18
LOOK-C INSTRUCTIONS
3 =
RG59
A
Coax
A
MDS/
BDU
MDS/
BDU
Coax
A
A
A
0 < Distance ≤ 30m
30 ≤ Distance ≤ 50m
50m ≤ Distance ≤100m
General Install
Shielded Cable For Noisy Environment Install
Distance ≤ 100m
Manufacturer
Recomended
WES Cables
Application:
Distance (A):
RVVP 4*0.5 mm
2
RVV 3*0.5 mm
2
+ SYV75
RVV 3*0.5 mm
2
+ SYV75
CAT5 or CAT6 24AWG
SEC7505
5 =
RG6
It is recomended to use CAT5 Cable for standard installs with shorter lengths. As tested, we found 24AWG CAT5 ample for
up to 50 Meters (see also BDU as a booster). Longer lengths require 20AWG. It is recommended to use shielded cable
for noisy installations when runing cable with other wires (like mains cord, etc.) or steel structure buildings, industrial, etc.
It is recomended to use CAT5 or CAT6 Cable for standard installations of shorter lengths and simpler type applications.
Use shielded cable for noisy environments when runing cable with other wires (like mains, etc.) or steel structure buildings, etc.
Distance ≤ 100m
Distance achieved can vary when using different grades and types of cable and connection methods. Below is manufacturers
recommended cables and cables available from WES Australasia (Tested). Resalts may vary depending on application.
4 Wire - Technical Connections
CABLEDISTANCES