Logik L60CHDG10 Скачать руководство пользователя страница 19

19

• 

The electrical safety of this appliance can only be 

guaranteed when continuity is complete between 

the appliance and an effective earthing system 

which complies with current local and national 

safety regulations. It is most important that this 

basic safety requirement is present and tested 

regularly, and where there is any doubt, the 

household wiring system should be inspected by a 

qualified electrician. The manufacturer cannot be 

held liable for the consequences of an inadequate 

earthing system (e.g. electric shock).

• 

For safety reasons, this appliance may only be used 

when it has been fully installed.

• 

Only open the housing as described in the 

instructions. Under no circumstances should any 

other parts of the housing be opened. Tampering 

with electrical connections or components and 

mechanical parts is highly dangerous to the user, 

and can cause operational faults.

• 

Installation, maintenance and repairs may only be 

carried out by an authorised person in accordance 

with current national and local safety regulations. 

Repairs and other work by unqualified persons 

could be dangerous. The manufacturer cannot be 

held liable for unauthorised work.

• 

Faulty components must only be replaced by 

genuine original parts.

• 

During installation, maintenance and repair work, 

the appliance must be disconnected from the 

mains electricity supply. It is only completely 

isolated from the electricity supply when:

a) it is switched off at the isolator, or

b) the mains fuse is disconnected, or

c) it is switched off at the wall socket and the plug 

withdrawn, or

d) the fuse to the fused spur connection unit is 

withdrawn.

• 

Do not connect the appliance to the mains 

electricity supply by a multi-socket unit or an 

extension lead. These do not guarantee the 

required safety of the appliance (e.g. danger of 

overheating). This appliance may only be used 

in mobile installations if a risk assessment of the 

installation has been carried out by a suitably 

qualified engineer.

• 

In areas which may be subject to infestation 

by cockroaches or other vermin, pay particular 

attention to keeping the appliance and its 

surroundings in a clean condition at all times.

Using at the same time as other heating 

appliances that depend on the air from the same 

room.

WARNING:

 Danger of toxic fumes.

• 

 Great care should be taken when using the cooker 

hood at the same time and in the same room or 

area of the house as another heating appliance 

which depends on the air in the room. Such 

appliances include gas, oil, wood or coal-fired 

boilers and heaters, continuous flow or other water 

heaters, gas hobs, cookers or ovens which draw 

air in from the room and duct exhaust gases out 

through a chimney or extraction ducting.

• 

When used in extraction mode, the appliance 

draws air in from the room in which it is installed 

and

 from neighbouring rooms.

• 

If there is insufficient air, an underpressure will 

occur. The heating appliance may be starved of 

oxygen, impairing combustion.

• 

Harmful gases could be drawn out of the chimney 

or extraction ducting back into the room, with 

potentially fatal consequences.

• 

In order to ensure safe operation, and to prevent 

gases given off by the heating appliances from 

being drawn back into the room when the 

cooker hood and the heater are in operation 

simultaneously, an underpressure of 0.04 mbar (4 

pa) is the maximum permissible in the room.

L60_90CHDG10_IB_110524.indd   19

24/05/2011   5:46 PM

Содержание L60CHDG10

Страница 1: ...60cm 90cm Glass Chimney Hood Instruction Installation Manual L60CHDG10 L90CHDG10 L60_90CHDG10_IB_110524 indd 1 24 05 2011 5 45 PM...

Страница 2: ...L60_90CHDG10_IB_110524 indd 2 24 05 2011 5 45 PM...

Страница 3: ...ers by Hand 8 Cleaning the Grease Filters in the Dishwasher 9 Carbon Filter Usage 9 Fitting and Replacing the Carbon Filter 10 Changing the Lamps 10 Hints and Tips 11 If Cooker Hood Does Not Operate 1...

Страница 4: ...YT 310 1000 20 3 9 x 22 mm YSB Screw 2 Used for mounting chimney connection plate P N YT 310 1000 16 3 5 x 9 5 mm RYSB Nickel Screw 2 Used for mounting internal chimney P N YT 310 1000 10 Instruction...

Страница 5: ...oduct Overview 1 Recirculation Vents 2 Internal Chimney 3 External Chimney 4 Control Panel 5 Aluminium Filter 6 Illumination 7 Tempered Glass 1 2 3 7 6 4 5 L60_90CHDG10_IB_110524 indd 5 24 05 2011 5 4...

Страница 6: ...oking vapours to be ducted away Air Recirculation The air is drawn in and cleaned first by the grease filters and then by a carbon filter The cleaned air is then recirculated back into the kitchen thr...

Страница 7: ...ring meat you may wish to select the highest setting III To turn the motor fan off press the OFF button Hob Lighting The hob lighting can be switched on and off independently of the fan by pressing th...

Страница 8: ...cted The surfaces and controls are susceptible to scratches and abrasions Please observe the following cleaning instructions Only use a damp cloth as water could get into the unit and cause damage Do...

Страница 9: ...f any residues of oil or fat from the now accessible housing to prevent the risk of these catching fire When putting the grease filters back in position ensure that the locking clips are facing down t...

Страница 10: ...the connection channels on the motor and turn the left hand filter clockwise and the right hand filter anti clockwise In order to remove filters turn the left hand filter anti clockwise and the right...

Страница 11: ...n position Check lamps have not blown Air suction of cooker hood is weak Check aluminium filter Aluminium grease filter should be washed once a month under normal conditions Check air outlet chimney A...

Страница 12: ...el no L60CHDG10 L90CHDG10 Extraction Rate m3 h 250 Voltage V 220 240 Frequency Hz 50 Total Power W 160 Lamp 2 25 W Features and specifications are subject to change without notice L60_90CHDG10_IB_1105...

Страница 13: ...imney Connection Plate 2 Internal Chimney 3 External Chimney 4 Cooker Hood Main Unit 1 2 3 4 360 450 598 898 412 400 20 500 258 5 213 20 80 Min 575 Max 955 All dimensions shown are in mm L60_90CHDG10_...

Страница 14: ...that a distance greater than 650 mm above electric cookers hobs may be preferable to give more working space under the hood Account should also be taken of the height of the person who will be using t...

Страница 15: ...s are strong and airtight Where ducting is horizontal it must be laid to slope away at least 1 cm per metre This is to ensure that condensation cannot drain back into the cooker hood If the exhaust ai...

Страница 16: ...C D E Mounting the Cooker hood 4 Using two of the 5 5 x 60 mm YSB screws screw into the wall fixings leaving a 5 mm gap between the bottom of the screw head and the wall Hang the appliance on the two...

Страница 17: ...l chimney section to the chimney connection plate using the two 3 5 x 9 5 mm screws 11 Fit the external chimney section with the rear cut out at the bottom end over the internal chimney section and sl...

Страница 18: ...are able to use it safely recognising the dangers of misuse Correct Use Never use an open flame beneath the cooker hood To avoid the danger of fire do not flamb or grill over an open flame under the...

Страница 19: ...unit is withdrawn Do not connect the appliance to the mains electricity supply by a multi socket unit or an extension lead These do not guarantee the required safety of the appliance e g danger of ov...

Страница 20: ...spare parts and accessories with this appliance Ventilation can be maintained by air inlets which must not be blocked in windows doors and outside wall vents or by other technical measures such as ens...

Страница 21: ...symbol on the product or in the instructions means that your electrical and electronic equipment should be disposed at the end of its life separately from your household waste There are separate coll...

Страница 22: ...L60_90CHDG10_IB_110524 indd 22 24 05 2011 5 46 PM...

Страница 23: ...L60_90CHDG10_IB_110524 indd 23 24 05 2011 5 46 PM...

Страница 24: ...L60_90CHDG10_IB_110524 indd 24 24 05 2011 5 46 PM...

Отзывы: