5
Common Logic Functions
Gas test
- press the buttons (arrow up) and “gas type“ (+) at the same time
- the gas valve is activated for 30 sec.
- a countdown is shown in the display
- press button “gas type“ (+) again to end the test manually
Pump test
- press the buttons (arrow up) and “material type“ (-) at the same time
- the cooling pump is activated for one minute
- a countdown is shown in the display
- press button “material type“ (-) again to end the test manually
Reset adjustments
- press the buttons (arrow up) and “TT Enter“ at the same time
- all secondary parameters are reset to their default values
- if Tiptronic is active, the settings of the current job are reset to their programmed values
- all adjustments of the Extras menu remain unchanged
Master reset
- press the buttons (arrow up) and “Mode“ together for about five sec.
- the display shows “Master Reset“
- the machine is reset completely to factory settings
!!! CAUTION : all Tiptronic jobs are deleted !!!
component
function
associated event
fan (power unit)
on
power modul temperature over 40°C
fan (power unit)
off
power modul temperature below 40°C
fan (cooling system)
on
after detection „welding current on“
fan (cooling system)
off
after welding process, two minutes post-cooling time
pump
on
after detection „welding current on“
pump
off
after welding process, two minutes post-cooling time