Lopi Sturbridge Скачать руководство пользователя страница 23

Operation

2 3

Travis Industries

1 0 0 - 0 1 1 4 2

4 0 2 0 9 1 7

Starting the Stove for the First Time

Fumes from the Painted Surfaces Curing

Burn the heater at a medium setting for approximately one hour the first time.  This will cure the
painted surfaces.  Fumes from the paint curing and oil burning off the steel may occur.  This is
normal.  We recommend you open the window to vent the room.

Condensation

Water may appear on the glass each time you start the heater - this is normal.

Blue Flames

The flames will be blue when first started.  After fifteen minutes the flames will turn a more realistic
yellow and orange color.

Turning the Stove On and Off

OFF

ROOM TEMP

°F

°F

SET TEMPTIMER

MIN

Time

Set

Time

Cancel

A

u

t

o

OF

F

ON

Use this switch to 
turn the main burner 
on and off manually.  

After the pilot has been started...

See the instructions included 
with the remote for details on 
operation.

For systems with wall 
thermostats,  use this switch to 
control the temperature (right 
is hotter, left cooler).  Some 
systems require the on/off 
switch to be on.

See the instructions 
included with the 
remote for changing 
the battery.

Warning: Do not place combustible items on top or directly in front of the heater, even temporarily.

The optional thermostat may start the heater causing a combustible item to ignite.

N o t e :

If the heater turns on and off frequently while using the thermostat, you may want to
adjust the flame height down until it produces just enough heat needed.

Adjusting the Flame Height

+

Your stove has an adjustable flame to tailor the look and heat output to your specific needs.  It is
adjusted by turning the middle dial on the gas control valve.

Flame Height 
Adjustment Knob

Index Mark

Turn counter-clockwise to adjust the flame higher, clockwise to lower.

Содержание Sturbridge

Страница 1: ...building Immediately call gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be pe...

Страница 2: ...enance of your new stove an easier and more enjoyable experience We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your heater Important Informatio...

Страница 3: ...ments 16 Finalizing the Installation Leak Test 17 Pilot Adjustment if necessary 17 Air Shutter Adjustment if necessary 17 Check Flame 18 Glass Removal installation 19 Log Installation 20 Operation Bef...

Страница 4: ...natural gas NG or for propane LP or LPG Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard Direct questions about the type of fuel used to your...

Страница 5: ...or service The pilot flame must contact the thermopile and thermocouple see the illustration to the left If it does not turn the gas control valve to OFF and call your dealer A A A A This unit is not...

Страница 6: ...Low in BTU s 9 900 Steady State Efficiency up to 80 1 AFUE without blower Up to 67 8 Heating capacity will vary depending on the home s floor plan degree of insulation and the outside temperature Effi...

Страница 7: ...uited for the installation Packing List Propane Conversion Kit Log Set 2 Pipe 8 Pipe and 90 Elbow for gas inlet Door Latch Tool to un latch glass frame Touch Up Paint Additional Items Required Vent se...

Страница 8: ...eiling trusses for vertical penetrations You may wish to adjust the stove position slightly to ensure the vent does not intersect with a framing member Fumes and smoke from the paint curing and oil bu...

Страница 9: ...than 48 deep before the ceiling returns to 7 The alcove must be at least 27 3 4 wide The heater must not be placed so the vents below or above the door along the sides of heater or along the back of t...

Страница 10: ...nlet is shown below A manual shutoff valve is required for installation it must be located within 3 of the heater T Handle gas cocks are required in Massachusetts in compliance with code 248CMR Instal...

Страница 11: ...1 25 mm clearance from vent to any combustible vent is 6 5 8 170 mm diameter Use Model GS Direct Vent manufactured by Simpson Dura Vent only or the Chimney Conversion Kit see Addendum 2 Follow the ins...

Страница 12: ...rations Remove the screw with a phillips screwdriver Rotate the adjustment plate clockwise until the correct index hole is to the right of the pivot point Insert the screw into the correct index hole...

Страница 13: ...lculated to the top of the vent on horizontal terminations and to the top of the termination on vertical terminations Vent Height Elbows add 3 75 mm to the length of the vent system Side View 9 5 8 24...

Страница 14: ...Snorkel Termination 14 or 36 add the snorkel height to the vertical height snorkel terminations are used primarily for basement installations AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAAAAAAAA AAAAAA...

Страница 15: ...A AAA AAA AAA AAA AAA AAA AAA AAA AAA 5 feet 10 feet 0 feet 0 feet 2 max 0 feet Restrictor Position 7 Remove Diffuser Plate 20 feet 30 feet 31 max 15 feet 25 feet 2 max 5 feet 10 feet 0 feet 20 feet 3...

Страница 16: ...H Minimum 84 clearance above any grade when adjacent to public walkways or driveways NOTE may not be used over a walkway or driveway shared by an adjacent building I Minimum 48 clearance from any mech...

Страница 17: ...nscrewed gas will come out of this port Clockwise lowers the flame while counter clockwise raises it 6 Let the heater burn for thirty minutes Adjust the air shutter if necessary to achieve the correct...

Страница 18: ...fety hazard Consult your dealer or installer if you suspect an improperly The flames should burn right off the top of the burner ports if they are too blue adjust the air control If the flames are lif...

Страница 19: ...into the hole on the glass frame latch Pull the latch out then up to detach it from the glass frame c Use both hands to grasp the glass frame and lift it up until both the tabs at the bottom disengage...

Страница 20: ...AA AAAA A AA AA A AA AA AA AA AA A Place the rear log so it rests against the ledge on the back wall of the firebox Push on the outer edges to insure it sits up straight Note how it does not cover an...

Страница 21: ...operating the fireplace is attached to the inside of the fireplace here Replace it for easy reference Optional Blower Control On Off Switch This control is used to turn the flame on and off Optional B...

Страница 22: ...U SMELL GAS c Turn the gas control knob to the PILOT position and press the knob in this will allow gas to flow to the pilot light Press the button on the pilot igniter repeatedly until you see the pi...

Страница 23: ...anually After the pilot has been started See the instructions included with the remote for details on operation For systems with wall thermostats use this switch to control the temperature right is ho...

Страница 24: ...you will hear a dull clicking sound This is the valve Blower Snap Disk This part can produce a clicking sound as The appliance may creak with change of temperature THIS IS NORMAL Pilot Flame The pilo...

Страница 25: ...ssive sooting is found the stove will require adjustment Contact your dealer 4 Inspect the firebox for the following Check the burner for cracked plugged or deteriorated holes Check the firebox and ar...

Страница 26: ...ceiver is turned Off One of the two remote control batteries is dead See Starting the Pilot Light See Starting the Pilot Light Turn the ON OFF switch to OFF Use the remote closer to the stove See the...

Страница 27: ...n burners The main burners are switched on and off using the electricity generated by the thermopile The ON OFF switch remote control or thermostat control the circuit to the main burner ON OFF MAIN B...

Страница 28: ...ire Red Optional Remote Control Spark Electrode Pilot Hood On Off Switch Brown Optional Thermostat 7 4 10 9 1 3 Optional Blower Green Hot black Common white Ground green Blower Snap Disk Power In Mole...

Страница 29: ...s information manual provided with this appliance For assistance or additional infor mation consult a qualified installer service agency or the gas supplier WARNING Operation of this appliance when no...

Страница 30: ...e which is the result of but not limited to improper chimney venting installation 7 Exclusions to this 7 Year Warranty include injury loss of use damage failure to function due to accident negligence...

Страница 31: ...left AA AA AA A A AA A A A AA AA AA A A AA AA A AA AA A A AA A A AA A AA A AA A A A A A AA AA AA A A AA A AA A A A AA A AA AAA A A AA A A AA AA A AA AA AA AA AA AA A Slide the air shutters all the way...

Страница 32: ...nsertion 4 8 1 2 The new LP orifice has 1 2 stamped on it The old NG orifice has 48 stamped on it Apply thread sealant to the new orifice and install 5 16 d e 4 Remove the pilot orifice following the...

Страница 33: ...post a b Slotted Screwdriver or T 20 Torx Install the LP regulator Use the screws included with the LP regulator Tighten to approximately 25 Lbs torque c Slotted Screwdriver or T 20 Torx 6 Make the ga...

Страница 34: ...ve the grounding prong from this plug 1 Slide the thermodisk into the holder underneath the firebox Snap Disk Bracket attached to stove Snap Disk 2 Attach the blower following the directions below Sli...

Страница 35: ...o the molex connector on the wiring harness With the outer black casing of the power cord 1 through the hole install the strain relief The strain relief is best installed using pliers to Attach the tw...

Страница 36: ...firebox AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA A A A A A A A A A A A A A AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA AAAAAAAAAA A A A A A A A A A A A A A AAAAAAAA...

Страница 37: ...as possible to prevent them from striking the sides of the cast body AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAAAA AAAAAAAA AAA...

Страница 38: ...6 I D Security Chimneys 6 I D Jackes Evans 6 I D Hart Cooley 6 I D Pro Jet 6 I D Chimney Conversion Kit B 932 Simpson Dura Vent 6 I D Air Jet 6 I D Metal Fab 6 and 7 I D Amer Metals 6 7 I D Metalbesto...

Страница 39: ...Termination 990 90 Elbow Flashing included in 934 Masonry Conversion Kit Make sure the coaxial pipe maintains a 1 clearance to any combustible The vent must be sealed air tight High Temp Silicone Conn...

Страница 40: ...izontal Vent Termination Requirements 16 How this Stove Works 27 Installation Options 6 Items Required for Installation 7 Leaking Gas See Inst on Cover Listing Information 29 Location of Controls 21 L...

Отзывы: