IMPORTANT - READ FIRST - IMPORTANT

IMPORTANT FOR FUTURE REFERENCE

Please record this information and retain this manual for the life of the equipment. For Warranty Service 

and/or parts, this information is required.

 

SAFETY PRECAUTIONS

Before installing and operating this equipment be sure everyone involved in its 

operation are fully trained and are aware of all precautions. Accidents and problems 

can result from a failure to follow fundamental procedures and precautions.

The following words and symbols, found in this manual, alert you to potential hazards 

to the operator, service personnel or the equipment. The words are defined as follows:

DANGER:  This symbol warns of an imminent hazard which will result in serious 

injury or death.

WARNING:  This symbol refers to a potential hazard or unsafe practice, which could 

result in serious injury or death.

CAUTION:  This symbol refers to a potential hazard or unsafe practice, which could 

result in minor or moderate injury, or product or property damage.

NOTICE: 

This symbol refers to information that needs special attention or must be 

fully understood even though not dangerous.

 

TO AvOId PROPERTY dAmAgE, PERSONAl INjURY OR dEATh, 
ShUT OFF gAS bEFORE SERvICINg ThE UNIT.

 

TO AvOId PROPERTY dAmAgE, PERSONAl INjURY OR dEATh, 
ChECK All jOINTS IN ThE gAS SUPPlY lINE FOR lEAKS PRIOR 
TO lIghTINg. USE SOAP ANd wATER SOlUTION (bUbblES). dO 
NOT USE AN OPEN FlAmE.

 

A.  ChECK All jOINTS IN FRONT OF (bEFORE) ThE gAS vAlvE 
bEFORE lIghTINg UNIT.

 

b.  ChECK All jOINTS bEYONd ThE gAS vAlvE AFTER ThE 
UNIT IS lIT.

 

TO AvOId PROPERTY dAmAgE, PERSONAl INjURY OR dEATh, 
All gAS jOINTS dISTURbEd dURINg SERvICINg mUST bE 
ChECKEd FOR lEAKS. ChECK wITh A SOAP ANd wATER 
SOlUTION (bUbblES). dO NOT USE AN OPEN FlAmE.

   This product is intended for commercial use only. Not for household use.

   Local codes regarding installation vary greatly from one area to another. 

The National Fire Protection Association, Inc., states in its NFPA96 latest edition that 

local codes are “Authority Having Jurisdiction” when it comes to requirements for 

installation of equipment. Therefore, installation should comply with all local codes.

Model Number                                                     Serial Number                                                  Date Purchased

Содержание ST-4G

Страница 1: ...intenance instructions thoroughly before installing or servicing this equipment NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt and to...

Страница 2: ...G THE OUTSIDE OF THE STEAMER DISCONNECT THE POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT CAUTION ALLOW COOKING CHAMBER T...

Страница 3: ...oduct or property damage NOTICE This symbol refers to information that needs special attention or must be fully understood even though not dangerous To avoid property damage personal injury or death S...

Страница 4: ...Cleaning 13 14 Maintenance 1 5 User Troubleshooting Guide 1 6 Parts Lists Diagrams 17 26 Wiring Diagram 2 7 NATIONAL FIRE PROTECTION ASSOCIATION 60 Batterymarch Park Quincy Massachusetts 02269 NFPA 7...

Страница 5: ...tch steamer READY light 60 minute mechanical timer that initiates steaming with a continuous steaming non timed ON position A simple valve handle drains water from the reservoir at day s end Hidden do...

Страница 6: ...allets or skids can contain splinters and nails Shipping cartons can contain large staples Wear gloves and protective eyewear when opening moving and disposing of shipping containers Uncrating 1 Cut s...

Страница 7: ...rict the flow of air for combustion and ventilation must be removed Do not obstruct the flue cover or rear vents after installation Electrical Supply Connection Provide 115 VAC 60 HZ 1 PH 15 AMP servi...

Страница 8: ...rd for quick disconnect devices for use with gas fuel ANSI Z21 41 CSA 6 9 2 Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disc...

Страница 9: ...downward pitch of at least 1 4 per foot Observe local code regarding air gap spacing and drain connec tions Stand Stacked Units This section is applicable only if you are installing two steamers on t...

Страница 10: ...be flush mounted to a counter All four edges of the bottom of the steamer must be sealed with RTV silicon sealant to the counter if optional 4 inch legs are not used Counter must be made of a noncom b...

Страница 11: ...n burners will ignite only when the timer is in the ON position or in the TIMING position Within 15 minutes or less the READY light will come on indicating that the water has reached its standby tempe...

Страница 12: ...ddle support rail position 4 Close the door With the READY indicator lit you can initiate TIMED STEAMING If you want to steam the food for a certain length of time set the timer for that period The ti...

Страница 13: ...ristles 5 Spray bottle 6 Measuring cup 7 Nylon pad 8 Towels 9 Plastic disposable gloves 10 Funnel CLEANING procedures 1 Exterior Cleaning A Prepare a warm solution of mild detergent as instructed by t...

Страница 14: ...n and allow water to enter steamer compartment b Pour 1 cup of white vinegar or delimer into steamer compartment and shut door c Set timer to 30 minutes and allow steam cleaning to occur d After the 3...

Страница 15: ...sen the lock nut at the base of the latch pin then turn the latch pin 1 4 turn clockwise and tighten the lock nut After adjustment run the unit to test for steam leakage If there is still leakage repe...

Страница 16: ...start up User a Clean probes in unit b Check float probe orientation c Clean drain strainer d Call service technician Steamer does not fill with water User a Is the ON switch depressed b Is the water...

Страница 17: ...MENT TOP COVER 156396 5 TRAY DRIP 094151 6 SCREW TRS HEAD 10 32 x 3 8 QTY 18 004173 7 SHOULDER SCREW DRIP TRAY QTY 2 070467 8 RACK LID SUPPORT RIGHT PAN 156339 9 WELDMENT CAVITY VENT NO VACUUM 145297...

Страница 18: ...ER FLUE 6 PA 13 156472 WELDMENT FLUE STAC 12 13 6 6 6 6 4 7 7 5 3 6 6 ITEM NO PART NUMBER DESCRIPTION QTY 1 156357 RACK LID SUPPORT LEFT PAN 6 PAN 1 6 6 6 6 9 2 12 13 6 6 6 6 6 4 7 5 3 6 6 Item no Des...

Страница 19: ...ram 4 Pan Door Assembly Item no Description Part number 1 PANEL FRONT DOOR ASSY 156392 2 LATCH ASM 156390 3 GASKET DOOR SILICONE 156388 4 PANEL DOOR INSIDE 156387 5 SCREW TRUSS HEAD MACHINE QTY 6 0057...

Страница 20: ...T DOOR 4 HINGE AND PIN TO BE COATED WITH ITEM 13 NEVER SEEZ GREASE 5 15 15 10 9 11 12 14 3 1 4 2 TORQUE 18 20 IN Lbs TYP ALL SCREWS 16 A R 124793 SILICONE ALUMINUM 15 01OZ 073282 LOCTITE 242 14 A R 00...

Страница 21: ...OM ST 4G 6G 21 Diagram Water Drain Systems RIGHT SIDE VIEW...

Страница 22: ...HEXHEAD KEPS 10 32 071256 9 CLAMP HOSE LOW PRESSURE QTY 6 093482 10 HOSE BLACK RUBBER 3 8 ID X 10 LG 505090 11 TEE 1 2 NPT BRASS 013650 12 ELBOW 90 DEG 1 2 MPT X 3 8 139126 13 ELBOW 1 2 NPT TO 3 4 HO...

Страница 23: ...W WASHER 8 32 X 3 8 2 3 144110 SCREW 8 X 1 2 HEX HD SLOT MACHINE SELF ZINC 5 4 096857 SWITCH DOOR 1 5 096841 SCREW 4 40 X 1 4 HEX MS 2 6 156501 FLAME SENSOR 1 7 143559 IGNITER HOT SURFACE 1 8 096826...

Страница 24: ...WER TILT 119855 15 ST 4G 6G W FLOAT 120 VAC HARNESS NOT SHOWN 140182 16 ST 4G 6G W FLOAT 24 VAC HARNESS NOT SHOWN 149880 17 FUSE 6 AMP 144484 ITEM NO PART NUMBER DESCRIPTION QTY 1 156402 PANEL HIGH VO...

Страница 25: ...Assembly Item no Description Part number 1 VALVE GAS 1 2 098458 2 VALVE GAS JOHNSON CONTROLS NAT 098443 3 ELBOW 90 DEG STREET 004185 4 ELBOW 90 DEG 1 2 NPT 008747 5 NIPPLE 1 2 NPT X 3 1 2 BLK 008227...

Страница 26: ...1 4 143976 INFRARED BURNER 1 5 156506 ORIFICE IGNITER 0 104 2 4 1 2 3 5 NOTE 1 4 PAN GAS ORIFICE IS 156508 NAT 0 2000 SIZE 0 092 Parts List Diagram Gas Burner Assembly Item no Description Part number...

Страница 27: ...OM ST 4G 6G 27 Wiring Diagram PDF created with pdfFactory Pro trial version www pdffactory com...

Страница 28: ...PART NUMBER 156071 Rev C 08 13 5925 I 55 South Byram MS 39272 877 2GO LOLO 877 246 5656 Fax 877 504 4073 www getLoLo com 2013 LoLo Commercial Foodservice Equipment All Rights Reserved...

Отзывы: