•  During installation, maintenance and repair work, the appliance must be disconnected from the 

mains electricity supply. It is only completely isolated from the electricity supply when:
a) it is switched off at the isolator, or
b) the mains fuse is disconnected, or
c) it is switched off at the wall socket and the plug withdrawn, or
d) the fuse of the fused spur connection unit is withdrawn.

•  Do not connect the appliance to the mains electricity supply by a multi-socket unit or an extension 

lead. These do not guarantee the required safety of the appliance (e.g. danger of overheating). This 

appliance may only be used in mobile installations if a risk assessment of the installation has been 

carried out by a suitably qualified engineer.

•  In areas which may be subject to infestation by cockroaches or other vermin, pay particular 

attention to keeping the appliance and its surroundings in a clean condition at all times.

Using at the same time as other heating 

appliances that depend on the air from 

the same room.

WARNING:

  

Danger of toxic fumes.

•   Great care should be taken when using the cooker hood at the same time and in the same room 

or area of the house as another heating appliance which depends on the air in the room. Such 

appliances include gas, oil, wood or coal-fired boilers and heaters, continuous flow or other water 

heaters, gas hobs, cookers or ovens which draw air in from the room and duct exhaust gases out 

through a chimney or extraction ducting.

•  When used in extraction mode, the appliance draws air in from the room in which it is installed 

and

 from neighbouring rooms.

•  If there is insufficient air, an underpressure will occur. The heating appliance may be starved of 

oxygen, impairing combustion.

•  Harmful gases could be drawn out of the chimney or extraction ducting back into the room, with 

potentially fatal consequences.

•  In order to ensure safe operation, and to prevent gases given off by the heating appliances 

from being drawn back into the room when the cooker hood and the heater are in operation 

simultaneously, an underpressure of 0.04 mbar (4 pa) is the maximum permissible in the room.

Содержание L60CHDX13

Страница 1: ...60cm 90cm Stainless Steel Chimney Hood L60CHDX13 L90CHDX13 Instruction Manual L60CHDX13 L90CHDX13...

Страница 2: ......

Страница 3: ...12 Grease Filters 12 Cleaning the Grease Filters by Hand 13 Cleaning the Grease Filters in the Dishwasher 13 Carbon Filter Usage 14 Replacing Carbon Filters 14 Changing the Lamps 14 Hints and Tips 15...

Страница 4: ...in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Accessible parts may become...

Страница 5: ...It could be dangerous Before connecting the appliance to the mains supply make sure that the voltage and frequency details given on the data plate correspond with the on site electricity supply other...

Страница 6: ...ing appliances that depend on the air from the same room WARNING Danger of toxic fumes Great care should be taken when using the cooker hood at the same time and in the same room or area of the house...

Страница 7: ...ilation brick alone is not generally sufficient to ensure safe ventilation If the only way of ensuring adequate ventilation is via an open window a window contact switch should be fitted to ensure tha...

Страница 8: ...re than one appliance is fitted beneath the cooker hood and they have different minimum safe distances to the cooker hood select the greater distance Safety regulations prohibit the fitting of a cooke...

Страница 9: ...Plate for fixing external chimney on the wall Internal Chimney Connection Plate for fixing internal chimney on the wall 4 x 30mm Screws X 2 4 x 40mm Screws X 7 Adapter X 1 for reducing outlet diamete...

Страница 10: ...Recirculation Vents 2 Internal Chimney 3 External Chimney 4 Control Panel 5 Aluminium Filter 6 Illumination Control Panel 1 OFF button 2 Motor speed buttons 3 Lamp button 1 2 3 1 2 3 4 5 6 Product Ove...

Страница 11: ...ptional extra see rear page for ordering details Before using the cooker hood in recirculation mode ensure that the carbon filters are in place See Cleaning and Maintenance Air Recirculation The air i...

Страница 12: ...hed off at the isolator or it is switched off at the wall socket and the plug is withdrawn or the fuse from the fused spur connection unit is withdrawn or the mains fuse is disconnected The surfaces a...

Страница 13: ...ents Powder cleaners cream cleaners or abrasive all purpose cleaners Oven cleaners Depending on the cleaning agent used cleaning the filters in a dishwasher can cause permanent discolouration to the s...

Страница 14: ...roduct even when carbon filterss are not being used Do not use your product without the grease filters Replacing Carbon Filters It is necessary to install 2 carbon filters in your product Open all the...

Страница 15: ...d be in the on position Check light bulbs Air suction of cooker hood is weak Check aluminium filters Aluminium grease filters should be washed once a month under normal conditions Check air outlet chi...

Страница 16: ...chnical Specifications Model no L60CHDX13 L90CHDX13 Extraction Rate m3 h 310 Voltage V 220 240 Frequency Hz 50 Total Power W 145 Lamp 2 40 W Features and specifications are subject to change without n...

Страница 17: ...17 1 Internal Chimney 2 External Chimney 3 Main Hood Unit 4 Internal Chimney Connection Plate 5 External Chimney Connection Plate 6 Hanging Plate 1 4 5 6 2 3 Installation Product Overview...

Страница 18: ...18 All dimensions shown are in mm 222 20 400 400 395 20 475 600 900 180 575 995 173 40 55...

Страница 19: ...at a distance greater than 650mm above electric cookers hobs may be preferable to give more working space under the hood Account should also be taken of the height of the person who will be using the...

Страница 20: ...re strong and airtight Where ducting is horizontal it must be laid to slope away at least 1 cm per metre This is to ensure that condensation cannot drain back into the cooker hood If the exhaust air i...

Страница 21: ...p of unit Bend it a little and insert another end into the hole on the other end of air outlet Do the same of another Outlet Flap If your kitchen is with 120mm hole you need to mount Adaptor onto air...

Страница 22: ...lace the External Chimney over the Internal Chimney and over the hood motor enclosure Adjust the height you want for the Internal Chimney Mark the positions H I J K as shown Drill H I J K holes on mar...

Страница 23: ......

Страница 24: ...ill help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste for recycling...

Отзывы: