LORD QUICK START GUIDE
TC-LINK-200
Wireless 12 Channel Analog Input Sensor Node
Wireless Simplicity, Hardwired Reliability™
The TC-Link-200 is a 12-channel wireless sensor used for the precise
measurement of thermocouples. There is no calibration required, users need
only select the desired thermocouple type and the node will output accurate,
low-noise temperature or mV data.
In this document we explain how to deploy the TC-Link-200 for data collection.
This includes electrical wiring, mounting of the device, and using SensorConnect
software to configure the node, start sampling, and display data.
Item
Description
Quantity
A
TC-Link-200
1
B
Antenna with right angle adapter
1
C
AA Lithium batteries (3.6 V dc, 2.4 Ah)
4
D
DIN rail clip
1
#6-32 x 3/8” Thread forming screws
3
Table 1 - TC-Link-200 Configuration Options
Cycle power to the TC-Link-200 using the “on/off” button. A quick push will
power the device on or off. A longer push (approximately two seconds) will
initiate sampling, indicated by the blue light illuminating. A very long push
(approximately 10 seconds) will perform a hardware reset.
Figure 1 - Interface and Indicators
Indicator
Behavior
Node Status
Device status indicator
OFF
Node is OFF
Rapid green flashing on start-up
Node is booting up
1 (slow) green pulse per second
Node is idle and waiting for a command
1 green blink every 2 seconds
Node is sampling
Blue LED during sampling
Node is resynchronizing
Red LED
Built-in test error
Table 2 - Indicator Behaviors