Lopi ProBuilder 24 CleanFace GSR2 Скачать руководство пользователя страница 2

Table of Contents 

© Travis Industries 

5/3/21 - 1529 

PB 24 CF GSR2 Operation (AUST) 

Introduction 

We welcome you as a new owner of a ProBuilder GSR2 gas fireplace. This manual details operation and 
maintenance of this fireplace.  Please familiarize yourself with the Owner's Manual before operating your 
heater and save the manual for future reference. 

Important Information 

No other ProBuilder gas fireplace has the same serial 
number as yours.  The serial number is on the listing 
label that is chained to the gas control valve.  This 
serial number may be needed in case you require 
service. 
Model: 

  ProBuilder 24 CF GSR2 

Serial Number: 

 

 

 
Purchase Date: 

 

 

 
Purchased From: 

 

 

 
 

 

 

 
 

 

 

Installation Warnings 

 

Installation requirements are printed in the ProBuilder GSR2 Installation Manual.  All 
requirements in the installation manual must be met. 

 

Failure to follow all of the requirements may result in property damage, bodily injury, 
or even death. 

 

This heater must be installed by a qualified installer who has gone through a training 
program for the installation of direct vent gas appliances. 

 

This appliance must be installed in accordance with all local codes if any; if not, 
follow ANSI Z223.1 and NFPA 54(88).

 

In Australia follow AS/NZS 5601.1. 

 

In Manufactured or Mobile Homes must conform with Manufactured Home 
Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard 
is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS 
A225.1.  This appliance may be installed in Manufactured Housing only after the 
home is site located. 

 

The fireplace is designed to operate on natural gas, or propane (LP).   

 

All exhaust gases must be vented outside the structure of the living area.  
Combustion air is drawn from outside the living-area structure. 

 

Notify your insurance company before hooking up this fireplace.   

 

Do not place articles on or against this appliance. 

 

Do not use or store flammable materials near this appliance. 

 

Do not spray aerosols in the vicinity of this appliance while it is in operation. 

 

Do not modify this appliance 

 

Servicing shall be carried out only by authorized personnel.

 

Содержание ProBuilder 24 CleanFace GSR2

Страница 1: ...ot touch any electrical switch do not use any phone in your building Immediately call gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier...

Страница 2: ...by a qualified installer who has gone through a training program for the installation of direct vent gas appliances This appliance must be installed in accordance with all local codes if any if not fo...

Страница 3: ...Transmitter Battery Installation 14 Child Proof Feature 14 Normal Operating Odors 15 Power Outages 15 Glass Frame Removal and Installation 15 Glass Removal 17 PB 24 CleanFace Log Installation 19 Inst...

Страница 4: ...afety hazard Direct questions about the type of fuel used to your dealer Check for a label on the flame adjust knob on the gas control valve this is the best place to check You may also check for a la...

Страница 5: ...dealer for service Instruct everyone in the house how to shut gas off to the appliance and at the gas main shutoff valve The gas main shutoff valve is usually next to the gas meter or propane tank and...

Страница 6: ...iance PROGRAMMING THE REMOTE The SIT GSR2 remote may be programmed to disable the thermostat or any of the modes flame height blower light Standing Pilot or auxiliary power input This allows you to ta...

Страница 7: ...n the battery box IFC will beep 3 times Press the ON button on the transmitter IFC will beep 3 times Figure 2 NOTE If power is cut off to the IFC for an extended period of time you may need to re sync...

Страница 8: ...Burner turns off regardless of transmitter settings REMOTE middle position Burner is controlled by the transmitter NOTE When the battery holder switch is turned to ON or OFF the mode settings will rem...

Страница 9: ...day window Each time the burner is turned on the 7 day timer resets If the burner is not engaged within the 7 day window the pilot will automatically revert to IPI mode and turn off to conserve fuel T...

Страница 10: ...and easily Display Overview The transmitter display has four main sections see Figure 3 Figure 3 Listen for the Beep Each time you press a button on the transmitter that controls the fireplace a beep...

Страница 11: ...ve the target temperature see Figure 6 below Flame height will be adjusted up or down to allow operation without turning the burner on and off also called smart modulation To adjust the target tempera...

Страница 12: ...play the 7 settings from OFF to HI for full on NOTE Flame height may not be adjusted if operating in Smart Thermostat setting Figure 9 Blower Speed The blower may be controlled using the up and down b...

Страница 13: ...t F and Celsius C Low Battery Indicator Transmitter Batteries The transmitter has a battery level indicator When it indicates low battery voltage see Figure 11 below install three new AAA alkaline bat...

Страница 14: ...using the locking tabs to ensure a good electrical connection Battery Installation Install 4 AA batteries into the battery holder see Error Not a valid bookmark self reference below These batteries ac...

Страница 15: ...Glass Frame Removal and Installation A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children an...

Страница 16: ...16 Operation Travis Industries 5 3 21 1529 PB 24 CF GSR2 Operation AUST Replacement Barrier Part 24 ProBuilder 250 05282 Bottom hook engages this slot in bracket Top hook engages this slot in bracket...

Страница 17: ...Maintenance 17 Travis Industries 5 3 21 1529 PB 24 CF GSR2 Operation AUST Glass Removal Replacement Glass Frame Part 24 CF ProBuilder 250 05285...

Страница 18: ...es 5 3 21 1529 PB 24 CF GSR2 Operation AUST The latch can come loose from the glass frame anchor This occurs when it is turned 1 4 turn when it is disengaged Follow the directions below to re install...

Страница 19: ...gas control valve is OFF and the heater is cool prior to conducting service Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with thi...

Страница 20: ...1 1529 PB 24 CF GSR2 Operation AUST Installation Log 1 Log 1 has two holes that fit over two pins on the back burner see photos below Place the log in place and push it back The log straddles the burn...

Страница 21: ...ttom burner Slide the log backward until it contacts the sloped portion of the burner Make sure the log does not block any burner holes Log 3 Log 3 has a groove in the bottom of the right side The gro...

Страница 22: ...B 24 CF GSR2 Operation AUST Log 4 Log 4 has 2 channels that align the log with the log grate Place the log as shown below Front View Log 5 Place log 5 as shown below The hole on the bottom of log 5 fi...

Страница 23: ...tom of log 6 fits over the pin on Log 5 The charred end points towards the center of the burner Top View Bottom View Log 7 Place log 7 as shown below The charred end of log 7 rests on the burner The r...

Страница 24: ...a notch that aligns the log with the finger of the log grate Log 9 Place log 9 as shown below The hole on the bottom of log 9 fits over the pin on left end of Log 1 The right end of log 9 rests on Lo...

Страница 25: ...pin on the right end of Log 1 and the slotted hole fits on the pin on log 3 The right end of log 10 rests on Log 8 Top View Bottom View 94500620 Oak Log Replacement Part Numbers 94500620 Oak Log Repla...

Страница 26: ...the perforations in front of the log grate Place a thick layer of the ember glass over the perforations making sure to cover all of the holes completely Lightly dress the ember glass with the black t...

Страница 27: ...urther enhance the firebox Place the embers on the firebox floor and the burner Do not place embers over any of the burner holes or air channels Rock Wool Placement All Models The included rock wool i...

Страница 28: ...e glass may be cleaned with a non abrasive cleaner To clean the inside of the glass simply remove the glass frame place it on a non scratching surface and clean the surface Cleaning the Fireplace Use...

Страница 29: ...lbs To replace follow the directions below Shut off gas to the fireplace and let it cool for 15 minutes Remove the barrier screen and glass assembly see page 15 Remove the media tray skirt Locate the...

Страница 30: ...an if necessary Check the gas control valve and the gas lines If damage is found discontinue use and contact your dealer for service Clean the air channels ducts and blower if applicable Inspect vent...

Страница 31: ...eater The remote control receiver is turned Off Remote or receiver batteries are dead See Starting the Pilot Light See Starting the Pilot Light Turn the ON OFF switch to ON Use the remote closer to th...

Страница 32: ...not operate appliance with the glass front removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person PB 24CF Part Numbers GLASS w FRAME 250 05285 SCRE...

Страница 33: ...nce 33 Travis Industries 5 3 21 1529 PB 24 CF GSR2 Operation AUST Wiring Diagram Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous o...

Страница 34: ...Travis Industries 5 3 21 1529 PB 24 CF GSR2 Operation AUST Safety Label The safety listing label is attached to the operating tag chained to the heater near the gas control valve A copy is shown belo...

Страница 35: ...nts lack of proper and regular maintenance damage incurred while the appliance is in transit alteration or act of God 8 This 7 Year warranty excludes damage caused by normal wear and tear such as pain...

Страница 36: ...2 Installation Warnings 2 Location of Controls 8 Low Battery Indicator 13 Maintaining Your Heater s Appearance 28 Normal Operating Odors 15 Pilot Fuel Conservation Timer 9 Power Outages 15 Remote Con...

Отзывы: