LOKERMANN GRAND PIPE 270 MULTI Скачать руководство пользователя страница 10

The start current and crater current can be pre-set. This function can compensate the possible crater 
that appears at the beginning and end of the welding. Thus, 4T is suitable for the welding of medium 
thickness plates. 
Pulsed TIG long welding

4T

 

Introduction

 0

           Press and hold the gun switch, Electromagnetic gas valve is turned on. The

                shielding gas starts to flow;

 0

t1

  Pre flow time, adjustment range of pre flow time :0.0~2.0S; 

 t1

    

Striking success, adjustment range of start current: 5~270A;

 t2

 

  

Loosen the gun switch, the output current slopes up from start current; if the 

              output pulse function is turned on, the output current is pulsed; 

 t2

t3

 Output current slopes up to the setting current value; adjustment range of up slope 

              time 0~10.0S ; 

 t3

t4

  Welding process. During this period, the gun switch is loosen;

Note: If the output pulse function is turned on, the output current is pulsed. If the output pulse function 
               is turned off, the output current is the welding current (Iw); 

 t4

    Repress down the gun switch, the output current slopes down to crater current; if the 

               output pulse function is turned on, the slope down current is pulsed; 

 t4

t5

  Down slope time, adjustment rang of down slope time: 0~10.0S;

 t5

t6

  Crater current holds time; adjustment range of crater current: 5~270A;

 t6

   

Loosen the gun switch, stop arc, and keep on argon flowing; 

 t6

t7

  Post flow time, adjustment range of post flow time: 0.0

10.0S;

 t7

 

    Electromagnetic valve is closed and stop argon flowing. Welding is finished.

4.3 

Argon Arc 

Welding 

Operation

4.3.1 

TIG welding

4T operation

 

t

s

0

I

A

Loosen the  switch

t1

t5

t7

Striking success

Stop arc

t3

t4

Base current setting value 

t2

t6

Loosen the  

switch

Repress down the 

switch

Start current

Crater 

current 

Welding current (peak 

current) setting value

Press and hold the welding 

gun switch

4.3.2 

TIG welding 

(2T operation)

 

t

s

0

I

A

Loosen the welding 

gun switch

Press and hold the welding 

gun switch

t1

t5

Striking success

Stop arc

t3

t4

Base current setting value 

t2

Welding current (peak 

current) setting value

5A

Содержание GRAND PIPE 270 MULTI

Страница 1: ...RAND PIPE 270 M U L T I IMPORTANT Read this OPERATOR MANUAL together with PRESCRIPTION AND COMPLIANCE MANUAL before to use this equipment In case of loss one of two parts contact immediately your deal...

Страница 2: ...nt 3 4 Power supply input connection 3 5 Polarity Connection MMA 3 6 Assembling the equipment TIG 4 OPERATION 4 1 Layout for the panel 4 2 Control Panel 4 3 Argon Arc Welding Operation 4 3 1 TIG weldi...

Страница 3: ...ring of the public supply system Consideration should be given to shielding the supply cable of permanently installed arc welding equipment in metallic conduit or equivalent Shielding should be electr...

Страница 4: ...acters such as stable welding arc low tungsten pole loss more welding current narrow and deep weld 3 DC Pulsed TIG has the following characters 1 Pulse heating Metal in Molten pool has short time on h...

Страница 5: ...60 TIG MMA TIG MMA TIG MMA Rated input Power I1max KW 7 5 9 5 7 5 10 2 6 7 9 5 Rated input Current A 19 24 11 15 9 13 Duty Cycle 40 10min 40 270A 60 225A 100 175A 30 250A 60 180A 100 140A 40 270A 60...

Страница 6: ...g machines power supply connects to 110V 460V When the power supply voltage is over the safe work voltage there are over voltage and under voltage protection inside the welder the alarm light will on...

Страница 7: ...accessory codes When GRAND PIPE 270 MULTI welding machines are operated in HF ignition method the ignition spark can cause interferences in equipment near the welding machine Be sure to take specially...

Страница 8: ...dial shown on the display during welding The illustration below shows an overview of the main settings needed for day to day working using the GRAND PIPE 270 MULTI control panel as an example You will...

Страница 9: ...been pressed 7 Pulse frequency Unit Hz Setting range 0 5 200 Factory setting Important Only selectable when pulse key has been pressed 8 Downslope time Unit S Setting range 0 0 10 0 Factory setting 9...

Страница 10: ...n is turned off the output current is the welding current Iw t4 Repress down the gun switch the output current slopes down to crater current if the output pulse function is turned on the slope down cu...

Страница 11: ...the using life of the tungsten electrode and prevent tungsten clipping 3MMA operation if the electrode touches workpiece over two seconds the welding current will drop to the 0 automatically to prote...

Страница 12: ...r watch listen if thearc welding machine has shaking whistle calling or peculiar smell If there is one of the above problems find out the reason and clear it If you can t find out the reason please co...

Страница 13: ...e damaged Repair or change it The earth cable connected unstably Check the earth cable The welding cable is too long Use an appropriate welding cable There is oil or dust on the workpiece Check and re...

Страница 14: ...5 3 Electrical principle drawing...