NOTE:
Dies need not to be fully closed to
achieve correct swage dimension. In fact,
some dies are designed to maintain gap
while under pressure. 5/16”, 3/8”, 7/16", and
1/2" sleeves require two “hits” to crimp. Half
the sleeve length is swaged per “hit.”
MAINTENANCE:
1. Change hydraulic oil every 2000 hours
(approximately 6 months) and more
frequently if it is being operated in dusty
environments.
USE ONLY
ENERPAC
HF-101 HYDRAULIC OIL (PART
NUMBER #4-54HS).
2. Periodically check hydraulic oil. It must
be kept at a level of 2 inches below the
frame.
3.
To control excess leakage, tape all joints
with Teflon tape.
DO NOT USE LIQUID
PIPE SEALANT.
It can damage the unit
and will void warranty.
TROUBLE SHOOTING
TIPS:
1.
Problem:
Operation seems erratic.
Solution:
Check all electrical connection.
2.
Problem:
Hydraulic system is leaking.
(A small amount of oil residue is common).
Solution:
Try simply tightening the fittings.
(Careful not to over-tighten)
WARNINGS:
1. The Locoloc® #5-H Hydraulic is
designed for steady operation up to a
maximum of 6 hours per day.
2. It is the responsibility of the customer
to comply with all applicable health and
safety regulations.
3. Only operate with 110 V AC fused for 30
AMP overload protection.
4. The high pressure of this unit (60,000
PSF) imposes certain conditions which,
if ignored, can be dangerous:
•
All fittings, hoses, gauges, etc.,
must be proven for 10,000 PSI
(60,000 PSF) operation.
•
Use only Enerpac hydraulic oil.
Most hydraulic oils are designed
for low PSI systems.
TO SET PRESSURE:
Always make sure the die set is in the die
shoe before turning the unit on.
1. Plug the machine into a 120 volt 60Hz
outlet. The LCD display backlight will be on
and in the auto mode. Ram is home.
2. Press the green start button to power
up the hydraulic pump. Set pressure by
the upper switch (left hand). This will be
an approximate pressure. You should
adjust the pressure via the gauge reading
obtained by the gauge mounted on the front
of the hydraulic pump unit.
3. The die shoe and the die set should be
mounted and tightened before the next
step.
TO OPERATE:
1. Set pressure. (See Table “A” for correct
pressure.) For dependable swaging, we
highly
recommend using only Locoloc
®
oval and stop sleeves.
2. Position sleeve correctly on cable.
3. Place assembly into die.
4. Depress the foot pedal.
Keep fingers away from swaging area.
5. Press will automatically cycle. Ram will
come down until it reaches the pressure set
on the LCD display, then the ram will return
to the retracted position, ready for another
cycle.
6.
To turn unit off, press the red stop button.
To restart, press the green start button. If
some time has gone by, depress the foot
switch then press the start button again.
This allows the unit to shut-down safely.