1) IF YOU DON’T HAVE A
CARTRIDGE TYPE FILTER, INSTALL ONE NOW! (2) If
screen is clogged with fibers from filter cartridge, use
higher quality cartridges. (3) If screen is clogged with
rust deposits, replace iron pipe or fittings with plastic,
copper or brass. (4) If mineral or corrosion deposits are
clogging screen, install filter as close as possible to
pump intake. Ask local water professionals what type of
pipe is least susceptible to mineral accumulation and
corrosion in your area.

FILTER IS CLOGGED AND YOU DON’T HAVE REPLACE-
MENT:

 (1) IN LINE FILTER: Purchase common “Rust

and Sediment” fiber wound cartridge at local hardware
store or pump/well supplier. (2) 30" INTAKE FILTER:
Obtain spares from your dealer, factory or industrial
suppliers. In emergency, purchase 3 ordinary 1 10' fiber
filters (not paper) from local source. Glue them end to
end with epoxy and install. (3) TRY BACK WASHING
filter by blasting it with pressure from the inside. For 30"
intake filter, remove check valve and attach garden hose
adapter. Back washing is effective on coarse, sandy
material but is NOT effective with clay, rust, very fine or
sticky deposits.

PURCHASE SPARE FILTERS. NEVER RUN PUMP
WITHOUT A FILTER!

LOW FLOW RATE  † PUMP TURNS FAST, DRAWS LOW
CURRENT:

 Pump is worn out from dirt, rust or other

abrasive particles in water, or from cavitation, from
running dry, or just from age. REPLACE PUMP HEAD.

BOOSTER PUMP TAKES LONG TIME TO REACH CUT
OFF PRESSURE:

 (1) If pump spins fast, see above entry.

(2) If pump rotation slows way down as pressure
builds, wire  is too small. Consult low voltage wire size
chart or ask your dealer for correct wire size.

LOW FLOW RATE  - PUMP TURNS SLOW, DRAWS HIGH
CURRENT

 (may run hot, may blow fuses): Pump is hard

to turn due to: (1) EXCESSIVE VERTICAL LIFT, beyond
system’s capacity: Trade pump head for lower volume
model, or increase size of solar array if it will not
overpower the motor  -see Specifications Chart. (2)
MINERAL DEPOSITS: Turn shaft with two fingers. Will
be hard to turn. Use vinegar, or whatever solution works
to dissolve the mineral deposits in your plumbing.
Remove pipes from pump and allow solution to
circulate through pump by turning it backwards. If this
doesn’t work, or if pump has been damaged, replace or
rebuild.

Содержание PS150 Boost

Страница 1: ...PS150 BOOST INSTRUCTIONS FOR INSTALLATION OPERATION SERVICE Copyright 2004 2005 2006 2007 by BERNT LORENTZ GmbH CoKG all rights reserved...

Страница 2: ...urface pump which cannot be submersed The pump of PS150 BOOST is a positive displace ment vane type pump The PS150 BOOST brushless DC motors are specially made for this system The motor is using very...

Страница 3: ...lation and operation should also be in accordance with local regulations and accepted codes of good practice This INSTRUCTION MANUAL contains maintenance information and is the property of the pump ow...

Страница 4: ...ry Type Quantity of Solar Modules panels Solar Module Type Pump Model Pump Serial Controller Model Controller Serial Installer Record the following Installation Date Installed by Cut in Pressure bar P...

Страница 5: ...ler close to the solar array not the pump This will reduce the risk of lightning damage Protection from heat Electronic devices are most reliable when they are protected from heat Mount the controller...

Страница 6: ...itoring SOURCE LOW Red light Water level is low After recovering the motor will start within 20 minutes Red light will remain ON to indicate low water level has occurred For Reset press the ON OFF swi...

Страница 7: ...y in a trench Therefore make sure inlet lines and fittings are FLUSHED CLEAN before hooking up to pump The INLINE FILTER may have a red push button valve to release pressure for maintenance If filter...

Страница 8: ...secure the pump to the motor BEFORE installing the pump drop a teaspoon of water into the inlet and run the pump HANDLE YOUR PUMP CAREFULLY Never hammer on it clamp it in a vice or drop it To PREVENT...

Страница 9: ...e Reverse the wires if necessary so that pump turns CLOCKWISE looking from purtip end If water flow becomes blocked or if the pump jams or freezes and cannot turn freely the motor will draw excessive...

Страница 10: ...y to battery bank Remote Tank Float Switch Con nect float switch to terminals 4 5 of the pump controller when it breaks contact on rise to turn the pump OFF Otherwise use terminals 3 4 for opposite fu...

Страница 11: ...e Pump ON Pump Speed Well dry Tank full Battery status 9 5 System Wiring for 12 24 V Solar Direct Operation L 1 L 2 L 3 low water sensor probes connect for battery mode remote float switch Battery or...

Страница 12: ...o measure the current used by your pump with an amp meter in series with the line your system metering Current draw will rise in direct proportion to outlet pressure Pressure should NOT be set beyond...

Страница 13: ...oo large to fit peel away some fibers using a knife End caps MUST fit snugly or dirt will enter 1 Connect to Float switch terminal 4 of PS Controller 2 Connect to float switch terminal 5 or 3 dependin...

Страница 14: ...Rebuild Exchange Service There should be almost no vibra tion of pressure gauge needle FILTERCLOGSFREQUENTLY 1 INTAKETOOCLOSEto bottom of well stream tank etc Raise it as high as feasible to reduce in...

Страница 15: ...ut in pressure Turn power off and release water pressure before setting pre charge Modern captive air tank will not need pre charging again GALVANIZED TANK without air bladder MUST BE RECHARGED with a...

Страница 16: ...Copyright 2004 2005 by BERNT LORENTZ KG all rights reserved Bernt Lorentz GmbH Co KG Heidekoppel 16 D 24558 Henstedt Ulzburg Germany Tel 49 4193 7548 0 Fax 49 4193 7548 29 www lorentz de info lorentz...

Отзывы: