LED Behavior and Tone 

 

Each electronic lock membrane keypad has a green, red, yellow and blue LED 

 

During general lock use: 

 

Key press 

= 1 RED flash 

 

Supervisor 

= Flash GREEN (2 blink pattern x 9) 

 

User 

= Solid GREEN 

 

Dual Credential Supervisor 

= Alternate RED & GREEN after first credential; flash GREEN (2 blink 

pattern x 9) after secondary PIN 

 

Dual Credential User 

= Alternate RED & GREEN after first credential; solid GREEN after 

secondary PIN 

 

Programming Mode (

after pressing

 ADD SUPERVISOR 

or

 ADD USER) 

= Flash GREEN to RED to 

YELLOW (repeat) 

 

Network or USB Connection 

= Solid BLUE 

 

PC Control Mode 

= Simultaneous flashing of GREEN, RED and YELLOW (repeat) with solid  BLUE 

 

During key lock override: 

 

The cart will make a quiet tone during key lock override.  The tone is a reminder to relock the cart.  A 
failure to lock the cart will result in a greatly diminished battery life. 

 
 

 

Содержание QT CART

Страница 1: ...QT CARTS PROGRAMMING AND TROUBLESHOOTING GUIDE FOR ELECTRONIC OR PROXIMITY LOCKS ...

Страница 2: ...SECTION 1 2 Setting up the Electronic Lock 2 Adding Deleting Users Supervisors 3 Operating the Electronic Lock 4 Cleaning the Keypad 5 Setup Mode Factory Reset 6 LED Behavior and Tone 7 SECTION 2 8 FAQ and Troubleshooting 8 Part 1 Locking and Unlocking 8 Part 2 Battery Questions 8 Part 3 General Questions 9 ...

Страница 3: ...tion of 3 000 unique PIN or card credentials There are 2 categories of credential Supervisor or User A valid Supervisor credential is needed to add and delete other supervisor and or user credentials Best practices for credentials is to have the supervisor code be at least one digit longer than a user code 1 Press LOCK CLEAR 2 Press ADD SUPERVISOR 3 Enter Supervisor PIN code 4 to 14 digits 4 Press...

Страница 4: ...ss ADD SUPERVISOR 3 Enter the new user PIN code 4 to 14 digits or present new user cart credential 4 Press ENTER 5 Press LOCK CLEAR DELETE USER 1 Enter valid supervisor PIN code and press ENTER or Present valid supervisor card credential if equipped 2 Press Hold ADD USER if the credential to be deleted is a user 3 Press LOCK CLEAR 4 Release ADD USER 5 Enter the PIN code to be deleted and press ENT...

Страница 5: ...electronic lock is equipped with a card reader HID Prox or HID iCLASS 1 Present valid card within range of the HID reader DUAL CREDENTIAL If the User or Supervisor requires a dual credential 1 Enter a valid PIN and press ENTER or Present a valid card for HID Prox or HID iCLASS credentials 2 Enter the second credential 4 14 digit PIN 3 Press ENTER NOTE 1 THE SECOND CREDENTIAL MUST ALWAYS BE A 4 14 ...

Страница 6: ... 3984 Cleaning the Keypad To clean the keypad surface apply non acid based cleaner to a clean cotton cloth do not spray cleaner directly on the keypad Wipe down keypad especially the edges of excess cleaner Note The use of excessive cleaner will cause the circuitry to corrode and fail ...

Страница 7: ...mode Note Each electronic lock has a unique setup code The code can be found on the lock computer inside the cart FACTORY RESET If it becomes necessary to erase ALL Supervisors Users and access entries from the electronic lock and reset all settings to the original factory defaults a FACTORY RESET may be performed This function will also remove the quiet functionality of the electronic lock Settin...

Страница 8: ...lash GREEN 2 blink pattern x 9 after secondary PIN Dual Credential User Alternate RED GREEN after first credential solid GREEN after secondary PIN Programming Mode after pressing ADD SUPERVISOR or ADD USER Flash GREEN to RED to YELLOW repeat Network or USB Connection Solid BLUE PC Control Mode Simultaneous flashing of GREEN RED and YELLOW repeat with solid BLUE During key lock override The cart wi...

Страница 9: ...d and will not allow the drawers to close 6 The buttons on my keypad will not work a This problem generally results from a crimped ribbon cable If the lid is lifted or removed for any reason special care should be taken to ensure the ribbon cable stays in the open space towards the front of the lid If it moves back out of the channel it will be pinched between the lid and the top of the cart This ...

Страница 10: ...art 4 How do we put the divider sets in the drawers a The two thick plastic rails in your divider set are the main rails for the dividers they go in the front and back of the drawer The clear plastic runners are the actual dividers These can be left whole or snapped off to size and installed using the joining bracket clear plastic T to fulfill your storage needs 5 My cart will only roll one direct...

Страница 11: ...LogiQuip PO Box 278 Galesburg MI 49053 Page 10 www logiquip com 800 665 3760 888 965 3984 ...

Страница 12: ...LogiQuip PO Box 278 Galesburg MI 49053 Page 11 www logiquip com 800 665 3760 888 965 3984 ...

Страница 13: ...LogiQuip PO Box 278 Galesburg MI 49053 Page 12 www logiquip com 800 665 3760 888 965 3984 SCAN TO DOWNLOAD THE ELECTRONIC VERSION ...

Отзывы: