Installation
(for qualified installers only)
15
© Travis Industries
12/27/2018 - 1440
Berkshire GSR2 3-Sided
Horizontal Termination with One 90° Elbow
YOU MUST PUT A MINIMUM 2’ VERTICAL SECTION (3’ FOR LP)
ON TOP OF THE STOVE BEFORE ELBOW
•
If using a Snorkel Termination (14” (356mm) or 36” (915mm)) add the snorkel height to the vertical
height (snorkel terminations are used primarily for basement installations).
•
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.
5 feet (1.5m)
10 feet (3m)
15 feet (4.5m)
19' max (5.8m)
0 feet
5 feet (1.5m)
0 feet
0 feet
5 feet (1.5m)
10 feet (3m)
15 feet (4.5m)
Restrictor Position # 5
NOTE:
Restrictor positions are based
upon lab tests. The ideal
restrictor position may vary
slightly, especially when the
termination is near a
demarkation line.
Restrictor
Position # 1
10 feet (3m)
15 feet (4.5m)
20 feet (6m)
24 ' max (7.3m)
0 feet
5 feet (1.5m)
10 feet (3m)
15 feet (4.5m)
20 feet (6m)
24 ' max (7.3m)
19' max (5.8m)
NOTE:
Horizontal sections require a 1/4" (0.250mm)
rise every 12" (305mm) of travel.
NATURAL GAS: Min. 2' (0.61m) Section Required
PROPANE (LP): Min. 3' (0.915m) Section Required