4.0 There must be a current supply
4.1 Battery specifications
The manufacturer offers two different battery types recommended
for EHS 1000:
Note 1:
Battery life: 300 cycles at 80% = approx. 600 cycles at 50%
Note 2:
Longest battery life obtained when the battery is charged on being
80% discharged. 1 charge = 1 cycle
Dry-charged batteries must be filled with battery acid 37.5% H
2
SO
4
specificgravity 1.28 before they are used for the first time.
Semi-trak
986034
Semi-trak
986036
Tubular cell
986014
Voltage
12V
12V
12V
Capacity
60Ah/5h
74Ah/20h
105Ah/5h
130Ah/20h
113Ah/5h
130Ah/10h
Recommended for
Normal use
Severe daily use
Life in cycles at
80% discharge
Approx. 300
See note 1
Approx. 1200
See note 2
MAINTENANCE
Liquid inspection
Acid level must be min. 5 mm and max. 10 mm above cells.
Add distilled water if necessary.
MAINTENANCE
Poles
Verdigris to be removed from poles regularly.
Poles to be greased after cleaning.
Charge condition to
be measured with
Acidometre, voltmetre or electrical capacity metre
Charging frequency
Daily or as required.
See note 1
At 80% discharged
See note 2
Charging voltage
measured across
poles during charging
15,2V
No. of lifts with correct
usage. Load 500 kg.
At 1600 mm lift:
80
At 1600 mm lift:
155
At 1600 mm lift:
150
Load 1000 kg
At 1600 mm lift
45
At 1600 mm lift
70
At 1600 mm lift
65
Battery dimensions
LxWxH
278x175x190
513x189x223
514x175x230
Battery weight
19,8 kg
39,6 kg
43 kg