background image

60cm/90cm Stainless Steel 
Chimney Hood

L60CHDX17 / L90CHDX17

Instruction / Installation Manual

L60CHDX17

L90CHDX17

L60_90CHDX17_IB_RC_190411_grace.indd   1

11/4/2019   3:52 PM

Содержание L60CHDX17

Страница 1: ...60cm 90cm Stainless Steel Chimney Hood L60CHDX17 L90CHDX17 Instruction Installation Manual L60CHDX17 L90CHDX17 L60_90CHDX17_IB_RC_190411_grace indd 1 11 4 2019 3 52 PM...

Страница 2: ...L60_90CHDX17_IB_RC_190411_grace indd 2 11 4 2019 3 52 PM...

Страница 3: ...g the Grease Filters by Hand 13 Cleaning the Grease Filters in the Dishwasher 13 Carbon Filter Usage 14 Replacing Carbon Filters 14 Changing the Lamps 14 Hints and Tips 15 If Cooker Hood Does Not Oper...

Страница 4: ...pervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by...

Страница 5: ...hood for visible signs of damage Under no circumstances should you use a damaged appliance It could be dangerous Before connecting the appliance to the mains supply make sure that the voltage and fre...

Страница 6: ...heating appliances that depend on the air from the same room WARNING Danger of toxic fumes Great care should be taken when using the cooker hood at the same time and in the same room or area of the ho...

Страница 7: ...enerally sufficient to ensure safe ventilation If the only way of ensuring adequate ventilation is via an open window a window contact switch should be fitted to ensure that the cooker hood can only o...

Страница 8: ...ed beneath the cooker hood and they have different minimum safe distances to the cooker hood select the greater distance Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves...

Страница 9: ...all Internal Chimney Connection Plate for fixing internal chimney on the wall 4 x 30mm Screws X 2 4 x 40mm Screws X 7 Adapter X 1 for reducing outlet diameter from 150 120mm Drill Template Instruction...

Страница 10: ...2 External Chimney 3 Control Panel 4 Aluminium Filter 5 Illumination Control Panel 1 OFF button 2 Motor speed buttons 3 Lamp button 1 2 3 1 2 3 4 5 Product Overview L60_90CHDX17_IB_RC_190411_grace ind...

Страница 11: ...or ordering details Before using the cooker hood in recirculation mode ensure that the carbon filters are in place See Cleaning and Maintenance Air Recirculation The air is drawn in and cleaned first...

Страница 12: ...s switched off at the wall socket and the plug is withdrawn or the fuse from the fused spur connection unit is withdrawn or the mains fuse is disconnected The surfaces and controls are susceptible to...

Страница 13: ...eaners or abrasive all purpose cleaners Oven cleaners Depending on the cleaning agent used cleaning the filters in a dishwasher can cause permanent discolouration to the surface However this will not...

Страница 14: ...are not being used Do not use your product without the grease filters Replacing Carbon Filters It is necessary to install 2 carbon filters in your product Open all the grease filters see page 7 for d...

Страница 15: ...light bulbs Air suction of cooker hood is weak Check aluminium filters Aluminium grease filters should be washed once a month under normal conditions Check air outlet chimney Air outlet chimney shoul...

Страница 16: ...ncy point PBEP 135 Pa Maximum airflow Qmax 347 8 m3 h Air flow at working point highest setting 337 2 m3 h Air flow at working point lowest setting 221 2 m3 h Measured electric power input at best eff...

Страница 17: ...216 6 m3 h Measured electric power input at best efficiency point WBEP 46 8 W Nominal power of the lighting system WL 5 0 W Average illumination of the lighting system on the cooking surface Emiddle 1...

Страница 18: ...External Chimney 3 Main Hood Unit 4 Internal Chimney Connection Plate 5 External Chimney Connection Plate 6 Hanging Plate 1 4 5 6 2 3 Installation Product Overview L60_90CHDX17_IB_RC_190411_grace ind...

Страница 19: ...19 All dimensions shown are in mm 222 20 400 400 395 20 475 600 900 180 575 955 173 40 55 L60_90CHDX17_IB_RC_190411_grace indd 19 11 4 2019 3 52 PM...

Страница 20: ...0mm above electric cookers hobs may be preferable to give more working space under the hood Account should also be taken of the height of the person who will be using the hood most often The person sh...

Страница 21: ...ducting is horizontal it must be laid to slope away at least 1 cm per metre This is to ensure that condensation cannot drain back into the cooker hood If the exhaust air is to be ducted into the open...

Страница 22: ...um flexible hose 4 You can either use the drill template to mark the position of the fixing screws or position the hood on the wall and mark the position A B C D and E as shown 5 Screw the External Ch...

Страница 23: ...r the Internal Chimney and over the hood motor enclosure Adjust the height you want for the Internal Chimney Mark the positions H I J K as shown Drill H I J K holes on marked points by using a 8 mm dr...

Страница 24: ...e you can drop off your waste for recycling please contact your local authority or where you purchased your product Visit Partmaster co uk today for the easiest way to buy electrical spares and access...