Specifications and Ratings 

 

Type 

Parameter

 

LP-40D 

LP-50D 

LP-60D 

LP-70 

LP-80 

LP-100 

Input Voltage (V) 

110/220v 1-Phase 

220v 1-Phase 

220v 3-

Phase 

Cup Capacity max/sev 

(in.) 

Up to .75 

Up to 1.0 

Up to 1.5 

Up to 1.75 

Up to 2.0 

Up to 2.5  

Input KVA/AMPS 

6/17 

6/17 

9/31 

11/36 

11/36 

15/49 

No-load Voltage (V) 

110/220 

110/220 

110/220 

220v 

(1Phase) 

220v 

(1Phase) 

220v 

(3Phase) 

Current Range (A) 

10-40 

10-50 

10-60 

10-70 

10-80 

20-100 

Rated Output Voltage (V) 

100 

100 

120 

120 

125 

130 

Rated Duty cycle (%) 

60 

60 

60 

60 

60 

60 

Efficiency 

85 

85 

85 

85 

85 

85 

Power Factor (Cos0) 

0.93 

0.93 

0.93 

0.93 

0.93 

0.93 

Insulation Class 

Protection Class 

IP21 

IP21 

IP21 

IP21 

IP21 

IP21 

Arc Starting 

HF Arc-

leading 

HF Arc-

leading 

HF Arc-

leading 

HF Arc-

leading 

HF Arc-

leading 

HF Arc-

leading 

Suggest Air Pressure (psi) 

70 

70 

75 

75 

75 

80 

Suggested Air Volume 

(cfm) 

2-4 

2-4 

3-4 

3-6 

3-6 

5-7 

Machine Weight (lbs) 

18 

19 

42 

55 

70 

77 

Size LxWxH (inches) 

15 x 6 x 12 

15 x 6 x 12 

19 x 8 x 14 

21 x 9 x 14 

21 x 9 x 14 

19 x 13 x 

15 

 

Содержание ForceCut 60i

Страница 1: ...Operating Manual for LP 40 50 60D and LP 70 80 100 Plasma Cutters...

Страница 2: ......

Страница 3: ...Setup Instructions Pg 8 14 Main Unit Knob Button Function Pg 15 Assembly of Plasma Cutter Torches Pg 16 18 Basic Plasma Cutter Operation Pg 19 Summary Chart of All LONGEVITY Plasma Cutters Pg 20 21 Fe...

Страница 4: ...ntact us Please take a moment to register your product on our website at www longevity inc com or www lweld com Once again thank you for choosing LONGEVITY as your main welding supplier LONGEVITY Glob...

Страница 5: ...r or replacement of the defective product will be at our option The repaired replaced product will then be returned to the purchaser LONGEVITY Global Inc will cover the return and replacement shipping...

Страница 6: ...anty Period ____________________________ Unit Tested Prior to Shipment By _____________________________ Out of Warranty Service Customers who own machines that are out of warranty and require service...

Страница 7: ...the maintenance and repair in mind by enabling the internal components of the machine to be a simply plug and operate circuitry enabling all mother boards to be simply replaced and swapped out The For...

Страница 8: ...h applicable safety codes Never touch electrodes wires or circuit components with bare hands Wear dry welding gloves when welding The operator must be insulated from the work piece Smoke and gas can b...

Страница 9: ...tion to protect your hearing Ensure that machine is grounded through the power cord or on the machine case Never operate the machine in bare feet or on a wet floor Never switch the machine off while i...

Страница 10: ...rent Range A 10 40 10 50 10 60 10 70 10 80 20 100 Rated Output Voltage V 100 100 120 120 125 130 Rated Duty cycle 60 60 60 60 60 60 Efficiency 85 85 85 85 85 85 Power Factor Cos0 0 93 0 93 0 93 0 93 0...

Страница 11: ...d Main Unit Cutting Torch Ground Earth Clamp Air Regulator with Water Separator and Bracket Air Hose Teflon Tape Consumables 2 piece tips 2 piece electrodes 1 piece gas diffuser 1 piece shield cups Pi...

Страница 12: ...ical plug to the unit Connecting the power plug to the unit is important Please view the proper connection instructions below Wiring Introduction for 220 Volt Danger Read this manual completely before...

Страница 13: ...eter Another method is to check the continuity between the chassis and the wire using a continuity meter If the selected wire is ground the connection between the chassis and the wire will cause the m...

Страница 14: ...green with a yellow stripe The wire may also be just SOLID GREEN Clean the ends of the wires to more easily distinguish the colors The best and safest way to determine which wire is ground is to meas...

Страница 15: ...wire and a ground wire If you are wiring to 110vac your blue wire is neutral brown is hot and the green with yellow or SOLID GREEN is the ground Note Hot Wires May also be WHITE and BLACK if a GREEN...

Страница 16: ...PLASMA CUTTERS www LWELD com 12 www longevity inc com Basic Instalation Insturctions Pictured Model ForceCut 40D and 70D Models Note All Models have the same connections ForceCut 70D...

Страница 17: ...Plasma Cutters www LWELD com www longevity inc com 13 ForceCut 40D...

Страница 18: ...bove and attach the Air Compressor to the inlet and the OUTLET to the INLET on Unit with the provided hose to back of the machine where shown and secure it with a hose tie 2 Set the air compressor to...

Страница 19: ...l lamp goes out Allow the fan to continue to run Once lamp goes out you may resume using the unit 4 Digital Display Displays the approximate amount of amperage set to on the unit 5 2 5 5 0 Auto Second...

Страница 20: ...switch can be positioned on the top the side or the bottom of the torch body Assembly of Consumables for the LP 40D 50D Assemble the consumables as pictured above and described below 1 Insert the ele...

Страница 21: ...ured above and described below 1 Insert the electrode 2 Place the copper tip on the ring ensuring that is seated flat 3 Secure all parts into place by turning the pink ceramic cup clockwise until it i...

Страница 22: ...n with wrench until snug 4 Secure all parts into place by turning the ceramic cup clockwise until it is snug Do not over tighten The torch consumables are now successfully assembled Assembly of 100 AM...

Страница 23: ...onnect the ground clamp to the work piece to be cut 7 Bring the torch tip into contact with your work piece edge or if cutting thick material over a pre drilled pilot hole See Cutting Guideline Table...

Страница 24: ...500 watts ForceCut LP 40D Pilot Arc Plasma Cutters 40 A at 60 or 30 A at 100 230 V Input 30 A at 60 or 25 A at 100 110 V Input 1 2 in 1 2 in 1 4 in 4000 watts ForceCut LP 50D Plasma Cutters 50 A at 60...

Страница 25: ...0 230 V Input 1 1 4 in 1 1 4 in 5 8 in 8000 watts ForceCut LP 80 Plasma Cutters 80 A at 60 230 V Input 1 1 2 in 1 1 2 in 3 4 in 9000 watts MaxArc LP 100 Plasma Cutters 100 A at 60 230 V Input 1 phase...

Страница 26: ...t Technology ForceCut LP 50D Pilot Arc 25 lbs 28 lbs Boxed Pilot Arc Starting Technology 60 Duty at 50A 100 Duty at 40A 110 220 V Input Portable Toshiba Mosfet Technology ForceCut LP 60D 36 lbs 40 lbs...

Страница 27: ...ght Industrial Commercial Fabrication Maintenance Light Construction ForceCut LP 50D Pilot Arc Hobbyist Light Industrial Commercial Fabrication Maintenance Light Construction ForceCut LP 60D Boat Repa...

Страница 28: ...on a flat surface Raise the work piece above the surface to avoid blow back which may burn you or cause fires Real Time Arc Curve Delay When cutting thick materials you must maintain a steady even mot...

Страница 29: ...soned veteran give it a once through and keep it near by in case you someone you know or someone you work with has a question about the use or specifications of your LONGEVITY Plasma Cutter At this po...

Страница 30: ...and pieced together securely before you begin cutting Gouging or piercing can be achieved by simply lowering the amperage output and keeping with the recommended psi Examples on how to achieve the des...

Страница 31: ...successfully execute a clean cut with your LONGEVITY Plasma Cutter you must consider a combination of elements involved in the cutting process The tip of your torch is designed to focus the plasma st...

Страница 32: ...some instances a project may be a very ornate design with different curves and protrusions or the material is too thick to apply a shield or guard to your LONGEVITY Plasma Cutter torch tip In order t...

Страница 33: ...ingly Thin material requires you to turn down the amperage and change to a lower amperage to achieve a narrow kerf Figuring out if you are going too slow or too fast can be a daunting task that really...

Страница 34: ...ng Team and are written with expressed interest of maintain a strong standard in LONGEVITY Global Inc quality to help address topics and answer questions for amateur and experienced users alike Please...

Страница 35: ...e welding machine should be cleaned once a month Keep the machine exterior clean with mild soap and water Do not walk on or store items on the cables or cords Do not jar drop or stack items on top of...

Страница 36: ...n the hose maintain a distance of 1 8 from the torch tip or workpiece If your unit comes with a manual Post Flow 2 5 or 5 0 switch make sure you leave it on 5 0 for more air to pass cooling your torch...

Страница 37: ...ct us at help longevity inc com LONGEVITY Global Inc Toll Free 1 877 LONG INC 1 877 566 4462 Website www longevity inc com Sales sales longevity inc com Customer Service help longevity inc com Dealers...

Отзывы: