PS150 Centric

INSTRUCTIONS FOR
INSTALLATION
OPERATION
SERVICE

Copyright © 2004, 2005 by BERNT LORENTZ KG,  all rights reserved.

Содержание C-SJ5-8

Страница 1: ...PS150 Centric INSTRUCTIONS FOR INSTALLATION OPERATION SERVICE Copyright 2004 2005 by BERNT LORENTZ KG all rights reserved ...

Страница 2: ...The PS150 brushless DC motors are specially made for this system The motor is using very advanced raw earth magnet technology hand made wiring for highest copper density and does not need wearing brushes This results in an exceptional high efficiency with low temperature dissipation PS150 can either be used in a battery system with voltages of 12 24V or alternatively it can be operated as a solar ...

Страница 3: ...dance with local regulations and accepted codes of good practice This INSTRUCTION MANUAL contains maintenance information and is the property of the pump owner Please give this manual to the pump owner or mainte nance personnel when you are finished 3 DIMENSIONS L A B D S packaging shipping volume net weight gross weight mm mm mm mm mm m kg kg C SJ5 8 593 408 185 100 G 1 1 2 650X160X150 0 016 12 1...

Страница 4: ...ery Type Quantity of Solar Modules panels Solar Module Type Pump Model Pump Serial Controller Model Controller Serial Installer Record the following Installation Date Installed by Cut in Pressure bar PSI Cut out Pressure bar PSI Additional Suction Lift m ft Total Pipe Length Pressure Side m ft Total Pipe Length Suction Side m ft Pipe Size Type ...

Страница 5: ...motor or the controller 5 2 Warnings to Installer Location Place the controller close to the solar array not the pump This will reduce the risk of lightning damage Protection from heat Electronic devices are most reliable when they are protected from heat Mount the controller in the shade of the mid day sun An ideal location is directly under the solar array or in a nearby shaded location An alter...

Страница 6: ...Red light Water level is low After recovering the motor will start within 20 minutes Red light will remain ON to indicate low water level has occurred For Reset press the ON OFF switch TANKFULL Red light The motor has been switched OFF by remote switch BATTERYLOW Red light flashing LOW VOLTAGE DISCONNECT when battery is empty in battery mode only to each terminal If dry run protection is not neede...

Страница 7: ...tion then turn the power off If the direction is wrong exchange ANY TWO of the power wires at the controller In any case when you are finished connecting the pump to the controller test it to assure the proper direction Did you install the pump in the well without checking the wiring order or the direction OR Is it running but not pumping HELICAL ROTOR pump model number does NOT contain C Turn the...

Страница 8: ...y to battery bank Remote Tank Float Switch Con nect float switch to terminals 4 5 of the pump controller when it breaks contact on rise to turn the pump OFF Otherwise use terminals 3 4 for opposite function Grounding Connect either battery minus or solar minus to ground never connect both to ground L 1 L 2 L 3 low water sensor probes connect for battery mode remote float switch Battery or Solar Di...

Страница 9: ...Charging NC Com NC SYSTEM PUMP ON OVERLOAD WELL DRY TANK FULL FLASH BATT LOW BATTERY VOLTAGE RPM Controller PS150 combined charge and pump controller 1 or 2 Solar Panels 12 V PS150 Boost 12 24 V Solar direct system Voltage from panels will read 22 44 V when disconnected open circuit Use the left power terminals to connect the solar array with the controller Note The jumper wire on terminal 6 and 7...

Страница 10: ... is present but in a solar direct system there may not be sufficient power to start the pump It should attempt to start at intervals of 120 seconds Pump attempts to start every 120 seconds but doesn t run The controller makes a slight noise as it tries to start the pump The pump will start to turn or just vibrate a little 1 There may be insufficient power reaching the controller A solar direct non...