![LONCIN G250D Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/loncin/g250d/g250d_service-manual_1938402045.webp)
Section 4 Disassembly and service
Valve spring free length
Measure the free length of the valve springs.
Standard
Service limit
34~35 mm
32.5 mm
Replace the spring if they shorter than the service
limit.
Valve seat width
Remove carbon deposits from the combustion
chamber. Inspection the valve seats for pitting or
other damage. Measure the valve seat width.
Standard
Service limit
0.8 mm
2.0 mm
If the valve seat width is under the standard, or
over the service limit, recondition the valve seat
Cylinder head
Remove carbon deposits from the combustion
chamber. Clean off any gasket material from the
cylinder head surface.
Check the spark plug hole and valve areas for cracks.
Check the cylinder head for warpage with a straight
edge and a feeler gauge as shown.
Service limit
0.10 mm
Valve stem OD
Inspect each valve for face irregularities, bending
or abnormal stem wear. Replace the valve if necessary.
Measure and record each valve stem OD.
Standard
Service limit
IN
5.468~5.48 mm
5.318 mm
EX
5.428~5.44 mm
5.275 mm
Replace the valves if their OD is smaller than the service limit.
Valve guide ID
Ream the exhaust valve guide to remove any
carbon deposits before measuring.
Measure and record each valve guide ID.
Standard
Service limit
5.50~5.512 mm
5.572 mm
STRAIGHT EDGE
FEELER GAUGE
4-20