Trouble Shooting for Thermal Fog Generator
For TS-35A (E), TS-34, TS-35A model,
Preface:
After fill chemicals to chemical tank, petrol or gasoline to the fuel tank respectively, install
battery to machine, the brief procedure start up machine as below,
1. Install fogging tube adapter.
2. Push down oil valve.
3. Use left hand hold air pump handle while right hand press down igniter button to
pump slowly, gently.
4. Only after heard 1 or 2 explosion sounds, pull up oil valve, then, pump a little bit
quickly will start up machine.
(Please note: If could not start up, push down oil valve, continue use left hand hold air
pump handle while right hand press down igniter button to pump machine slowly ,
Until after heard 1 or 2 explosion sounds, pull up oil valve, then, pump a little bit
quickly will start up machine, if still could not start up, please repeat this procedure.)
5. After start up, turn solution tap points to “On” position, start spray fog.
6. If want stop spray fog, firstly turn solution tap points to “Clean Solution” position,
release residual pressure inside chemicals tank.
7. Then, turn solution tap points to “Off” position, stop spray fog.
8. Push down oil valve, stop machine.
Please note: We have already fixed well the standard site of the adjust knob of the
carburetor, do not adjust it, if it is really necessary need to increase power, do not increase
more than 3/8 circle.
1. Starting up skill
1.1
Switch off
oil valve,