MAINTENANCE
- 14 -
8. MAINTENANCE
Good maintenance is the best assurance for safe, economical and zero-malfunction
running of the generator, and it is also good for environment protection.
Engine exhaust gas contains poisonous carbon monoxide.
Maintenance can only be performed after the engine is stopped. If
maintenance must be performed while the engine is running, the working area
must be well ventilated.
Periodic maintenance and adjustment are necessary for keeping the generator in a
good operating condition. Maintenance schedule is as follows:
MAINTENANCE SCHEDULE
Each
use
Firs month or 20
Hrs
(3)
Every 3
months or
50 Hrs
(3)
Every 6
months or
100 Hrs
(3)
Every year
or
300 Hrs
(3)
Check
oil
level
○
Engine oil
Change
○
○
Check
○
Air filter
Clean
○
(1)
Fuel
sediment
cup
Clean
○
Battery electrolyte
level
Check
○
Spark plug
Clean
○
Replace
Valve clearance
Readjust
○
(2)
Cylinder head
Clean
Every 300 Hrs.
(2)
Fuel
tank
and
strainer
Clean
Every two years(2)
Fuel line
Replace
Every two years(2)
(1) Maintain more frequently when the generator is used in dusty areas.
(2) These items should be maintained by an authorized dealer of our company.
(3) If the generator is to be used frequently, maintenance shall be performed as per the
schedule above to ensure long-time normal operation.
Содержание LC2500-J
Страница 1: ......
Страница 6: ...SAFETY INSTRUCTIONS 2 Never smoke when fueling Don t spill when fueling Stop the engine before fueling...
Страница 27: ......