Logika Technologies Inc.

 

1250B Reid Street, Unit 12, Richmond Hill, ON Canada L4B 1G3 

 

 

HMD-FOC Hot Metal Detector   

Static Mode Fiber Optical Cable   

Operator’s Manual   

 

Revision 1.02 

 

 

 

 

 

 

 

Содержание HMD-FOC

Страница 1: ...Logika Technologies Inc 1250B Reid Street Unit 12 Richmond Hill ON Canada L4B 1G3 HMD FOC Hot Metal Detector Static Mode Fiber Optical Cable Operator s Manual Revision 1 02...

Страница 2: ...ecifications 3 2 3 Operating Principle 3 2 4 Sensitivity Adjustment 3 3 OPTICAL LENS AND CABLE 4 3 1 A1 Lens 4 3 2 B1 Lens 5 3 3 Fiber Optical Cable 5 3 4 HMD Enclosure 6 4 WIRING CONNECTIONS 6 4 1 El...

Страница 3: ...includes a rugged IP66 enclosure protecting state of the art electronics and will withstand the harsh ambient conditions present in heavy industrial environments The HMD ST FOC is used primarily for...

Страница 4: ...teel braided Sensor detect Infrared range HT Model 500 C 1400 C 700nm 1200nm LT model 360 C 1400 C 900nm 1700nm Self testing TEST PIN Protection DC polarity output overload short circuit protection We...

Страница 5: ...com P a g e 4 3 Optical Lens and cable 3 1 A1 Lens Lens housing Cylindrical Stainless Steel with air purge Ambient Temperature 25 C 300 C 13 F 572 F Field of View Target temperature at 700 C No Ring...

Страница 6: ...ng Fiber Optical Cable Lens housing Cylindrical Stainless Steel with air purge Ambient temperature 25 C 300 C 13 F 572 F Field of View 4 5 other views can be special ordered Installation angle 45 Air...

Страница 7: ...ia a 12 pin connector with ground The HMD is supplied with a mating connector at the back of its enclosure and a standard 2 meter cable with a quick connect assembly This cable is also wired with ferr...

Страница 8: ...be used to protect the lens from dust and vapor Purge air cleans the lens reduces maintenance time and prolongs HMD ST FOC s life in dusty or corrosive environments Compressed Air Requirements Must b...

Страница 9: ...returns to its initial setting Sensitivity Adjust the Threshold Level Potentiometer upon installation to determine the base detector signal according to the application requirements As the potentiome...

Страница 10: ...Check HMD s location and make sure the detection field covers hot metal Detector sends false target detect output 1 The sensitivity is set too high Refer to Section 5 2 adjust sensitivity 2 If step 1...

Страница 11: ...echnologies at 1 888 856 4452 1 888 8LOGIKA with the Serial Number of your HMD before you return our product If we are unable to solve the problem by phone or email Logika will provide you with a retu...