3. Plug the switch with the female end of the provided
power cord and plug the male end to the power outlet.
Rack-mount Installation
The switch can be mounted in a standard 19” rack with
two optional rack mounting brackets and screws, which
are used for rack mounting the unit.
Procedures to rack-mount the switch in the rack:
1. Disconnect all the cables from the switch before
continuing.
2. Place the unit the right way up on a hard, flat surface
with the front facing you.
3. Locate a mounting bracket over the mounting holes
on one side of the unit.
4. Insert the screws and fully tighten with a suitable
screwdriver.
5. Repeat the two previous steps for the other side of
the unit.
6. Insert the unit into the rack and secure with suitable
screws.
7. Reconnect all the cables.
Network Cables
1.
Crossover or straight-through cable
: All the ports on
the switch support Auto-MDI/MDI-X functionality. Both
straight-through or crossover cables can be used to
connect the switch with PCs as well as other devices like
switches, hubs or routers.
2.
Category 3, 4, 5 or 5e UTP/STP cable
: To make a valid
connection and obtain the optimal performance,
appropriate cables corresponding to different
transmitting/receiving speed is required. To choose a
suitable cable, please refer to the following table.
6