background image

43

G-Link-200-OEM 

USER MANUAL

10.3 Battery Hazards

Lithium batteries contain toxic chemicals that are harmful to humans and the environment. 

Disposal is subject to federal and local laws. Do not discard the battery or the node in the 

trash. Follow proper battery disposal protocol, or contact LORD Sensing Technical Support for 

information on extracting the battery or returning the product for proper recycling and disposal.

10.4 Disposal and Recycling

The G-Link-200-OEM contains internal batteries, printed circuit boards, and electronic 

components. These items are known to contain toxic chemicals and heavy metals that are 

harmful to humans health and the environment. Disposal is subject to federal and local laws. 

Do not discard the device or batteries in the trash. Follow proper electronic and battery waste 

disposal protocol, as dictated by federal and local authorities. Some states have programs for 

extracting reusable parts for recycling.

10.5 Radio Specifications 

The G-Link-200-OEM employs a 2.4GHz IEEE 802.15.4- compliant radio transceiver for 

wireless communication. The radio is a direct- sequence spread spectrum radio and can be 

configured to operate on 16 separate frequencies ranging from 2.405 GHz to 2.480 GHz. 

Following the 802.15.4 standard, these frequencies are aliased as channels 11 through 26. 

For all newly manufactured nodes, the default setting is 2.425 GHz (channel 15).

G-Link-200-OEM

FCC ID: XJQMSLINK0010

IC ID: 8505A-MSLINK0010

This device complies with Part 15 of the United States FCC Rules, and Industry Canada’s 

license-exempt RSSs. Operation is subject to the following two conditions: 1) This device 

may not cause interference, and 2) This device must accept any interference, including 

interference that may cause undesired operation of the device. Changes or modifications, 

including antenna changes not expressly approved by LORD Corporation could void the 

user’s authority to operate the equipment.

Cet appareil est conforme à la Partie 15 des Règles de la FCC des États-Unis et aux RSSS 

exempts de licence d’Industrie Canada. Le fonctionnement est soumis aux deux conditions 

suivantes: 1) Cet appareil ne doit pas causer d’interférences et 2) Cet appareil doit accepter 

toute interférence, y compris les interférences pouvant entraîner un fonctionnement 

indésirable de l’appareil. Les changements ou modifications, y compris les changements 

d’antenne non expressément approuvés par LORD Corporation, pourraient annuler 

l’autorisation de l’utilisateur d’utiliser l’équipement.

Содержание 6305-6002

Страница 1: ...LORD USER MANUAL G Link 200 OEM Wireless Accelerometer Node...

Страница 2: ...oration 3DM 3DM DH 3DM DH3 3DM GX2 Ask Us How DEMOD DC DVRT EmbedSense FAS A G Link Little Sensors Big Ideas LORD Microstrain Live Connect LXRS MathEngine MicroStrain MIP MXRS Node Commander SensorClo...

Страница 3: ...5 Figure 3 Node Operational Modes 6 3 System Operation 7 3 1 Software Installation 7 3 2 Gateway Communication 8 Figure 4 USB Gateway Communication 8 3 3 Connect to Nodes 8 3 3 1 Automatic Node Discov...

Страница 4: ...15 Figure 14 Node Configuration Power Menu 15 5 Wireless Sensor Sampling Configuration 16 5 1 Start Collecting Data 16 Figure 15 Single Node Sampling 16 Figure 16 Network of Nodes Sampling 16 5 2 Net...

Страница 5: ...e 26 MathEngine View 27 Figure 27 FFT Graph in SensorCloud 27 6 2 SensorConnect 28 6 2 1 Using Dashboards and Widgets 28 Figure 28 Viewing Data 28 6 2 2 Navigating Graphs 28 Table 8 Graph View Control...

Страница 6: ...structions 38 Warranty Repairs 38 Non Warranty Repairs 38 9 Specifications 39 9 1 Physical Specifications 39 9 2 Operating Specifications 40 9 3 Mechanical Shock Limits 41 10 Safety Information 42 10...

Страница 7: ...many types of sensors including accelerometers strain gauges pressure transducers load cells torque and vibration sensors magnetometers 4 to 20mA sensors thermocouples RTD sensors soil moisture and hu...

Страница 8: ...ms Amplitude Grms and Gpk pk and Crest Factor allowing long term monitoring of key performance indicators while maximizing battery life To acquire sensor data the G Link 200 OEM is used with a LORD Se...

Страница 9: ...e following configuration options Product Model Part Number G Link 200 OEM integrated chip antenna 8G 40G 6305 6002 6305 6003 G Link 200 OEM MMCX IP67 whip antenna 8G 40G 6305 6181 6305 6141 G Link 20...

Страница 10: ...face Kit Power connector and mating cable factory installation available at time of purchase 6306 1030 Mounting Kit Mounting base and 4 screws 6306 1031 MMCX indoor whip antenna 2 5 dBi antenna with 3...

Страница 11: ...sampling Node is resynchronizing Red LED Built in test error Table 3 Indicator Behaviors 2 4 Node Operational Modes Sensor nodes have three operational modes active sleep and idle When the node is sam...

Страница 12: ...6 G Link 200 OEM USER MANUAL Figure 3 Node Operational Modes...

Страница 13: ...ing SensorConnect is PC based software used for configuring gateways and nodes selecting sampling modes and parameters initializing data acquisition and viewing and saving data 3 1 Software Installati...

Страница 14: ...tomatically with a communication port assignment If the gateway is not automatically discovered verify the port is active on the host computer and then remove and re insert the USB connector Figure 4...

Страница 15: ...Nodes on Other Frequencies tile Figure 6 Node On Other Frequency Highlight the new node being added and select Move Node to Frequency Figure 7 Move Node 3 3 3 Manually Add Node Adding a node manually...

Страница 16: ...ill appear This means the node did not respond to the base station which could indicate the node is not in idle mode or it may be on another frequency If Add Node Anyway is selected it will associate...

Страница 17: ...dth and maintaining excellent noise performance The first stage is an analog fixed frequency anti aliasing filter with 3 dB attenuation at 800 Hz and 6 18 dB attenuation at 1500 Hz The second is a use...

Страница 18: ...High Pass Filter Values 4 2 Calibration Configuration Each node is calibrated at the factory and stores its linear calibration coefficients in nonvolatile memory These coefficients are applied by the...

Страница 19: ...e will save power in this state without user intervention until the beacon returns Within two minutes of the beacon returning the node will automatically begin sampling and transmitting data again Dia...

Страница 20: ...est Result 0 no errors unit 32 Internal Temperature Valid range 40 to 125 C unit 8 Celsius Low Battery Indicator 0 good 1 low 2 critical sensor will stop sampling unit 8 External Power 0 not connected...

Страница 21: ...e node will automatically re enter the sample mode it performed last with all current settings Disable User Inactivity Timeout to avoid the node automatically changing states Check Radio Interval Whil...

Страница 22: ...ng mode by pressing and holding the start button until the LED light turns blue Single node From Devices select Node Sampling Apply and Start Network to begin collecting data from a single wireless se...

Страница 23: ...he WSDA gateway Each beacon contains a UTC timestamp allowing nodes to align their collected data within an accuracy of 50 us Each node will also buffer data and transmit this data in time slots alloc...

Страница 24: ...rformance in environments where packet error rate is as much as 50 Allows for operation in situations where the node and gateway move in and out of range with each other Potential for higher latency L...

Страница 25: ...lue from the window and dividing by the RMS of the window Peak to Peak is calculated by subtracting the smallest value from the window from the largest value Velocity IPS or m s The RMS of the IPS is...

Страница 26: ...s that the derived period must be at least 32 times as long as the sample period Burst is not limited by this restriction because the minimum burst size is 100 samples 5 4 2 Chunks Windows can encompa...

Страница 27: ...lower frequencies is to reduce the sample rate 5 4 4 Incoherence Derived channels are most accurate when the window time is a multiple of the period of the input signal meaning that the window is coh...

Страница 28: ...iodic intervals This operation allows longer battery life and increased network sizes in applications where continuous monitoring is not required Event Triggered Collect data continuously at a fixed s...

Страница 29: ...OEM USER MANUAL 5 6 Output Operation There are three options for managing data acquired from the G Link 200 OEM The user can transmit collected data log the data to flash memory or do both Figure 22...

Страница 30: ...ical analysis and advanced algorithm development with the integrated MathEngine interface Leveraging the open source API SensorCloud can also be used to collect data from other LORD Sensing sensor pro...

Страница 31: ...w is for logistic management of the SensorCloud account such as changing the log in password accessing user email and reviewing billing information CSV Uploader The data upload feature enables data fr...

Страница 32: ...ime zone and more MathEngine is used to analyze sensor data Functions include the ability to filter out frequencies smooth out noisy data perform math operations such as Fast Fourier Transforms FFTs a...

Страница 33: ...200 OEM USER MANUAL Figure 26 MathEngine View Figure 27 FFT Graph in SensorCloud For more information about SensorCloud features and navigation refer to the SensorCloud website or contact LORD Sensin...

Страница 34: ...nt reading This format provides an easy way to organize many sensors and networks and it allows the information to be displayed in the most appropriate layout Figure 28 Viewing Data 6 2 2 Navigating G...

Страница 35: ...select and configure it in the Channels and Settings left sidebar menu Under Channels the channel s for the widget can be enabled and disabled Figure 29 Widget Settings Menu 6 2 4 Time Series Widget...

Страница 36: ...MANUAL 6 2 5 Exporting Data Files To export data to a csv file select the Export Data button on the Time Series widget Export name the document save to the preferred location on the host computer Fig...

Страница 37: ...ized outdoor enclosure There are 4 mounting holes on the G Link 200 OEM for 2 56 UNC screws The node can be mounted in any orientation but it is recommended that it is mounted in a way that optimizes...

Страница 38: ...unting Height of the node to allow a clearer LOS path to the gateway Height above the ground is also important because reflections off of the ground can interfere at the receiver Generally the higher...

Страница 39: ...figure menu and is highly dependent on the physical environment surrounding the devices 1 Select the node name Range Test Figure 34 Range Test Menu 2 RSSI is a measure of signal strength between the n...

Страница 40: ...6 Data Type Menu Float 4 Bytes The node applies calibration coefficients locally and reports measurements as floating point values Int24 3 Bytes The node sends its 20 bit measurements as signed 24 bit...

Страница 41: ...35 G Link 200 OEM USER MANUAL 8 Troubleshooting 8 1 Troubleshooting Guide...

Страница 42: ...ample or sleep state 2 4 node is out of range Perform a bench test with the node in close proximity to the gateway to verify they are operational For range test and installation recommendations The sy...

Страница 43: ...ll also be flashing the sampling mode code If the node is not sampling activate it in the software or with a sample on start up boot sequence 3 4 sensor is not connected correctly Verify sensors conne...

Страница 44: ...ng manuals accessories cables etc with the RMA number clearly printed on the outside of the package Removable batteries should be removed and packaged in separate protective wrapping Please provide th...

Страница 45: ...39 G Link 200 OEM USER MANUAL 9 Specifications 9 1 Physical Specifications Dimensions 38 1 mm x 6 5 mm x 29 mm Mounting 4 x 2 56 UNC Weight 8 17 grams Conformal Coating Humiseal 1B31...

Страница 46: ...figurable Integrated Temperature Channel Measurement range 40 C to 85 C Accuracy 0 25 C over full range Sampling Sampling modes Continuous periodic burst event triggered Output options Acceleration Ti...

Страница 47: ...wer setting and the supply voltage Repeated exposure to 2x full scale can result in permanent damage 9 3 Mechanical Shock Limits The accelerometers used by the G Link 200 are sensitive instruments tha...

Страница 48: ...ndent on the operational parameters such as sample mode and rate More active channels and higher sample rates equate to decreased battery life The G Link 200 OEM contains internal non rechargeable lit...

Страница 49: ...gured to operate on 16 separate frequencies ranging from 2 405 GHz to 2 480 GHz Following the 802 15 4 standard these frequencies are aliased as channels 11 through 26 For all newly manufactured nodes...

Страница 50: ...ions Technical Support sensing_support LORD com Phone 802 862 6629 Live Chat is available from the website during business hours 9 00 AM to 5 00 PM Eastern Time US Canada 11 2 Sales Support Products c...

Страница 51: ...oud Pricing http sensorcloud com pricing MathEngine Overview http www sensorcloud com mathengine LORD Sensing Wireless Sensors Network Software Development Kit https github com LORD MicroStrain Sensor...

Отзывы: