background image

Warranty

Long Range Systems, Inc. warrants this product against any defects that are due to faulty material or workmanship for
a two-year period after the original date of consumer purchase.  This warranty does not include damage to the product
resulting from accident, misuse or improper electrical connection. If this product should become defective within the war-
ranty period, we will repair or replace it with an equivalent product, free of charge. LRS will return your product via UPS
ground shipping. All warranty claims must be initiated through our customer service department.

Copyright © August 2009, Long Range Systems, Inc.  All Rights Reserved

This manual contains proprietary information of Long Range Systems, Inc. (LRS) and is intended for use only by its em-
ployees or customers.  None of the material contained herein may be copied, reproduced, republished, downloaded, dis-
played,  posted,  or  transmitted  in  any  form  or  by  any  means,  including  but  not  limited  to,  electronic,  mechanical,
photocopying, recording, or otherwise without the prior written permission of LRS.  Additional copies of this manual may
be obtained by contacting LRS.

Screen displays, keyboard layouts, hardware descriptions, or software are proprietary to LRS and are subject to copy-
right and other intellectual property rights of LRS and shall be treated in accordance with the previous paragraph.

All attempts have been made to make the information in this document complete and accurate.  LRS is not responsible
for any direct or indirect damages or loss of business resulting from inaccuracies or omissions.  Specifications and other
information contained within this document are subject to change without notice.

Long Range Systems, Inc. reserves the right to make changes without further notice to any products herein. LRS, Inc.
makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor
does LRS, Inc. assume any liability arising out of the application or use of any product or circuit, and specifically disclaims
any and all liability, including without limitation consequential or incidental damages. “Typical” parameters that may be
provided in LRS, Inc. data sheets and/or specifications can and do vary in different applications and actual performance
may vary over time. All operating parameters, including “Typicals”, must be validated for each customer application by
customer’s technical experts. LRS, Inc. products are not designed, intended, or authorized for use as components in sys-
tems intended to support or sustain life, or for any other application in which the failure of the LRS, Inc. product could
create a situation where personal injury or death may occur. Should Buyer purchase or use LRS, Inc. products for any
such unintended or unauthorized application, Buyer shall indemnify and hold LRS, Inc. and its officers, employees, sub-
sidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney
fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unau-
thorized use, even if such claim alleges that LRS, Inc. was negligent regarding the design or manufacture of the part, de-
vice or system.

EU DECLARATION OF CONFORMITY

We, Long Range Systems hereby declare under our sole responsibility that the T74USB paging transmitters and on-site
pagers comply with the essential requirements in the European RE&TTE Directive 1999/5/EC of the European Parliament
of the Council of 9 March 1999 on radio equipment and telecommunication terminal equipment and the mutual recog-
nition of their conformity.  The following standards were utilized:

ETS 300 224: 1998

EN 301 489-2: 2002

EN61000-3-2: 1998

EN 61000-3-3: 1995

EN 60950: 1992 with A1, A2, & A3

Long Range Systems

7

T74USB User Manual

XU-0054 100109

Long Range Systems UK Ltd | Link House | Leek Road | Milton | Stoke on Trent | Staffordshire | ST2 7AH | 01782 537000
www.lrspagers.co.uk | www.pagers.co | www.hospitalpagers.co.uk

Содержание T74USB

Страница 1: ... on n www pager net T74USB FCC ID M74T7400 USB Receive Transmit Power 9VAC 8 0 0 4 3 7 4 9 9 6 w w w p a g e r n e t T74USB Paging System Transmitter USER MANUAL Long Range Systems UK Ltd Link House Leek Road Milton Stoke on Trent Staffordshire ST2 7AH 01782 537000 www lrspagers co uk www pagers co www hospitalpagers co uk ...

Страница 2: ...bleOfContents Installation and Setup 2 Set Restaurant ID 3 Repeat Delay 4 High Power Setting 4 Frequency 5 RF Baud Rate 5 Service Questions and Answers 6 Warranty 7 Long Range Systems 1 T74USB User Manual ...

Страница 3: ...nal on the host computer 5 Assign a Name for the new connection 6 Select the COM Port coming from the USB cable 7 Use the following settings Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None 8 Type ECHO1 and press ENTER This echo function will allow you to see what is being typed 9 You are now ready to use the interface Note At any time use the STAT command to view any cha...

Страница 4: ...D type RID x and press ENTER twice X is the Restaurant ID Example To set an ID of 2 type RID 2 and press ENTER twice Long Range Systems 3 T74USB User Manual Example Restaurant ID to 2 HyperTerminal Output Showing ID as 2 Type STAT and press ENTER Status View Showing Restaurant ID as 2 ...

Страница 5: ...er Setting type HWPR x and press ENTER twice X is the Power Setting a value of 1 to 4 Example To set a Power Setting of 3 type HWPR 3 and press ENTER twice Long Range Systems 4 T74USB User Manual Example Repeat Delay ON Status View Showing Repeat Delay ON Example High Power Set to 1 HyperTerminal Output Showing High Power Set to 1 Status View Showing High Power Set to 1 ...

Страница 6: ... change the Baud Rate type RFBAUD x and press ENTER twice X is the value of the Baud Rate at 512 1200 or 2400 The default Baud Rate of Alpha Numeric Pagers is 1200 If the rate on the transmitter is changed the rate of the Alpha Numeric Pagers will also need to be changed Example of Set Frequency PLL to 37420 467 750 MHz HyperTerminal Output Showing Frequency PLL Set to 37420 467 750 MHz Status Vie...

Страница 7: ...g supplies call Long Range Systems at 800 437 4996 Monday through Friday 8 30 am to 5 00 pm Central Time For weekend or night emergencies Long Range Systems has 24 7 live technical support available Please keep in mind that options are limited over the weekend Long Range Systems 6 T74USB User Manual ...

Страница 8: ...cular purpose nor does LRS Inc assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability including without limitation consequential or incidental damages Typical parameters that may be provided in LRS Inc data sheets and or specifications can and do vary in different applications and actual performance may vary over time A...

Отзывы: