background image

FCC Certifications 

This Equipment has been tested and found to comply 
with the limits for a Class A digital device, pursuant to part 
15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful 
interference when the equipment is operated in a 
commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instruction 
manual, may cause harmful interference to radio 
communications. 

Operation of this equipment in a residential area is likely 
to cause harmful interference in which case the user will 
be required to correct the interference at his own 
expense. 

This  device  complies  with  Part  15  of  the  FCC  Rules. 
Operation is subject to the following two conditions: (1) 
this device may not cause harmful interference, and (2) 
this device must accept any interference received; 
including interference that may cause undesired 
operation. 

 

CE Mark Warning 

This equipment complies with the requirements relating to 
electromagnetic compatibility, EN 55022 class A for ITE, 
the essential protection requirement of Council Directive 
2004/108/EC on the approximation of the laws of the 
Member States relating to electromagnetic compatibility. 

Company has an on-going policy of upgrading its 
products and it may be possible that information in this 
document is not up-to-date. Please check with your local 
distributors for the latest information. No part of this 
document can be copied or reproduced in any form 
without written consent from the company. 

Trademarks: 

All trade names and trademarks are the properties of 
their respective companies. 

Copyright © 2011, All Rights Reserved.

 

1

Содержание LCS-GS9116

Страница 1: ...s subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired opera...

Страница 2: ...nsferring larger and high bandwidth needed files faster in an easy way is probable Automatic MDI MDI X crossover detection makes you no need to worry about the cable type by automatically switch the p...

Страница 3: ...IEEE 802 3x Supports NWay protocol for speed 10 100 1000Mbps and duplex mode Half Full auto detection Supports MDI MDI X auto crossover and polarity correction Store and forward architecture filters...

Страница 4: ...ct LEDs LED Status Operation Steady Green The switch is powered on Power Off The switch is powered off Steady Green Valid port connection Blinking Green Valid port connection and there is data transmi...

Страница 5: ...er end into an electric service outlet After the power cord installation please check if the power LED is illuminated for a normal power status Installation This switch can be placed on your desktop d...

Страница 6: ...e unit 4 Insert the screws and fully tighten with a suitable screwdriver 5 Repeat the two previous steps for the other side of the unit 6 Insert the unit into the rack and secure with suitable screws...

Страница 7: ...witch is placed with appropriate ventilation environment A minimum 25mm space around the unit is recommended 2 The switch and the relevant components are away from sources of electrical noise such as...

Страница 8: ...T Category 5 5e or enhanced UTP STP Network Data Rate 10 100 1000 Mbps Auto negotiation Transmission Mode 10 100Mbps Full duplex Half duplex 1000Mbps Full duplex MAC Address Table 8K 16 port 16K 24 p...

Страница 9: ...h Is In Conformity With Standards Results EN 55022 2006 Pass EN 61000 3 2 2006 Class A Pass EN 61000 3 3 1995 A1 2001 A2 2005 Pass EN 55024 1998 A1 2001 A2 2003 Pass IEC 61000 4 2 2001 Pass IEC 61000...

Страница 10: ...onformity With Standards Results EN 55022 2006 A1 2007 Class A Pass EN 61000 3 2 2006 Class A Pass EN 61000 3 3 1995 A1 2001 A2 2005 Pass EN 55024 1998 A1 2001 A2 2003 Pass IEC 61000 4 2 2001 Pass IEC...

Отзывы: