The maximum test load of framed mono-facial modules:
16
Installation
Method
Module Type
Bolts Mounting
Clamps Mounting
Mounting rails cross the
long frame
Mounting rails cross the long frame
Mounting
rails cross the
short frame
Clamps are
mounted at
the corners
of short
frame
Outer Four-
hole
Inner Four-
hole
1/4L-50 ≤ D
≤ 1/4L+50
250 ≦ D
≦ 350
300 ≤ D
≤ 400
350 ≤ D
≤ 450
400 ≤ D
≤ 500
150 ≤ E
≤ 250
50/54/60/66-
cell
Framed Mon
o-f
acial Modules
LR6-60-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60HV-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60BK-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60PE-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60PH-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60PB-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60MP-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60MPH-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60HPH-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60HPH-***MC ±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60HPB-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60HIH-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60HIB-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60DG-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60PD-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60HPD-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR6-60OPH-***M
+5400
,
-2400 ±2400
/
/
+5400
,
-2400 /
/
±2400
/
LR4-50HPH-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR4-60HPH-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR4-60HPB-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR4-60HIH-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR4-60HIB-***M
±2400
+5400
,
-2400
+5400
,
-2400
/
/
/
/
±2400
/
LR4-66HP-***M
+5400
,
-2400 ±2400
/
/
/
+5400
,
-2400
/
±2400
/
LR4-66HPH-***M
+5400
,
-2400 ±2400
/
/
/
+5400
,
-2400
/
±2400
/
LR4-66HIH-***M
+5400
,
-2400 ±2400
/
/
/
+5400
,
-2400
/
±2400
/
LR5-54HPH-***M
±2400
+5400
,
-2400
/
+5400
,
-2400 /
/
/
±2400
+2400/-1800
LR5-54HPB-***M
±2400
+5400
,
-2400
/
+5400
,
-2400 /
/
/
±2400
+2400/-1800
LR5-54HIH-***M
±2400
+5400
,
-2400
/
+5400
,
-2400 /
/
/
±2400
+2400/-1800
LR5-54HIB-***M
±2400
+5400
,
-2400
/
+5400
,
-2400 /
/
/
±2400
+2400/-1800
LR5-54HNB-***M
±2400
+5400
,
-2400
/
+5400
,
-2400 /
/
/
±2400
+2400/-1800
LR5-54HTH-***M
±2400
+5400
,
-2400
/
+5400
,
-2400 /
/
/
±2400
+2400/-1800
LR5-54HTB-***M
±2400
+5400
,
-2400
/
+5400
,
-2400 /
/
/
±2400
+2400/-1800
LR5-66HPH-***M
+5400
,
-2400 ±2400
/
/
/
+5400
,
-2400
/
/
/
LR5-66HIH-***M
+5400
,
-2400 ±2400
/
/
/
+5400
,
-2400
/
±1800
±1600