background image

 

 

 
 
 

FlashGel

 Power Supply

 

Instruction Manual 

 

 

 

 

 

 

 

 

Lonza Rockland, Inc. 

www.lonza.com 

[email protected] 

Scientific Support: 800-521-0390 

Customer Service: 800-638-8174 

Rockland, ME 04841 

Содержание FlashGel 57024

Страница 1: ...FlashGel Power Supply Instruction Manual Lonza Rockland Inc www lonza com scientific support lonza com Scientific Support 800 521 0390 Customer Service 800 638 8174 Rockland ME 04841...

Страница 2: ......

Страница 3: ...1 Table of Contents Safety Information 2 Maintenance 3 Specifications 4 Introduction 7 Operation Instructions 9 Troubleshooting 12 Ordering Information 15 Warranty and Liability Information 17...

Страница 4: ...powe tive termi re to adhe atory haza power so safety alw ible to una quipment 2 ion user to im or possible arning of po sult in deat posal instruc or utmost p please recy tement e serious in the oper...

Страница 5: ...se contact a qualified service representative or scientific support lonza com Environmental Conditions Ensure the instrument is installed and operated strictly under the following conditions 75 kPa 10...

Страница 6: ...roprocessor controller Timer 1 999 minutes with alarm continuous Safety Device No load detection shrouded plugs and sockets Physical Specifications Terminal Pairs 2 Pairs Display 3 digit LED Construct...

Страница 7: ...e could void the user s authority to operate the equipment It is strongly recommended for the user to read the following points carefully before operating this equipment 1 Read and follow the manual i...

Страница 8: ...ounded AC outlet Avoiding Damage to the Instrument 1 Do not attempt to operate the device if damage is suspected 2 Protect this unit from physical damage corrosive agents and extreme temperatures dire...

Страница 9: ...d FlashGel Camera offers an all in one comprehensive package for fast easy nucleic acid separation Its compact size with two terminal pairs which provide sufficient and accurate output voltages can de...

Страница 10: ...atures 2 electrode pairs allowing for up to 2 FlashGel Cassettes to be run simultaneously saving both time and valuable bench space With a universal voltage rating the FlashGel Power Supply is also de...

Страница 11: ...cates your current parameter If you are setting a value for Voltage the Voltage LED will be lit b Operation Mode After you start the experiment the LED light next to the RUN STOP button will light up...

Страница 12: ...the unit by pressing the ON OFF switch 4 Connect the DC output jacks from the FlashGel Dock or other electrophoresis unit insert the red lead into the red output jack and the black lead into the blac...

Страница 13: ...ill light up 10 Press button again to stop the unit at any time if necessary 11 When the run is completed Press button to terminate a timed run and turn the AC power OFF by the switch on the rear 12 T...

Страница 14: ...correct cords The fuse has blown Replace the fuse Repeated fuse broken Hardware failure Contact Lonza Scientific Support Operation stops Electrophoresis leads are not connected to the power supply or...

Страница 15: ...if the problem persists Er3 Error message Thermal limitation reached Output voltage 10V 1 Check the connections 2 If Er3 error message persists the problem may be caused by internal fan failure Conta...

Страница 16: ...ll flat blade screwdriver into the slot below the ON OFF switch Turn the screwdriver to gently pry open the fuse compartment NOTE The fuse compartment will not open with the power cord in place 3 Pull...

Страница 17: ...y Pack Includes FlashGel Dock and FlashGel Power Supply 57065 FlashGel Camera Pack Includes FlashGel Dock and FlashGel Camera FlashGel Consumable Kits Cat No Description 57063 FlashGel DNA Kit Include...

Страница 18: ...16 Notes...

Страница 19: ...CIATED WITH THIS PRODUCT WHETHER BASED IN TORT CONTRACT STRICT LIABILITY OR ANY OTHER LEGAL THEORY IS EXPRESSLY LIMITED TO REPLACEMENT OF NONCONFORMING PRODUCT OR PAYMENT IN AN AMOUNT NOT TO EXCEED TH...

Страница 20: ...Lonza Rockland Inc www lonza com scientific support lonza com Scientific Support 800 521 0390 Customer Service 800 638 8174 Document 00525706 0812 2 Rockland ME 04841...

Отзывы: