Страница 1: ...0 QUANTOM Centrifuge User Manual www logosbio com LBSM MD ML QC8S 0001 VQ1712 01...

Страница 2: ...sed in this document are the property of Logos Biosystems Inc 2017 Logos Biosystems Inc All rights reserved The CE mark indicates that this instrument conforms to all applicable European Community pro...

Страница 3: ...Key functions of Control Panel 9 3 2 Door 9 3 3 Setting RPM RCF 10 3 3 1 Setting RPM 10 3 3 2 Setting RCF 11 3 4 Setting Time 11 3 4 1 Setting MIN 11 3 4 2 Setting SEC 12 3 5 Start Stop 12 3 6 Settin...

Страница 4: ...ea during operation Always position the instrument with enough space on each side of instrument to ensure proper air circulation 10 Do not stop the rotor by touching with hand during the instrument is...

Страница 5: ...ttention and warning for electric shock Indicate a hole for manual door opening in case of emergency Attention and warning for rotor coupling and door opening closing Operating Power 110 V 60 Hz 1A Ma...

Страница 6: ...s to ensure that all parts have been included and that no damage has occurred during shipping The warranty does not cover damage that may occur during shipping and handling Any damage claims must be f...

Страница 7: ...6 1 4 Product Description...

Страница 8: ...voltage ratings 110 V 60 Hz or 220 240 V 50 60 Hz is compatible with the instrument s power supply voltage 2 Turn on the instrument by pressing a switch on the right side of the instrument The setting...

Страница 9: ...nto the motor shaft 3 Place the Rotor Locking Nut at the center hole of the rotor To assemble the rotor Rotate the Rotor Locking Nut clockwise until tightly assembled To disassemble the rotor Rotate t...

Страница 10: ...ce Chapter 3 Operation 3 1 Key functions of Control Panel RPM RCF Use to set the rotor speed and for RPM RCF conversion Once KEY_IN RPM LED ON Twice KEY_IN RCF LED ON Down Up Use to adjust each value...

Страница 11: ...hen the door closed and LED is ON when the door opened Action 1 Press the DOOR button to open the door Close the door completely until it clicks into place A DOOR LED is turned on when the door is ope...

Страница 12: ...F button twice RCF MODE is generated by pressing a RPM RCF button twice A Start LED is turned on by pressing RPM RCF button 2 Press the buttons to change input value and press the RPM RCF button again...

Страница 13: ...A SEC LED is turned on 2 Press the buttons to change input value and press the TIME button again for saving When keeping press the buttons for 5 seconds the unit of setting value is changed to 10 sec...

Страница 14: ...s The LED of PROG button and SEC Save is turned on 3 Press to select the program number You are available to save program up to 10 4 Press PROG to complete the saving If you do not touch the PROG for...

Страница 15: ...mergency Door open function when the door button on the control panel is dumb due to the power failure Use this function under the condition of complete stop of rotor running Action 1 Check the instru...

Страница 16: ...ruction if the power is still not turned on Action 1 Separate the AC power Cord at the back of the instrument and push the flat head screwdriver for bring out the fuse case 2 Replace the damaged fuse...

Страница 17: ...amber after every use 2 If the chamber is contaminated dip the cloth in neutral detergent and clean contaminated area Shaft 1 Always make special attention to clean the motor shaft to avoid any imbala...

Страница 18: ...ugh you try to operate again please contact us Error 2 Door If the door is not closed completely this message is appeared Remove the dirt at the door latch and then close the door completely again Che...

Страница 19: ...02 QUANTOM M50 Cell Counting Slides 500 Slides 10 boxes Reagents Q13501 QUANTOM Total Cell Staining Kit 1 kit Q13101 QUANTOM Total Cell Staining Dye 1 x 0 5 mL Q13001 QUANTOM Cell Loading Buffer I 2 x...

Страница 20: ...strument is in original conditions or 2 after 30 calendar days of purchase only replace or repair the Instrument for up to the Warranty Period without issuing a credit In no event shall the Company ac...

Страница 21: ...31 478 4184 Email sales logosbio com USA 7700 Little River Turnpike STE 207 Annandale VA 22003 USA Tel 1 703 622 4660 Tel 1 703 942 8867 Fax 1 517 266 3925 Email sales logosbio com EUROPE 11B avenue...