background image

8

2.0  There must be a current supply

2.1  Battery specifications

The manufacturer offers three different battery types recommended
for EHL 1004:

Note 1:

Battery life: 300 cycles at 80% = approx. 600 cycles at 50%

Note 2:

Longest battery life obtained when the battery is charged on being 80%
discharged. 1 charge = 1 cycle

Note 3:

Charging voltage of 14.4 V or higher will damage the battery.

Note 4:

The battery can be charged, irrespective of how much it is discharged.
Battery life: 600 cycles at 60%. To avoid shortening the life of the battery, it
should never be discharged to more than 25%.

Dry-charged batteries must be filled with battery acid 37.5% H

2

SO

4

  specific gravity 1.28

before they are used for the first time.

Semi-trak

986034

Tubular cell

986024

Maintenance free

986040

Voltage

12 V

12 V

12 V

Capacity

60Ah/5h

56Ah/5h

50Ah/5h

Recommended for

Normal use

Severe daily use

Where maintenance

work is not desired

Life in cycles at
80% discharge

Approx. 300

-See note 1

Approx. 1200

-See note 2

Approx. 800

-See note 4

Maintenance
Liquid inspection

Acid level must be min. 5 mm and max. 10 mm

above cells. Add distilled water if necessary

None

Maintenance
Poles

Verdigris to be removed from poles regularly. Poles to be greased

after cleaning.

Charge condition to
be measured with:

Acidometre, voltmetre or
electrical capacity metre.

Voltmetre or

capacity metre

Charging frequency

Daily or as required.

-See note 1

At 80% discharged

battery. -See note 2

Daily or as required..

-See note 4

Charging voltage
measured accross
poles during charging

15,2 V

15,2 V

14,2 V

(See note 3)

No. of lifts with
correct usage.
Load 500 kg

175 lifts

170 lifts

170 lifts

Load 1000 kg

50 lifts

50 lifts

50 lifts

Battery dimensions
LxBxH

278x175x190

19,8 kg

271x172x225

21 kg

275x175x190

20 kg

Содержание EHL 1004

Страница 1: ...EHL 1004 EHL 1004 EHL 1004 EHL 1004 EHL 1004 Instruction Manual Instruction Manual Instruction Manual Instruction Manual Instruction Manual Maintenance...

Страница 2: ...manufacturedinaccordancewithsafety directives Among the subjects dealt with in this Instruction Manual are Proper application Physical limitations of the product Risks with improper use Therefore plea...

Страница 3: ...ge 12 V 12 V 12 V Capacity 60Ah 5h 56Ah 5h 50Ah 5h Recommended for Normal use Severe daily use Where maintenance work is not desired Life in cycles at 80 discharge Approx 300 See note 1 Approx 1200 Se...

Страница 4: ...rging voltage for the battery type see point 2 1 For connection and operation see the instructions accompanying the charger The manufacturer recommends a charger of 20 amp capacity During charging the...

Страница 5: ...current circuit 2 5 Battery indicator The battery indicator shows the battery charge in The most accurate reading can be obtained after the battery has been allowed to remain idle for 5 10 minutes Ye...

Страница 6: ...tory set for maximum design load Emergency stop The highlifter has an emergency stop When activating the emergency stop the main current supply is switched off The movement of the forks stops immediat...

Страница 7: ...have self lubricating bearings or are treated with molybde num disulphide grease The correct hydraulic oil is ISO VG 32 containing an additive Wynn s Hydraulic Systems Concentrate The proportion of c...

Страница 8: ...s lower than 10 C if necessary contact your distributor 3 4 Bleeding the hydraulic system With a load of 50 100 kg the forks must be raised and lowered to top and bottom position 2 3 times 4 12Adjustm...

Страница 9: ...y supply Condition of leads and fuses If faults cannot be traced to these sources contact your dealer but BEFOREASKING THE DEALER FORASSISTANCE TRY THE FAULT LOCATION KEY SYMPTOMS AND OBSERVATIONS Pum...

Страница 10: ...c system See point 3 1 3 2 See point 2 3 See point 2 6 See point 2 7 See point 2 6 See point 3 4 Contact the distributor Contact the distributor Contact the distributor Contact the distributor If the...